121 resultados para rhodamine B dye
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Toxic baits are the most used control method for leaf-cutting ants due to their high effectiveness and because they are considered the safest for humans. Taking into account that the importance of leaf-cutting ants as pests, knowing the process by which dispersal and worker contamination is achieved becomes essential to understand several aspects about the functioning of a bait-borne AI (active ingredient) used in toxic baits. It has been established that an effective toxic bait should have a delayed- action AI, but its dispersion among the different sizes of workers is unknown. Workers of different sizes are involved in quite different tasks such foraging, cultivation of symbiotic macrofungus or control of deleterious microfungi. Therefore, we prepared a toxic bait containing the delayed-action AI sulfluramid and a dye (Rhodamine B) as an AI tracer in order to study dispersal and contamination in colonies, evaluated at different periods and in relation to different workers' sizes. Both field and laboratory colonies were evaluated. The great level of contamination, about 50% at 24 hours, in all sizes of workers demonstrates that worker contact with toxic bait is intense within this period. The distribution in field and laboratory colonies was similar. This contamination pattern is probably enough to cause the colony to die because of contamination of smaller workers, leading to the loss of control of the aggressive microfungi, which can quickly overgrow the symbiotic fungus culture. The dispersal dynamics of AI in leaf-cutting ant workers is important for investigations on the mode of action of this insecticide in the colony, and as a reference in future studies, such as those attempting to reduce the concentration of AIs in baits to reduce their environmental impact, or for facilitation of new AI screening.
Resumo:
The aim of this study was to determine the effect of the exposure of different endodontic materials to different dye solutions by evaluating the optical density of the dye solutions. Seventy-five plastic tubes were filled with one of the following materials: AH Plus, Sealapex, Portland cement, MTA (Angelus and Pro Root) and fifteen control plastic tubes were not. Each specimen of material and control was immersed in a container with 1 ml of each dye solution. A 0.1 ml-dye solution aliquote was removed before immersion and after 12, 24, 48 and 72 hours of each specimen immersion to record its optical density (OD) in a spectrophotometer. Statistical analysis was performed with ANOVA and Tukey tests (5%). No significant difference was found among any of the solution OD values for AH Plus cement. Portland cement promoted different OD values after 12 hours of immersion. MTA-Angelus cement presented different OD values only for 2% rhodamine B and the MTA-Pro Root cement presented different OD values in all 2% rhodamine B samples. Sealapex cement promoted a reduction in the India Ink OD values. Dye evaluation through OD seems to be an interesting method to select the best dye solution to use in a given marginal leakage study.
Resumo:
Background. The aim of this study was to evaluate the influence of zero-value subtraction on the performance of two laser fluorescence (LF) devices developed to detect occlusal caries. Methods. The authors selected 119 permanent molars. Two examiners assessed three areas (cuspal, middle and cervical) of both mesial and distal portions of the buccal surface and one occlusal site using an LF device and an LF pen. For each tooth, the authors subtracted the value measured in the cuspal, middle and cervical areas in the buccal surface from the value measured in the respective occlusal site. Results. The authors observed differences among the readings for both devices in the cuspal, middle and cervical areas in the buccal surface as well as differences for both devices with and without the zero-value subtraction in the occlusal surface. When the authors did not perform the zero-value subtraction, they found statistically significant differences for sensitivity and accuracy for the LF device. When this was done with the LF pen, specificity increased and sensitivity decreased significantly. Conclusions. For the LF device, the zero-value subtraction decreased the sensitivity. For this reason, the authors concluded that clinicians can obtain measures with the LF device effectively without using zero-value subtraction. For the LF pen, however, the absence of the zero-value subtraction changed both the sensitivity and specificity, and so the authors concluded that clinicians should not eliminate this step from the procedure. Clinical Implications. When using the LF device, clinicians might not need to perform the zero-value subtraction; however, for the LF pen, clinicians should do so.
Resumo:
The aim of this study was to investigate the apical leakage of roots filled by three different gutta-percha techniques: lateral condensation, Tagger's hybrid and E&Q Master. Forty-two extracted single-rooted teeth were used. The coronal part of each tooth was removed and the root received biomechanical preparation using a 60-K file. The roots were randomly divided into three groups according to the technique of filling the root canal: Group I, lateral condensation; Group II, Tagger's hybrid; Group III, E&Q Master. The roots were submitted to dye leakage test with Rhodamine B for 7 days, using vacuum during the initial 30 min. The teeth were sectioned longitudinally and the leakage was measured in a linear fashion from apex to crown. Statistical analysis indicated that lateral condensation and E&Q Master techniques showed lower leakage than Tagger's technique (P = 0.0016). However, statistically no difference was found between lateral condensation and E&Q Master system techniques.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Química - IQ
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciência e Tecnologia de Materiais - FC
Resumo:
Objective: The aim of this in vitro study was to analyze the effect of glass-ionomer cement as a liner on the dentin/resin adhesive interface of lateral walls of occlusal restorations after thermocycling.Materials and Methods: Occlusal cavities were prepared in 60 human molars, divided into six groups: no liner (1 and 4); glass-ionomer cement (GIC, Ketac Molar Easymix, 3M ESPE) (2 and 5); and resin-modified glass-ionomer cement (RMGIC, Vitrebond, 3M ESPE) (3 and 6). Resin composite (Filtek Z250, 3M ESPE) was placed after application of an adhesive system (Adper Single Bond 2, 3M ESPE) that was mixed with a fluorescent reagent (Rhodamine B) to allow confocal microscopy analysis. Specimens of groups 4, 5 and 6 were thermocycled (5 degrees C-55 degrees C) with a dwell time of 30 seconds for 5000 cycles. After this period, teeth were sectioned in approximately 0.8-mm slices. One slice of each tooth was randomly selected for confocal microscopy analysis. The other slices were sectioned into 0.8 nun x 0.8 mm beams, which were submitted to microtensile testing (MPa). Data were analyzed using two-way ANOVA and Tukey test (p < 0.05).Results: There was no detectedstatistical difference on bond strength among groups (alpha < 0.05). Confocal microscopy analysis showed a higher mean gap size in group 4(12.5 mu m) and a higher percentage of marginal gaps in the thermocycled groups. The RNIGIC liner groups showed the lowest percentage of marginal gaps.Conclusions: Lining with RMGIC resulted in less gap formation at the dentin/resin adhesive interface after artificial aging. RMGIC or GIC liners did not alter the microtensile bond strength of adhesive system/resin composite to dentin on the lateral walls of Class I restorations.
Resumo:
The mutagenic activity of garbage originating from a household wax industry was determined by the Salmonella/microsome assay, using the bacterial strains TA100, TA98 and YG1024. The garbage was obtained by sweeping the floor of the factory at the end of the work shift. Organic compounds were extracted by ultrasound for 30 min in dichloromethane or 70% ethanol. After evaporation of solvent, these extracts (HFS: household-wax factory sweepings) were dissolved in DMSO, and were tested for the mutagenic activity at varying concentrations (HFS-ET: 0.08-0.68 mg/plate, HFS-DCM: 0.60-7.31 mg/plate). The colouring agents (pigments) used in the production of the wax were also dissolved in DMSO and tested with the assay. The concentrations tested for each pigment were: Amaranth: 0.46-3.65 mg/plate, Auramine: 0.15-1.2 mg/plate, Tartrazine: 0.46-3.65 mg/plate and Rhodamine B: 0.22-1.82 mg/plate. Both ET and DCM organic extracts had mutagenic activity, especially in the YG1024 strain. The pigments behaved in a similar way, demonstrating that YG1024 was the most sensitive strain for the detection of mutagenicity, and that metabolization increased the activity. Human exposure (occupational and non-occupational) to industrial residues generated during the household-wax manufacturing and packaging process should be monitored, since this type of garbage is normally deposited in the environment without any control. (C) 2004 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)