95 resultados para retention screw
Resumo:
Osseointegrated implants in craniofacial reconstructions improve prostheses retention and stability and comfort and safety for a patient. According to biomechanical principles, the treatment success regarding osseointegration maintenance depends on an adequate surgical technique associated to a retention system that provides favorable tension distribution to implants. Furthermore, patient expectation, esthetics, function, and anatomic limitations must be evaluated during treatment planning. Therefore, the aims of this study were to present available retention systems to implant-supported craniofacial prosthesis and to highlight the advantages, indications, and limitations. A literature review was conducted through a MEDLINE search. Sixteen articles and 2 textbooks met the inclusion criteria and were included in the review. It was concluded that the success of craniofacial rehabilitation with implants depends on an adequate surgical technique and an adequate selection of a retention system.
Resumo:
Objective: Surgical reconstruction and prosthetic obturation are alternatives for the treatment of cleft in the soft palate.Design: The present case reports the rehabilitation of a patient presenting cleft palate with obturator prosthesis associated with implant-supported retention system.Conclusions: The use of ball attachment system improved speech, masticatory efficiency, swallowing, and social behavior of the patient.
Resumo:
The aim of this study was to evaluate the biomechanical behavior of a mandibular distal extension removable partial denture (DERPD) associated with an implant and different retention system, by bidimensional finite element method. Five hemimandible models with a canine and external hexagon implant at second molar region associated with DERPD were simulated: model A, hemimandible with a canine and a DERPD; model B, hemimandible with a canine and implant with a healing abutment associated to a DERPD; model C, hemimandible with a canine and implant with an ERA attachment associated to a DERPD; model D, hemimandible with a canine and implant with an O'ring attachment associated to a DERPD; and model E, hemimandible with a canine and implant-supported prosthesis associated to a DERPD. Cusp tips were loaded with 50 N of axial or oblique force (45 degrees). Finite element analysis was performed in ANSYS 9.0. model E showed the higher displacement and overload in the supporting tissues; the patterns of stress distribution around the dental apex of models B, C, and D were similar. The association between a DERPD and an osseointegrated implant using the ERA or O'ring systems shows lower stress values. Oblique forces showed higher stress values and displacement. Oblique forces increased the displacement and stress levels in all models; model C displayed the best stress distribution in the supporting structures; healing abutment, ERA, and O'ring systems were viable with RPD, but DERPD association with a single implant-supported prosthesis was nonviable.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Purpose: Different surface treatments have been developed in attempts to prevent the loosening of abutment screws. The aim of the current study was to compare the effectiveness of titanium alloy screws with tungsten-doped diamond-like carbon (W-DLC) coating and uncoated screws in providing stability to zirconia (ZrO2) ceramic abutments after cyclic loading. Materials and Methods: Twenty prefabricated ZrO2 ceramic abutments on their respective external-hex implants were divided into two groups of equal size according to the type of screw used: uncoated titanium alloy screw (Ti) or titanium alloy screw with W-DLC coating (W-DLC/Ti). The removal torque value (preload) of the abutment screw was measured before and after loading. Cyclic loading between 11 and 211 N was applied at an angle of 30 degrees to the long axis of the implants at a frequency of 15 Hz. A target of 0.5 x 10(6) cycles was defined. Group means were calculated and compared using analysis of variance and the F test (alpha=.05). Results: Before cyclic loading, the preload for Ti screws was significantly higher than that for W-DLC/Ti screws (P=.021). After cyclic loading, there was no significant difference between them (P=.499). Conclusions: Under the studied conditions, it can be concluded that, after cyclic loading, both abutment screws presented a significant reduction in the mean retained preload and similar effectiveness in maintaining preload. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:1061-1067
Resumo:
The screw-worm Cochliomyia hominivorax (Coquerel), whose larvae develop in wild and domestic animals as well as in man, is one of the major causes of myiasis in Brazil. Sheep raising is expanding in the state of São Paulo, where information about the infestation of screw-worm is necessary for appropriate control measures. The present data were obtained from questionnaires sent to all sheep breeders belonging to 'Associação Paulista de Criadores de Ovinos' - ASPACO (São Paulo State Association of Sheep Breeders). Response reliability was tested by random visits paid to 10.6% of the respondents. The results show that screw-worm is the most frequent ectoparasite in the flocks and is responsible for the greatest economic losses. Its occurrence is strongly associated with flock size, reaching 100% in hocks consisting of more than 500 animals. Infestation is higher in spring and summer and lowest in the fall. The number of cases increases in the presence of some management practices such as tail amputation. Furthermore, several other associations between the indicators surveyed were also found to be significant. The data obtained will permit the elaboration of strategies for the control of this parasitosis.
Resumo:
Retention of particulate organic matter was investigated over a range of water discharges in pool and riffle zones of a tropical stream (Itauna Stream, São Paulo, Brazil). A closed-system leaf release and capture method was used to quantify leaf retention in a 50-m reach of the stream. Instantaneous retention rates (k) were calculated by a negative exponentialmodel and specific retention rates (ke) computed for each 1m interval. The mean k was 0.0161 +/- 0.0101 (S.E.) and ranged from 0.005 to 0.036 during the study period. This suggests a low retention of particulate matter. The evidence provided by this study shows that there was a relationship between retention and discharge. At low discharges, greater percentages of leaves were retained in a 3-h period while high discharges resulted in low retention percentages within the studied reach. In the Itauna Stream, no significant difference (p < 0.05) was found between the ke values of pool and riffle zones.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: Mucoceles are benign lesions related to the minor salivary glands and their respective ducts frequently affecting oral structures which are generally asymptomatic. Mucoceles are generally characterized by swollen nodular lesions preferentially located on the lower lip and differ from the so-called ranulas, which are lesions located on the floor of the mouth and related to the sublingual or submandibular glands.Methods: The objective of the present study was to analyze data such as age, gender, race and site of the lesion of 173 mucocele cases diagnosed at the Discipline of Stomatology, Sao Jose dos Campos Dental School, UNESP, over a period of 24 years (April 1980 to February 2003).Results: of the 173 cases analyzed, 104 (60.12%) were females and 69 (39.88%) were males. Age ranged from 4 to 70 years (mean +/- SD: 17 +/- 9.53) and most patients were in the second decade of life (n = 86, 49.42%); white (n = 124, 71.68%). The lower lip was the site most frequently affected by the lesions (n = 135, 78.03%), whereas the lowest prevalence was observed for the soft palate, buccal mucosa, and lingual frenum.Conclusion: In this study, mucoceles predominated in white female subjects in the second decade of life, with the lower lip being the most frequently affected site.
Resumo:
Foi avaliado o possível efeito de tratamentos superficiais em pinos de fibra de carbono lisos, quando comparados aos pinos serrilhados, na retenção à resina composta empregada na confecção de núcleos de preenchimento. Foram utilizados cinqüenta pinos de fibra de carbono, divididos em cinco grupos: os quatro primeiros grupos eram constituídos por pinos do tipo liso, cujas superfícies foram tratadas, e o último grupo por dez pinos do tipo serrilhado. Foram desenvolvidas matrizes de resina acrílica com um leito ajustado para conter o pino, com um alargamento na porção coronária para posterior preenchimento com resina composta. Após o tratamento superficial, todos os pinos receberam camadas de primer, foram secos e então ajustados à matriz de resina, colocando-se a resina composta autopolimerizável na porção coronária para um núcleo de preenchimento de 3 mm. As amostras foram submetidas a termociclagem e armazenadas em água destilada por uma semana. Os espécimes foram testados por meio de ensaios mecânicos de tração, à velocidade de 0,5 mm/min, até o deslocamento do conjunto ou a fratura da resina do núcleo. As conclusões foram as seguintes: a) o tratamento superficial nos grupos tratados por meio de jateamento (Grupo A), pontas diamantadas marcadoras de profundidade para facetas laminadas (Grupo C) e alteração da morfologia da extremidade coronária (Grupo D) conferiu aos pinos lisos valores de retenção comparáveis aos dos pinos serrilhados (Grupo E) nos ensaios de tração, porém sem diferença estatisticamente significativa entre estes grupos; b) os pinos tratados por meio de pontas diamantadas de granulação média (Grupo B) obtiveram valores de retenção menores que os demais grupos.
Resumo:
The spreading system is an alternative technique to the Summers osteotome. The crest expansion technique is a less invasive procedure in which the facial wall expands after the medullary bone is compressed against the cortical wall. It improves the density of the maxillary bone, which allows for greater initial stability of implants. A specific screw instrument, the "spreader," achieved a controlled and standardized dilation of the bone horizontally. The use of spreaders to enhance the dental implant site is a highly predictable procedure. (Int J Periodontics Restorative Dent 2011;31:141-147.)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Ferroelectric CaBi4Ti4O15 (CBTi144) thin films were deposited on Pt/Ti/SiO2/Si substrates by the polymeric precursor method. The films present a single phase of layered-structured perovskite with polar axis orientation after annealing at 700 degrees C for 2 h in static air and oxygen atmosphere. The a/b-axis orientation of the ferroelectric film is considered to be associated with the preferred orientation of the Pt bottom electrode. It is noted that the films annealed in static air showed good polarization fatigue characteristics at least up to 10(10) bipolar pulse cycles and excellent retention properties up to 10(4) s. on the other hand, oxygen atmosphere seems to be crucial in the decrease of both, fatigue and retention characteristics of the capacitors. Independently of the applied electric field, the retained switchable polarization approached a nearly steady-state value after a retention time of 10 s. (C) 2006 Elsevier B.V. All rights reserved.