131 resultados para pulsed flame photometric detector
Resumo:
In this study a pulsed Nd:YAG laser was used to join Monel 400 thin foil with 100 mu m thickness. Pulse energy was varied from 1.0 to 2.25J at small increments of 0.25J. The macro and microstructures were analyzed by optical microscopy, tensile shear test and microhardness. Sound laser welds without discontinuities were obtained with 1.5 J pulse energy. Results indicate that using a precise control of the pulse energy, and so a control of the bottom foil dilution rate, it is possible to weld Monel 400 thin foil. The process appeared to be very sensitive to the gap between couples.
Resumo:
In this study a pulsed Nd:YAG laser was used to join Hastelloy C-276 thin foil with 100 microns thickness. Pulse energy was varied from 1.0 to 2.25 J at small increments of 0.25 J with a 4 ms pulse duration. The macro and microstructures of the welds were analyzed by optical and electronic microscopy, tensile shear test and microhardness. Sound laser welds without discontinuities were obtained with 1.5 J pulse energy. Results indicate that using a precise control of the pulse energy, and so a control of the dilution rate, it is possible to weld Hastelloy C-276 thin foil by pulsed Nd: YAG laser. (C) 2012 Published by Elsevier B. V. Selection and/or review under responsibility of Bayerisches Laserzentrum GmbH
Resumo:
Diamond-like carbon (DLC) films were obtained by spinning a tungsten carbide substrate at a high speed using an oxyacetylene flame. The films deposited at a typical experimental condition of substrate temperature of 810 degrees C, rotation of 600 rpm and 3 h deposition time, exhibited an uniform, very smooth, hard and glassy surface covering the entire exposed face of the substrate. These films were identified as DLC by their characteristic broad Raman spectra centered at 1554 cm(-1) and micro-Vicker's hardness > 3400 kg mm(-2). For substrate temperatures < 800 degrees C the film started losing the uniform glassy surface and the hardness deteriorated. For temperatures > 950 degrees C the film was still hard and shiny, but black in color. DLC films were also obtained in a wide range of speeds of rotation (300-750 rpm), as long as the temperature remained close to 850 degrees C. (C) 1999 Elsevier B.V. S.A. All rights reserved.
Resumo:
Background The clinical efficacy of intense pulsed light (IPL) in the treatment of poikiloderma of Civatte (PC) is well documented, but little is known about microscopic changes. Objective To analyze histopathologic findings on the necks of individuals with PC after IPL therapy. Materials and Methods Fourteen patients with PC on the neck underwent three monthly sessions of IPL. Biopsies and clinical photographs were taken before and 60 similar to days after treatment. A dermatopathologist analyzed histopathologic slides stained with hematoxylin and eosin, Masson's trichrome, Verhoeff-van Gieson and Fontana-Masson or processed for CD-34 immunohistochemistry. The slides also underwent digital image analysis. Clinical results were based on the analysis of the pictures by three dermatologists and on patient satisfaction. Results Intense pulsed light treatment resulted in more-homogeneous melanin distribution; a greater number of fibroblasts and nonfragmented elastic fibers; and greater density (p similar to=similar to.01), color intensity (p similar to=similar to.02), number and thickness of the collagen bundles. No significant changes in vessels number or diameters were observed. Clinical results were positive in 92.9% of the cases. Conclusion IPL treatment of PC induced a more-homogeneous distribution of melanin and increased nonfragmented elastic fibers, collagen density, and intensity. These changes were related to clinical improvement.
Resumo:
Various molecular systems are available for epidemiological, genetic, evolutionary, taxonomic and systematic studies of innumerable fungal infections, especially those caused by the opportunistic pathogen C. albicans. A total of 75 independent oral isolates were selected in order to compare Multilocus Enzyme Electrophoresis (MLEE), Electrophoretic Karyotyping (EK) and Microsatellite Markers (Simple Sequence Repeats - SSRs), in their abilities to differentiate and group C. albicans isolates (discriminatory power), and also, to evaluate the concordance and similarity of the groups of strains determined by cluster analysis for each fingerprinting method. Isoenzyme typing was performed using eleven enzyme systems: Adh, Sdh, M1p, Mdh, Idh, Gdh, G6pdh, Asd, Cat, Po, and Lap (data previously published). The EK method consisted of chromosomal DNA separation by pulsed-field gel electrophoresis using a CHEF system. The microsatellite markers were investigated by PCR using three polymorphic loci: EF3, CDC3, and HIS3. Dendrograms were generated by the SAHN method and UPGMA algorithm based on similarity matrices (S(SM)). The discriminatory power of the three methods was over 95%, however a paired analysis among them showed a parity of 19.7-22.4% in the identification of strains. Weak correlation was also observed among the genetic similarity matrices (S(SM)(MLEE) x S(SM)(EK) x S(SM)(SSRs)). Clustering analyses showed a mean of 9 +/- 12.4 isolates per cluster (3.8 +/- 8 isolates/taxon) for MLEE, 6.2 +/- 4.9 isolates per cluster (4 +/- 4.5 isolates/taxon) for SSRs, and 4.1 +/- 2.3 isolates per cluster (2.6 +/- 2.3 isolates/taxon) for EK. A total of 45 (13%), 39(11.2%), 5 (1.4%) and 3 (0.9%) clusters pairs from 347 showed similarity (Si) of 0.1-10%, 10.1-20%, 20.1-30% and 30.1-40%, respectively. Clinical and molecular epidemiological correlation involving the opportunistic pathogen C. albicans may be attributed dependently of each method of genotyping (i.e., MLEE, EK, and SSRs) supplemented with similarity and grouping analysis. Therefore, the use of genotyping systems that give results which offer minimum disparity, or the combination of the results of these systems, can provide greater security and consistency in the determination of strains and their genetic relationships. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Cellulose chemically modified with p-aminobenzoic groups, abbreviated as Cel-PAB, was used for preconcentration of copper, iron, nickel, and zinc from ethanol fuel, normally used in Brazil as engine fuel. The surface characteristics and the surface area of the cellulose were obtained before and after chemical modification using FT-IR, elemental analysis, and surface area analysis (B.E.T.). The retention and recovery of the analyte elements were studied by applying batch and column techniques.
Resumo:
This paper describes the preparation of acid carboxymethylcellulose (CMCH), and the results of a study on the adsorption and preconcentration (using batch and flow-through column methods) of Cd(II), Cu(II), Cr(III), Fe(III), Ni(II) and Zn(II) in ethanol medium. The adsorption capacities for each metallic ion were (in mmol g(-1)) Cd(II) = 0.92; Cu(II) = 1.45; Cr(III) = 1.70; Fe(III) = 1.60; Ni(II) = 1.30; and Zn(II) = 1.10. By means of the flow-through method, a recovery of ca. 100% of the metallic ions adsorbed in a column packed with 2 g of CMCH was found when 5.0 mL of 1.0 mol L-1 hydrochloric acid were used as eluent. An enrichment factor of 20 (100 mt solution containing 50 mu g L-1 of the metallic ions, concentrated to 5.0 mt) was obtained by this preconcentration procedure. The sorption-desorption procedure applied allowed the development of a preconcentration and Flame AAS quantification method of metallic ions in fuel ethanol at trace levels.
Resumo:
5-amino-1,3,4-thiadiazole-2-thiol groups attached on a silica gel surface have been used for adsorption of Cd(II), Co(II), Cu(II), Fe(III), Ni(II), Pb(II) and Zn(II) from aqueous solutions. The adsorption capacities for each metal ion were (in mmol.g(-1)): Cd(II)= 0.35, Co(II)= 0.10, Cu(II)= 0.15, Fe(III)= 0.20, Hg(Il)= 0.46, Ni(II)= 0.16, Pb(II)= 0.13 and Zn(II)= 0.15. The modified silica gel was applied in the preconcentration and quantification of trace level metal ions present in water samples (river, and bog water).
Resumo:
Starches from eight soft wheat samples (two parent lines and six offspring) were isolated; relationships between their structures and properties were examined. Branch chain-length distributions of amylopectins were determined by using high-performance anion exchange chromatography equipped with an amyloglucosidase reactor and a pulsed amperometric detector (HPAEC-ENZ-PAD). Results showed that the average chain length of the eight samples varied at DP 25.6-26.9. Starch samples of lines 02, 60, 63, 95, and 114 consisted of amylopectins with more long chains (DP greater than or equal to 37) and longer average chain length (DP 26.2-26.9) than that of other samples. These starch samples of longer branch chain length displayed higher gelatinization temperatures (55.3-56.5degreesC) than that of other samples (54.4-54.9degreesC) and higher peak viscosity (110-131 RVU) and lower pasting temperature (86.3-87.6degreesC) than others (83-100 RVU and 88.2-88.9degreesC, respectively). The M-w of amylopectins, determined by using high-performance size exclusion chromatography equipped with multiangle laser-light scattering and refractive index detectors (HPSEC-MALLS-RI), were similar for all samples (6.17 x 10(8) to 6.97 x 10(8)). There were no significant differences in amylose and phosphorus contents between samples. These results indicated that physical properties of wheat starch were affected by the branch-chain length of amylopectin.
Resumo:
We present a search for the flavor-changing neutral current decay B-s(0)->phi mu(+)mu(-) using about 0.45 fb(-1) of data collected in p (p) over bar collisions at root s=1.96 TeV with the D0 detector at the Fermilab Tevatron Collider. We find an upper limit on the branching ratio of this decay normalized to B-s(0)-> J/psi phi of B(B-s(0)->phi mu(+)mu(-))/B(B-s(0)-> J/psi phi)< 4.4x10(-3) at the 95% C.L. Using the central value of the world average branching fraction of B-s(0)-> J/psi phi, the limit corresponds to B(B-s(0)->phi mu(+)mu(-))< 4.1x10(-6) at the 95% C.L., the most stringent upper bound to date.
Resumo:
We have searched for a heavy resonance decaying into a Z+jet final state in p (p) over bar collisions at a center of mass energy of 1.96 TeV at the Fermilab Tevatron collider using the D0 detector. No indication for such a resonance was found in a data sample corresponding to an integrated luminosity of 370 pb(-1). We set upper limits on the cross section times branching fraction for heavy resonance production at the 95% C.L. as a function of the resonance mass and width. The limits are interpreted within the framework of a specific model of excited quark production.
Resumo:
The DO experiment enjoyed a very successful data-collection run at the Fermilab Tevatron collider between 1992 and 1996. Since then, the detector has been upgraded to take advantage of improvements to the Tevatron and to enhance its physics capabilities. We describe the new elements of the detector, including the silicon microstrip tracker, central fiber tracker, solenoidal magnet, preshower detectors, forward muon detector, and forward proton detector. The uranium/liquid -argon calorimeters and central muon detector, remaining from Run 1, are discussed briefly. We also present the associated electronics, triggering, and data acquisition systems, along with the design and implementation of software specific to DO. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
lWe report on a search for second generation leptoquarks (LQ(2)) which decay into a muon plus quark in (p) over barp collisions at a center-of-mass energy of root s = 1.96 TeV in the DO detector using an integrated luminosity of about 300 pb(-1). No evidence for a leptoquark signal is observed and an upper bound on the product of the cross section for single leptoquark production times branching fraction into a quark and a muon was determined for second generation scalar leptoquaiks as a function of the leptoquark mass. This result has been combined with a previously published DO search for leptoquark pair production to obtain leptoquark mass limits as a function of the leptoquark-muon-quark coupling, lambda. Assuming lambda = 1, lower limits on the mass of a second generation scalar leptoquark coupling to a u quark and a muon are m(LQ2) > 274 GeV and m(LQ2) > 226 GeV for beta = 1 and beta = 1/2, respectively. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
We present a search for electroweak production of single top quarks in the s-channel (p (p) over bar -> t (b) over bar +X) and t-channel (p (p) over bar -> tq (b) over bar +X) modes. We have analyzed 230 pb(-1) of data collected with the D0 detector at the Fermilab Tevatron Collider at a center-of-mass energy of root s=1.96 TeV. No evidence for a single top quark signal is found. We set 95% confidence level upper limits on the production cross sections, based on binned likelihoods formed from a neural network output. The observed (expected) limits are 6.4 pb (4.5 pb) in the s-channel and 5.0 pb (5.8 pb) in the t-channel.
Resumo:
We present measurements of the Lambda(b)(0) lifetime in the exclusive decay channel Lambda(b)(0)-> J/psi Lambda(0), with J/psi ->mu(+)mu(-) and Lambda(0)-> p pi(-), the B-0 lifetime in the decay B-0-> J/psi K-S(0) with J/psi ->mu(+)mu(-) and K-S(0)->pi(+)pi(-), and the ratio of these lifetimes. The analysis is based on approximately 250 pb(-1) of data recorded with the D0 detector in p (p) over bar collisions at root s = 1.96 TeV. The Lambda(b)(0) lifetime is determined to be tau(Lambda(b)(0))=1.22(-0.18)(+0.22)(stat)+/- 0.04(syst) ps, the B-0 lifetime tau(B-0)=1.40(-) (+0.11)(0.10)(stat)+/- 0.03(syst) ps, and the ratio tau(Lambda(b)(0))/tau(B-0)=0.87(-) (+0.17)(0.14)(stat)+/- 0.03(syst). In contrast with previous measurements using semileptonic decays, this is the first determination of the Lambda(b)(0) lifetime based on a fully reconstructed decay channel.