100 resultados para precision experiment


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the results of an intracavity Stark spectroscopy experiment on the fundamental state of (CD3OH)-C-13. We use an optically pumped hybrid waveguide FIR laser, CH2F2 as active molecule, and (CD3OH)-C-13 as absorbent molecule. No Brewster window is needed to separate the lasing gas from the absorbing deuterated methanol. An absorption line is assigned as E(l) symmetry (n, K, J): (1,4,18) --> (1,5,18) and its frequency is measured as 63.08631 cm(-1) with a precision of a few parts in 10(7); two more absorptions are reported and a tentative assignment for one of them.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider certain quadrature rules of highest algebraic degree of precision that involve strong Stieltjes distributions (i.e., strong distributions on the positive real axis). The behavior of the parameters of these quadrature rules, when the distributions are strong c-inversive Stieltjes distributions, is given. A quadrature rule whose parameters have explicit expressions for their determination is presented. An application of this quadrature rule for the evaluation of a certain type of integrals is also given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Throughout late 1998 and early 1999, the International GLONASS Experiment (IGEX) has delivered the first comprehensive inter-continental dual frequency GLONASS data set. This experiment represents the first opportunity to assess how a second global satellite positioning system could complement existing CPS geodetic infrastructure. Based on analysis of a three station network of IGEX stations from Southern Hemisphere IGEX stations, this paper discusses the internal and external precision of long baseline GPS, GLONASS and combined GPS/GLONASS solutions, and the possible contribution of GLONASS to future regional-scale geodetic work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was undertaken in a closed system with Nile tilapia (Oreochromis niloticus) to examine the effects of total replacement of fish meal (FM) by soybean meal. Nile tilapia fingerlings with an average weight of 5.34+/-0.08 g were hand-fed one of the five isoenergetic (approximate to13.5 MJ digestible energy kg(-1)) and isoproteic (approximate to31% of digestible protein) experimental diets to satiation, six times a day during 85 days in eight replicate fibreglass tanks (six fish per tank). The control diet containing FM was substituted by soybean meal, with and without essential amino acids (lysine, methionine and threonine) or dicalcium phosphate supplementation. The supplemental amino acids were added at levels to simulate the reference amino acid profile of Nile tilapia carcass protein, based on the ideal protein concept. The results showed that soybean meal diet supplemented only with dicalcium phosphate was inferior to the control diet with FM and soybean meal diets supplemented with dicalcium phosphate and essential amino acids. Multiple essential amino acids and dicalcium phosphate incorporation in soybean meal diets was associated with performance, whole-body composition and carcass yield equal to that of the fish fed with the control diet containing FM. These data suggest that a diet with all plant protein source, supplemented with essential amino acids, based on tissue amino acid profile, can totally replace FM in a diet for Nile tilapia, without adverse effects on the growth performance, carcass yield and composition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to test a device developed to improve the functionality, accuracy and precision of the original technique for sweating rate measurements proposed by Schleger and Turner [Schleger AV, Turner HG (1965) Aust J Agric Res 16:92-106]. A device was built for this purpose and tested against the original Schleger and Turner technique. Testing was performed by measuring sweating rates in an experiment involving six Mertolenga heifers subjected to four different thermal levels in a climatic chamber. The device exhibited no functional problems and the results obtained with its use were more consistent than with the Schleger and Turner technique. There was no difference in the reproducibility of the two techniques (same accuracy), but measurements performed with the new device had lower repeatability, corresponding to lower variability and, consequently, to higher precision. When utilizing this device, there is no need for physical contact between the operator and the animal to maintain the filter paper discs in position. This has important advantages: the animals stay quieter, and several animals can be evaluated simultaneously. This is a major advantage because it allows more measurements to be taken in a given period of time, increasing the precision of the observations and diminishing the error associated with temporal hiatus (e.g., the solar angle during field studies). The new device has higher functional versatility when taking measurements in large-scale studies (many animals) under field conditions. The results obtained in this study suggest that the technique using the device presented here could represent an advantageous alternative to the original technique described by Schleger and Turner.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diarylpropenamine derivatives are a class of compounds which have been evaluated as potential drug candidates. Here a specific and reproducible HPLC method for the determination of cis- and trans-isomers of the unsubstituted derivative, 3-(4'-bromo-[1,1'-biphenyl]-4-yl)-3-(4-X-phenyl-N,N-dimethyl-2-propen-1-amine (I, where X=H) in feces is described. The analyte I and internal standard, nitro derivative (II, where X=NO2), were isolated from the basified biological matrix using a liquid-liquid extraction with ethyl acetate followed by a solid-phase procedure performed on a silica cartridge. The organic phase was evaporated to dryness, the residue was reconstituted in mobile phase and injected into the HPLC system. The analytes were eluted with ethyl acetate-hexane-triethylamine (59:40:1) in HPLC column (silica) and detected by UV spectrophotometry at 272 nm. Linearity, precision and accuracy data for feces standards after extraction were acceptable. The method has been applied to analyses of feces samples from rats dosed with I, in which it could be anticipated that fecal excretion is quantitatively the major route for I elimination. Copyright (C) 1999 Elsevier Science B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Point positioning from GPS data can provide precision varying from 100 meters to a few millimeters at the level of 95% probability. To reach the best level of accuracy, users need proper equipment and software, as well as access capability to GPS products available at the International GPS Geodynamics Service. In this paper, the theory related to point positioning using GPS is presented as well as the results of an experiment conducted using data from the Brazilian Active Control System. The results show repeatability better than 5mm and 10mm for the N and E baseline components respectively, and 6mm + 4ppb (parts per billion) for the vertical. Comparison with SIRGAS campaign showed results at the same level of uncertainty as that of the stations used to tie the SIRGAS frame to ITRF94. Therefore, precise point positioning is a powerful tool to be used in applications requiring high level of precision, such as Geodynamics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A measurement technique of charm baryons lifetimes from hadro-production data was presented. The measurement verified the lifetime analysis procedure in a sample with higher statistical precision. Other effects studied include mass reflections; effects of the presence of a second charm particle; and mismeasurement of charm decays. Monte carlo simulations were used for the detailed study of systematic effects using the charm data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a new method is proposed of separated estimation for the ARMA spectral model based on the modified Yule-Walker equations and on the least squares method. The proposal of the new method consists of performing an AR filtering in the random process generated obtaining a new random estimate, which will reestimate the ARMA model parameters, given a better spectrum estimate. Some numerical examples will be presented in order to ilustrate the performance of the method proposed, which is evaluated by the relative error and the average variation coefficient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Methods were developed for the analysis of acetonitrile and its metabolite cyanide in the blood of rats exposed to acetonitrile. Acetonitrile was analyzed by the headspace technique coupled to gas chromatography with detection by flame ionization, and cyanide was analyzed by high-performance liquid chromatography with fluorescence detection (λ ex = 418 nm and λ em = 460 nm) after derivatization of the ion with naphthalene 2,3-dicarboxyaldehyde and taurine. The quantitation limits of the methods for the analysis of acetonitrile and cyanide were 4.875 μg/mL and 0.025 μg/mL, respectively. The coefficients of variation of 10% or less obtained for intra- and interassay precision indicate the precision of these analytical methods and the systematic errors, all less than 5%, indicate that the methods are quite accurate. The methods were applied to an experimental study after the animals received acetonitrile at the doses of 2 mmol/kg or 5 mmol/kg.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The in-medium influence on π0 photoproduction from spin zero nuclei is carefully studied in the GeV range using a straightforward Monte Carlo analysis. The calculation takes into account the relativistic nuclear recoil for coherent mechanisms (electromagnetic and nuclear amplitudes) plus a time dependent multi-collisional intranuclear cascade approach (MCMC) to describe the transport properties of mesons produced in the surroundings of the nucleon. A detailed analysis of the meson energy spectra for the photoproduction on 12C at 5.5 GeV indicates that both the Coulomb and nuclear coherent events are associated with a small energy transfer to the nucleus (≲ 5 MeV), while the contribution of the nuclear incoherent mechanism is vanishing small within this kinematical range. The angular distributions are dominated by the Primakoff peak at extreme forward angles, with the nuclear incoherent process being the most important contribution above θπ0 ≲ 20. Such consistent Monte Carlo approach provides a suitable method to clean up nuclear backgrounds in some recent high precision experiments, such as the PrimEx experiment at the Jefferson Laboratory Facility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The purpose of this study was to compare the accuracy of two working cast fabrication techniques using strain-gauge analysis. Methods: Two working cast fabrication methods were evaluated. Based on a master model, 20 working casts were fabricated by means of an indirect impression technique using polyether after splinting the square transfer copings with acrylic resin. Specimens were assigned to 2 groups (n=10): Group A (GA): type IV dental stone was poured around the abutment analogs in the conventional way; Group B (GB), the dental stone was poured in two stages. Spacers were used over the abutment analogs (rubber tubes) and type IV dental stone was poured around the abutment analogs in the conventional way. After the stone had hardened completely, the spacers were removed and more stone was inserted in the spaces created. Six strain-gauges (Excel Ltd.), positioned in a cast bar, which was dimensionally accurate (perfect fit) to the master model, recorded the microstrains generated by each specimen. Data were analyzed statistically by the variance analysis (ANOVA) and Tukey's test (α= 5%). Results: The microstrain values (με) were (mean±SD): GA: 263.7±109.07με, and GB: 193.73±78.83με. Conclusion: There was no statistical difference between the two methods studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Integer carrier phase ambiguity resolution is the key to rapid and high-precision global navigation satellite system (GNSS) positioning and navigation. As important as the integer ambiguity estimation, it is the validation of the solution, because, even when one uses an optimal, or close to optimal, integer ambiguity estimator, unacceptable integer solution can still be obtained. This can happen, for example, when the data are degraded by multipath effects, which affect the real-valued float ambiguity solution, conducting to an incorrect integer (fixed) ambiguity solution. Thus, it is important to use a statistic test that has a correct theoretical and probabilistic base, which has became possible by using the Ratio Test Integer Aperture (RTIA) estimator. The properties and underlying concept of this statistic test are shortly described. An experiment was performed using data with and without multipath. Reflector objects were placed surrounding the receiver antenna aiming to cause multipath. A method based on multiresolution analysis by wavelet transform is used to reduce the multipath of the GPS double difference (DDs) observations. So, the objective of this paper is to compare the ambiguity resolution and validation using data from these two situations: data with multipath and with multipath reduced by wavelets. Additionally, the accuracy of the estimated coordinates is also assessed by comparing with the ground truth coordinates, which were estimated using data without multipath effects. The success and fail probabilities of the RTIA were, in general, coherent and showed the efficiency and the reliability of this statistic test. After multipath mitigation, ambiguity resolution becomes more reliable and the coordinates more precise. © Springer-Verlag Berlin Heidelberg 2007.