58 resultados para partial pressure


Relevância:

60.00% 60.00%

Publicador:

Resumo:

We have measured hemoglobin oxygen uptake vs. The partial pressure of oxygen, with independently controlled activities of chloride and water. This control is effected by combining different concentrations of NaCl and sucrose in the bathing solution to achieve: (i) water activities were varied and CI- activity was fixed, (ii) both water and CI- activities were varied with a traditional NaCI titration, or (iii) CI- activities were varied and water activity was fixed by adding compensating sucrose. Within this analysis, the CI--regulated loading of four oxygens can be described by the reaction Hb.CI- + 4 O-2 + 65 H2O reversible arrow Hb.4O(2).65H(2)O + CI-. The dissociation of a neatly integral chloride, rather than the nonintegral 1.6 chlorides inferred earlier from simple salt titration, demonstrates the need to recognize the potentially large contribution from changes in water activity when titrating weakly binding solutes. The single-chloride result might simplify structural considerations of the action of CI- in hemoglobin regulation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To determine the effects of storage of arterial and venous blood samples in ice water on blood gas and acid-base measurements.Design: Prospective, in vitro, laboratory study.Setting: School of veterinary medicine.Subjects: Six healthy dogs.Measurements and main results: Baseline measurements of partial pressure of oxygen (PO2), partial pressure of carbon dioxide (PCO2), pH, hemoglobin concentration (tHb), oxyhemoglobin saturation, and oxygen content (ContO(2)) were made. Bicarbonate (HCO3) and standard base excess (SBE) were calculated. Arterial and venous blood samples were separated into 1 and 3 mL samples, anaerobically transferred into 3 mL plastic syringes, and stored in ice water for 6 hours. Measurements were repeated at 15, 30 minutes, and 1, 2, 4, and 6 hours after baseline measurements. Arterial (a) PO2 increased significantly from baseline after 30 minutes of storage in the 1 mL samples and after 2 hours in the 3 mL samples. Venous (v) PO2 was significantly increased from baseline after 4 hours in the 1 mL samples and after 6 hours in the 3 mL samples. The pHa significantly decreased after 2 hours of storage in the 1 mL samples and after 4 hours in the 3 mL samples. In both the 1 and 3 mL samples, pHv decreased significantly only after 6 hours. Neither the arterial nor the venous PCO2 values changed significantly in the 1 mL samples and increased only after 6 hours in the 3 mL samples. No significant changes in tHb, ContO(2), SBE, or HCO3 were detected.Conclusions: the PO2 of arterial and venous blood increased significantly when samples were stored in plastic syringes in ice water. These increases are attributable to the diffusion of oxygen from and through the plastic of the syringe into the blood, which occurred at a rate that exceeded metabolic consumption of oxygen by the nucleated cells.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

SnO2 deposited by sol-gel is a polycrystalline film with small grain size. Oxygen present at a less grain boundary traps electrons and then the depletion layer around the potential barrier of the grain boundary becomes wider, comparable to the grain size. We have modeled the conductivity taking into account the trapped charge at the depletion layer of the grain boundary and other scattering mechanisms such as ionized impurity and polar optical. Experimental data of photoconductivity of SnO2 sol-gel films are simulated considering the dominant scattering at grain boundary and crystallite bulk. The fraction of trapped charge at the grain boundary depends on temperature and wavelength of irradiating light, being as high as 50% for illumination in the range 500-600 nm for SnO2-2%Nb as grown sample annealed in air to 550°C. This fraction can be quite reduced depending on exposure to light and annealing under different oxygen partial pressure conditions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Evaporative cooling operates using water and air as working fluids. It consists in water evaporation, through the passage of an airflow, thus decreasing the air temperature. This system has a great potential to provide thermal comfort in places where air humidity is low, being, however, less efficient where air humidity is high. A way to solve this problem is to use dehumidifiers to pre-conditioning the process air. This paper presents a system that can be used in humid climates coupling desiccant dehumidification equipment to evaporative coolers. The paper shows, initially, the main characteristics of the evaporative cooling and of the adsorption dehumidification systems. Later on the coupled systems, in which occurs a dehumidification by adsorption in a counter flow rotary heat exchanger following the evaporate cooling of the air in evaporative coolers, are analyzed. The thermodynamic equations of state are also presented. Following, this paper analyzes some operation parameters such as: reactivation temperature, R/P relationship (reactivation air flow/ process air flow) and the thermodynamic conditions of the entering air flow. The paper shows the conditions for the best operation point, with regard to thermal comfort conditions and to the energy used in the process. In addition this paper presents an application of the system in different climate characteristics of several tropical and equatorial cities. Copyright © 2005 by ABCM.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The short-range diffusion phenomenon (Snoek Effect) was investigated by mechanical spectroscopy measurements between 300 K and 650 K, in a polycrystalline niobium sample, containing oxygen and nitrogen, using a torsion pendulum. Experimental spectra of anelastic relaxation were obtained under three conditions: as-received sample; annealed sample and subsequently annealed in an oxygen atmosphere for three hours at 1170 K in partial pressure of 5°10 -5mbar. The experimental spectra obtained were decomposed in elementary Debye peaks and the anelastic relaxation processes were identified. With anelastic relaxation parameters and the lattice parameters, the interstitial diffusion coefficients of the oxygen and nitrogen in niobium were calculated for each kind of preferential occupation (octahedral and tetrahedral). The results were compared with the literature data, and confirmed that the best adjustment is for the preferential occupation octahedral model for low concentrations of interstitial solutes, but at higher concentration of oxygen were observed deviations of experimental data for the interstitial diffusion coefficients of oxygen in niobium when compared with the literature data, this could be related to the possible occurrence of a double occupation of interstitial sites in the niobium lattice by oxygen interstitials. © (2010) Trans Tech Publications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Geociências e Meio Ambiente - IGCE

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate gasometric differences of severe trauma patients requiring intubation in prehospital care. METHODS: Patients requiring airway management were submitted to collection of arterial blood samples at the beginning of pre-hospital care and at arrival at the Emergency Room. We analyzed: Glasgow Coma Scale, respiratory rate, arterial pH, arterial partial pressure of CO2 (PaCO2), arterial partial pressure of O2 (PaO2), base excess (BE), hemoglobin O2 saturation (SpO2) and the relation of PaO2 and inspired O2 (PaO2/FiO2). RESULTS: There was statistical significance of the mean differences between the data collected at the site of the accident and at the entrance of the ER as for respiratory rate (p = 0.0181), Glasgow Coma Scale (p = 0.0084), PaO2 (p <0.0001) and SpO2 (p = 0.0018). CONCLUSION: tracheal intubation changes the parameters PaO2 and SpO2. There was no difference in metabolic parameters (pH, bicarbonate and base excess). In the analysis of blood gas parameters between survivors and non-survivors there was statistical difference between PaO2, hemoglobin oxygen saturation and base excess.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A técnica de analgesia multimodal, por meio da infusão contínua de fármacos, pode ser empregada para diminuir a incidência de sensibilização central durante a anestesia. Avaliaram-se as características cardiorrespiratórias, durante o procedimento de artroscopia de joelho, em cães anestesiados com isofluorano e monitorados por meio do índice biespectral, submetidos à infusão contínua de morfina ou fentanil, associada à lidocaína e cetamina. Utilizaram-se 16 cães adultos, machos ou fêmeas, os quais foram distribuídos aleatoriamente em dois grupos, denominados MLK - que recebeu morfina (3,3μg/kg/min), lidocaína (50μg/kg/min) e cetamina (10μg/kg/min) ou FLK - em que foi substituída a morfina pelo fentanil (0,03μg/kg/min). Os cães foram pré-tratados com levomepromazina (0,5mg/kg IV), induzidos à anestesia com propofol (5mg/kg) e mantidos com isofluorano, ajustando-se a concentração para obterem-se valores de índice biespectral entre 55 e 65. As mensurações da frequência cardíaca (FC), dos parâmetros eletrocardiográficos (ECG), das pressões arteriais sistólica (PAS), diastólica (PAD) e média (PAM), da tensão de dióxido de carbono expirado (EtCO2), da saturação de oxi-hemoglobina (SpO2), da frequência respiratória (FR) e da temperatura esofágica (T) iniciaram-se 30 minutos após a indução (M0) e continuaram após o início da infusão das soluções, em intervalos de 15 minutos (M15 a M75). Diferenças entre os grupos foram registradas para duração do complexo QRS (M60), para FC e T, entre M30 e M75, com MLK apresentando médias maiores que FLK, que registrou médias maiores que MLK para a SpO2 (M60), para os intervalos QT (M30 e M75) e RR (M0, M60 e M75). Concluiu-se que o emprego de morfina ou fentanil, associados à lidocaína e cetamina, promove efeitos semelhantes e não compromete as características avaliadas.