45 resultados para oxygen partial pressure


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJETIVO: Comparar a formação de shunt venoso-arterial em pulmões de cães submetidos a anestesia geral inalatória utilizando-se sistemas de anestesia com e sem reinalação, com fração inspirada de oxigênio de 0,4 e 0,9, respectivamente. MÉTODOS: Empregaram-se 20 cães induzidos com tiopental sódico (30mg/kg) e mantidos com sevoflurano (3%) e alocados em dois grupos (n=10); os animais de GI foram ventilados com modalidade controlada em sistema semifechado, sem reinalação, F I O2 = 0,9, e os de GII, com modalidade controlada, sistema semifechado, com reinalação e F I O2 = 0,4. Os atributos analisados durante o experimento foram: freqüência cardíaca, pressão arterial média, shunt pulmonar venoso-arterial, hematócrito, hemoglobina, pressão parcial de oxigênio arterial, pressão parcial de oxigênio no sangue venoso misto, saturação de oxigênio no sangue venoso misto, pressão parcial de dióxido de carbono arterial e pressão de vapor de água nos alvéolos (P VA). RESULTADOS: A P VA foi significativamente maior em GII. A análise estatística dos valores encontrados de shunt mostrou que GI e GII apresentaram diferenças significativas, sendo que os resultados de GI são maiores que os de GII em todos os momentos avaliados. Já a análise de momentos dentro de um mesmo grupo não demonstrou diferenças. CONCLUSÃO: O sistema de anestesia sem reinalação com F I O2 = 0,9 desenvolveu maior grau de shunt pulmonar venoso-arterial que o sistema de anestesia com reinalação e F I O2 = 0,4. A umidificação dos gases em GII contribuiu para diminuir o shunt.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The caprine oxyhemoglobin dissociation curve has not been previously defined. Blood from 10 healthy goats was equilibrated in a tonometer with calibrated gas mixtures of oxygen at concentrations of 95%, 21%, 13%, 12%, 10%, 9%, 8%, 5%, 4% and 2.5%, 5% carbon dioxide, balance nitrogen. The pH, partial pressure of oxygen (PO2), partial pressure of carbon dioxide (PCO2), total hemoglobin, oxyhemoglobin saturation, carboxyhemoglobin, methemoglobin, and oxygen content were measured. The PO2/oxyhemoglobin and the PO2/oxygen content relationships were graphed with curve-fitting software and a formula for calculating oxyhemoglobin from PO2 was generated. The maximum oxygen content per gram of hemoglobin was 1.29 ml of oxygen per gram of hemoglobin. The PO2 at which hemoglobin was 50% saturated (P-50) from the PO2/oxyhemoglobin relationship was 28.6 +/- 1.5 mmHg and that from the PO2/oxygen content relationships was 29.1 +/- 1.6 mmHg. The Hill coefficient for the PO2/oxyhemoglobin data was 3.0 +/- 0.4. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The objective of this study was to determine intraocular pressure (IOP) and cardiac changes in normocapnic dogs maintained under controlled ventilation and anesthetized using sevoflurane or desflurane. Sixteen healthy adult mixed-breed dogs, seven males and nine females, weighing 10-15 kg were used. The dogs were randomly assigned to one of two groups composed of eight animals anesthetized with sevoflurane (SEVO) or desflurane (DESF). In both groups, anesthesia was induced with propofol (10 mg/kg), and neuromuscular blockade was achieved with rocuronium (0.6 mg/kg/h IV). No premedication was given. Ventilation was adjusted to maintain end-tidal carbon dioxide partial pressure at 35 mmHg. Anesthesia was maintained with 1.5 minimum alveolar concentration (MAC) of sevoflurane or desflurane. In both groups IOP was measured by applanation tonometry (Tono-Pen) before induction of anesthesia. IOP, mean arterial pressure (MAP), heart rate (HR), cardiac index (CI) and central venous pressure (CVP) were also measured 45 min after the beginning of inhalant anesthesia and then every 20 min for 60 min. A one-way repeated measures ANOVA was used to compare data within the same group and Student's t-test was used to assess differences between groups. P < 0.05 was considered statistically significant. Measurements showed normal IOP values in both groups, even though IOP increased significantly from baseline during the use of desflurane. IOP did not differ between groups. CI in the desflurane group was significantly greater than in the sevoflurane group. Sevoflurane and desflurane have no clinically significant effects on IOP, MAP, HR, CI or VCP in the dog.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: To determine the effects of storage of arterial and venous blood samples in ice water on blood gas and acid-base measurements.Design: Prospective, in vitro, laboratory study.Setting: School of veterinary medicine.Subjects: Six healthy dogs.Measurements and main results: Baseline measurements of partial pressure of oxygen (PO2), partial pressure of carbon dioxide (PCO2), pH, hemoglobin concentration (tHb), oxyhemoglobin saturation, and oxygen content (ContO(2)) were made. Bicarbonate (HCO3) and standard base excess (SBE) were calculated. Arterial and venous blood samples were separated into 1 and 3 mL samples, anaerobically transferred into 3 mL plastic syringes, and stored in ice water for 6 hours. Measurements were repeated at 15, 30 minutes, and 1, 2, 4, and 6 hours after baseline measurements. Arterial (a) PO2 increased significantly from baseline after 30 minutes of storage in the 1 mL samples and after 2 hours in the 3 mL samples. Venous (v) PO2 was significantly increased from baseline after 4 hours in the 1 mL samples and after 6 hours in the 3 mL samples. The pHa significantly decreased after 2 hours of storage in the 1 mL samples and after 4 hours in the 3 mL samples. In both the 1 and 3 mL samples, pHv decreased significantly only after 6 hours. Neither the arterial nor the venous PCO2 values changed significantly in the 1 mL samples and increased only after 6 hours in the 3 mL samples. No significant changes in tHb, ContO(2), SBE, or HCO3 were detected.Conclusions: the PO2 of arterial and venous blood increased significantly when samples were stored in plastic syringes in ice water. These increases are attributable to the diffusion of oxygen from and through the plastic of the syringe into the blood, which occurred at a rate that exceeded metabolic consumption of oxygen by the nucleated cells.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this study was to assess positive end-expiratory pressure (PEEP)-induced lung overdistension and alveolar recruitment in six patients with acute lung injury (ALI) using a computed tomographic (CT) scan method. Lung overdistension was first determined in six healthy volunteers in whom CT sections were obtained at FRC and at TLC with a positive airway pressure of 30 cm H2O. In patients, lung volumes were quantified by the analysis of the frequency distribution of CT numbers on the entire lung at zero end-expiratory pressure (ZEEP) and PEEP. In healthy volunteers at FRC, the distribution of the density histograms was monophasic with a peak at -791 ± 12 Hounsfield units (HU). The lowest CT number observed was -912 HU. At TLC, lung volume increased by 79 ± 35% and the peak CT number decreased to -886 ± 26 HU. More than 70% of the increase in lung volume was located below -900 HU, suggesting that this value can be considered as the threshold separating normal aeration from overdistension. In patients with ALI, at ZEEP the distribution of density histograms was either monophasic (n = 3) or biphasic (n = 3). The mean CT number was -319 ± 34 HU. At PEEP 13 ± 3 cm H2O, lung volume increased by 47 ± 19% whereas mean CT number decreased to -538 ± 171 HU. PEEP induced a mean alveolar recruitment of 320 ± 160 ml and a mean lung overdistension of 238 ± 320 ml. In conclusion, overdistended lung parenchyma of healthy volunteers is characterized by a CT number below -900 HU. This threshold can be used in patients with ALI for differentiating PEEP-induced alveolar recruitment from lung overdistension.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate gasometric differences of severe trauma patients requiring intubation in prehospital care. METHODS: Patients requiring airway management were submitted to collection of arterial blood samples at the beginning of pre-hospital care and at arrival at the Emergency Room. We analyzed: Glasgow Coma Scale, respiratory rate, arterial pH, arterial partial pressure of CO2 (PaCO2), arterial partial pressure of O2 (PaO2), base excess (BE), hemoglobin O2 saturation (SpO2) and the relation of PaO2 and inspired O2 (PaO2/FiO2). RESULTS: There was statistical significance of the mean differences between the data collected at the site of the accident and at the entrance of the ER as for respiratory rate (p = 0.0181), Glasgow Coma Scale (p = 0.0084), PaO2 (p <0.0001) and SpO2 (p = 0.0018). CONCLUSION: tracheal intubation changes the parameters PaO2 and SpO2. There was no difference in metabolic parameters (pH, bicarbonate and base excess). In the analysis of blood gas parameters between survivors and non-survivors there was statistical difference between PaO2, hemoglobin oxygen saturation and base excess.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A técnica de analgesia multimodal, por meio da infusão contínua de fármacos, pode ser empregada para diminuir a incidência de sensibilização central durante a anestesia. Avaliaram-se as características cardiorrespiratórias, durante o procedimento de artroscopia de joelho, em cães anestesiados com isofluorano e monitorados por meio do índice biespectral, submetidos à infusão contínua de morfina ou fentanil, associada à lidocaína e cetamina. Utilizaram-se 16 cães adultos, machos ou fêmeas, os quais foram distribuídos aleatoriamente em dois grupos, denominados MLK - que recebeu morfina (3,3μg/kg/min), lidocaína (50μg/kg/min) e cetamina (10μg/kg/min) ou FLK - em que foi substituída a morfina pelo fentanil (0,03μg/kg/min). Os cães foram pré-tratados com levomepromazina (0,5mg/kg IV), induzidos à anestesia com propofol (5mg/kg) e mantidos com isofluorano, ajustando-se a concentração para obterem-se valores de índice biespectral entre 55 e 65. As mensurações da frequência cardíaca (FC), dos parâmetros eletrocardiográficos (ECG), das pressões arteriais sistólica (PAS), diastólica (PAD) e média (PAM), da tensão de dióxido de carbono expirado (EtCO2), da saturação de oxi-hemoglobina (SpO2), da frequência respiratória (FR) e da temperatura esofágica (T) iniciaram-se 30 minutos após a indução (M0) e continuaram após o início da infusão das soluções, em intervalos de 15 minutos (M15 a M75). Diferenças entre os grupos foram registradas para duração do complexo QRS (M60), para FC e T, entre M30 e M75, com MLK apresentando médias maiores que FLK, que registrou médias maiores que MLK para a SpO2 (M60), para os intervalos QT (M30 e M75) e RR (M0, M60 e M75). Concluiu-se que o emprego de morfina ou fentanil, associados à lidocaína e cetamina, promove efeitos semelhantes e não compromete as características avaliadas.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Zootecnia - FCAV

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The interaction among heavy interstitial atoms present in metals with bcc structure is studied using anelastic spectroscopy. This technique makes it possible to obtain information on interstitial concentration, precipitation, solubility limit, and diffusion. The diffusion coefficients of nitrogen in niobium were obtained using the relaxation parameters obtained from anelastic spectroscopy measurements for different oscillation frequencies of the system. The results showed the interstitial diffusion of nitrogen present in solid solution in niobium when submitted to different charges of nitrogen at a temperature of 1373 K and a partial pressure in the order of 10-4 Torr. The exponential variation of the pressure experimentally in function of the time was thus obtained.