116 resultados para maximum steady state lactate


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The perceived exertion has been a target of several investigations, many times with association with objective physiological indicators in exercise. Recently, the identification of the perceived exertion threshold (PET) was proposed in the water running, which presented no difference in relation to the critical velocity. Theoretically, both parameters would be indicators of the maximum steady state of variables such as V̇O2 and blood lactate. The objective of this work was to verify the coincidence between PET, critical power (PCrit) and an indicator of maximum V̇O2 steady state (PCrit') in cycle ergometer. Eight male participants were submitted to progressive effort test in order to determine V̇O2peak (46.7 ± 8.5 ml/kg/min) and to four rectangular tests until exhaustion for the estimation of the critical power model parameters, PET and PCrit'. The hyperbolic relation between mechanical power and time spent for the V̇O2peak to be reached in each test was used for the PCrit' estimation, considered as the asymptote in the power axis, and the portion of the anaerobic work capacity (CTAnaer) depleted up to the establishment of the V̇O2peak (CTAnaer'). In order to identify PET, the straight lines angular coefficients of the perceived exertion in time (ordinate) and the powers used (abscissa) were adjusted to a linear function that provided a point in the power axis in which the perceived exertion would be kept indefinitely stable. The parameters PCrit and CTAnaer were estimated by means of the power-time non-linear equation. In order to compare the estimations of PET, PCrit and PCrit', the analysis of variance ANOVA for repeated measurements was employed, and the associations were established through the Pearson correlation. CTAnaer and CTAnaer' were compared through the t test. PET (180 W ± 61 W), PCrit (174 W ± 43 W) and PCrit' (176 W ± 48 W) were not significantly different and the correlations were of 0.92-0.98. CTAnaer' (14,080 ± 5,219 J) was lower than CTAnaer (22,093 ± 9,042 J). One concludes that the PET predicts the intensity of PCrit and PCrit' with accuracy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, the calculation of the steady-state operation of a radial/meshed electrical distribution system (EDS) through solving a system of linear equations (non-iterative load flow) is presented. The constant power type demand of the EDS is modeled through linear approximations in terms of real and imaginary parts of the voltage taking into account the typical operating conditions of the EDS's. To illustrate the use of the proposed set of linear equations, a linear model for the optimal power flow with distributed generator is presented. Results using some test and real systems show the excellent performance of the proposed methodology when is compared with conventional methods. © 2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO:Relatar o caso de um lactente com citomegalovírus congênito e disacusia neurossensorial progressiva, analisado por três métodos de avaliação auditiva.DESCRIÇÃO DO CASO:Na primeira avaliação auditiva, aos quatro meses de idade, o lactente apresentou ausência de Emissões Otoacústicas (EOA) e Potencial Evocado Auditivo de Tronco Encefálico (PEATE) dentro dos padrões de normalidade para a faixa etária, com limiar eletrofisiológico em 30dBnHL, bilateralmente. Com seis meses, apresentou ausência de PEATE bilateral em 100dBnHL. A avaliação comportamental da audição mostrou-se prejudicada devido ao atraso no desenvolvimento neuropsicomotor. Aos oito meses, foi submetido ao exame de Resposta Auditiva de Estado Estável (RAEE) e os limiares encontrados foram 50, 70, ausente em 110 e em 100dB, respectivamente para 500, 1.000, 2.000 e 4.000Hz, à direita, e 70, 90, 90 e ausente em 100dB, respectivamente para 500, 1.000, 2.000 e 4.000Hz, à esquerda.COMENTÁRIOS:Na primeira avaliação, o lactente apresentou alteração auditiva no exame de EOA e PEATE normal, que passou a ser alterado aos seis meses de idade. A intensidade da perda auditiva só pôde ser identificada pelo exame de RAEE, permitindo estabelecer a melhor conduta na adaptação de aparelho de amplificação sonora individual. Ressalta-se a importância do acompanhamento audiológico para crianças com CMV congênito.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The steady-state average run length is used to measure the performance of the recently proposed synthetic double sampling (X) over bar chart (synthetic DS chart). The overall performance of the DS X chart in signaling process mean shifts of different magnitudes does not improve when it is integrated with the conforming run length chart, except when the integrated charts are designed to offer very high protection against false alarms, and the use of large samples is prohibitive. The synthetic chart signals when a second point falls beyond the control limits, no matter whether one of them falls above the centerline and the other falls below it; with the side-sensitive feature, the synthetic chart does not signal when they fall on opposite sides of the centerline. We also investigated the steady-state average run length of the side-sensitive synthetic DS X chart. With the side-sensitive feature, the overall performance of the synthetic DS X chart improves, but not enough to outperform the non-synthetic DS X chart. Copyright (C) 2014 John Wiley &Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To characterize the thresholds of the auditory steady-state response that relates to term newborns and infants. Design: The study was cross-sectional using auditory steadystate response assessment, and the real-ear-to-dial difference was measured in the external auditory canal. Study Sample: The study group included 60 newborns and infants between the age of 0 and 6 months. Results: A statistically significant difference was found in the carrier frequency variable for auditory steady-state response thresholds but not in comparison to ages. Furthermore, there is an association between auditory steady-state response thresholds and the real-ear-to-dial difference. Conclusion: The same threshold can be used as a normality reference for this age range, with distinct values for the different carrier frequencies. The influence of external auditory canal amplification should be taken into account.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This research aims to present a new method to get real attenuation of hearing protection devices, with good reproducibility and a small standard deviation, without relying on skills and cooperation individual. Thus the authors performed tests in 10 individuals without protection and after with two kinds of ear protections (ear plug and ear muffs), to get the threshold limit value in each of the 3 stages. For this, the research used an electrophysical exam, normally used in speech therapy, named ASSR (auditory steady-state response). The principle of this exam is put on individual’s head 3 electrodes, to capture electrical signs directly in auditory nerve. In summary, the authors presented the final results. The method proposed by ANSI (American National Standards Institute) indicated an attenuation of 27.6 dB for ear plugs, while the value found in this work was 16 dB; and for ear muffs, the ANSI method indicated 29.8 dB while the value found here was 28.5 dB.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main purpose of this study was to analyze the effect of the pedaling cadence (500 × 100 rpm) on the heart rate (HR) and the blood lactate response during incremental and constant workload exercises in active individuals. Nine active male individuals (20.9 ± 2.9 years old; 73.9 ± 6.5 kg; 1.79 ± 0.9 m) were submitted to two incremental tests, and to 6-8 constant workload tests to determine the intensity corresponding to the maximal steady state lactate (MLSSintens) in both cadences. The maximal power (Pmax) attained during the incremental test, and the MLSSintens were significantly lower at 100 rpm (240.9 ± 12.6 W; 148.1 ± 154.W) compared to 50 rpm (263.9 ± 18.6 W; 186.1 ± 21.2 W), respectively. The HRmax did not change between cadences (50 rpm = 191.1 ± 8.8 bpm; 100 rpm = 192.6 ± 9.9 bpm). Regardless the cadence, the HRmax percentage (70, 80, 90, and 100%) determined the same lactate concentrations during the incremental test. However, when the intensity was expressed in Pmax percentage or in absolute power, the lactate and the HR values were always higher at highest cadences. The HR corresponding to MLSSintens was similar between cadences (50 rpm = 162.5 ± 9.1 bpm; 100 rpm = 160.4 ± 9.2 bpm). Based on these results, it can be conclude that regardless the cadence employed (50 × 100 rpm), the use of the HR to individualize the exercise intensity indicates similar blood lactate responses, and this relationship is also kept in the exercise of constant intensity performed at MLSSintens. On the other hand, the use of the Pmax percentages depend on the cadence used, indicating different physiological responses to a same percentage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to validate the lactate minimum test as a specific aerobic evaluation protocol for table tennis players. Using the frequency of 72 balls·min-1 for 90 sec, an exercise-induced metabolic acidosis was determined in 8 male table tennis players. The evaluation protocol began with a frequency of 40 balls·min-1 followed by an increase of 8 balls·min-1 every 3 min until exhaustion. The mean values that corresponded to the subjects' lactate minimum (Lacmin) were equal to 53.1 ± 1.5 balls·min-1 [adjusted for the time test (Lacmin_time)] and 51.6 ± 1.6 balls·min-1 [adjusted for the frequency of balls (Lacmin_Freq)], which resulted in a high correlation between the two forms of adjustment (r = 0.96 and (P = 0.01). The mean maximum lactate steady state (MLSS) was 52.6 ± 1.6 balls·min-1. Pearson's correlations between Lacmin_time vs. MLSS and Lacmin_freq vs. MLSS were statistically significant (P = 0.03 and r = 0.86, P = 0.03 and r = 0.85, respectively). These findings indicate that the Lacmin test predicts MLSS. Therefore, it is an excellent method to obtain the athletes' anaerobic threshold. Also, there is the advantage that it can be performed in 1 day in the game area. However, the Lacmin value does not depend on the Lacpeak value.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tegtbur et al. [23] devised a new method able to estimate the intensity at maximal lactate steady state termed lactate minimum test. According to Billat et al. [7], no studies have yet been published on the affect of training on highest blood lactate concentration that can be maintained over time without continual blood lactate accumulation. Therefore, the aim of the present study was to verify the effect of soccer training on the running speed and the blood lactate concentration (BLC) at the lactate minimum test (Lac(min)). Thirteen Brazilian male professional soccer players, all members of the same team playing at National level, volunteered for this study. Measurements were carried out before (pre) and after (post) eight weeks of soccer training. The Lac(min) test was adapted to the procedures reported by Tegtbur et al. [23]. The running speed at the Lac(min) test was taken when the gradient of the line was zero. Differences in running speed and blood lactate concentration at the Lac(min) test before (pre) and after (post) the training program were evaluated by Student's paired t-test. The training program increased the running speed at the Lac(min) test (14.94 +/- 0.21 vs. 15.44 +/- 0.42* km(.)h(-1)) and the blood lactate concentration (5.11 +/- 2.31 vs. 6.93 +/- 1.33* mmol(.)L(-1)). The enhance in the blood lactate concentration may be explained by an increase in the lactate/H+ transport capacity of human skeletal muscle verified by other authors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The break point of the curve of blood lactate vs exercise load has been called anaerobic threshold (AT) and is considered to be an important indicator of endurance exercise capacity in human subjects. There are few studies of AT determination in animals. We describe a protocol for AT determination by the lactate minimum test in rats during swimming exercise. The test is based on the premise that during an incremental exercise test, and after a bout of maximal exercise, blood lactate decreases to a minimum and then increases again. This minimum value indicates the intensity of the AT. Adult male (90 days) Wistar rats adapted to swimming for 2 weeks were used. The initial state of lactic acidosis was obtained by making the animals jump into the water and swim while carrying a load equivalent to 50% of body weight for 6 min (30-s exercise interrupted by a 30-s rest). After a 9-min rest, blood was collected and the incremental swimming test was started. The test consisted of swimming while supporting loads of 4.5, 5.0, 5.5, 6.0 and 7.0% of body weight. Each exercise load lasted 5 min and was followed by a 30-s rest during which blood samples were taken. The blood lactate minimum was determined from a zero-gradient tangent to a spline function fitting the blood lactate vs workload curve. AT was estimated to be 4.95 ± 0.10% of body weight while interpolated blood lactate was 7.17 ± 0.16 mmol/l. These results suggest the application of AT determination in animal studies concerning metabolism during exercise.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo do presente estudo foi avaliar a aptidão aeróbia em testes de caminhada com carga externa aplicada por meio da inclinação da esteira, a partir da relação não linear entre inclinação da esteira e tempo até a exaustão em velocidade fixa. Doze indivíduos do gênero masculino com 23,2 ± 2,7 anos de idade, 74,0 ± 7,9kg de massa corporal e 23,7 ± 2,5kg·(m²)-1 de IMC, realizaram duas etapas de testes de caminhada em esteira ergométrica com velocidade fixa de 5,5km·h-1 em todos os testes e sobrecarga de intensidade aplicada por meio de inclinação da esteira (%). A etapa 1 consistiu de três testes retangulares até a exaustão voluntária, nas intensidades de 18%, 20% e 22% de inclinação, para determinação dos parâmetros do modelo de potência crítica por dois modelos lineares e um hiperbólico. A etapa 2 consistiu na determinação da intensidade correspondente ao máximo estado estável de lactato sanguíneo (MEEL). ANOVA demonstrou que o modelo hiperbólico (15,4 ± 1,1%) resultou em estimativa significativamente menor que os outros dois modelos lineares inclinação-tempo-1 (16,0 ± 1,0%) e hiperbólico linearizado tempo-1-inclinação (15,9 ± 1,0%), porém, houve alta correlação entre os modelos. Os dois modelos lineares superestimaram a intensidade do MEEL (14,1 ± 1,4%), e o modelo hiperbólico, mesmo sem diferença estatística, apresentou fraca correlação, com baixa concordância em relação ao MEEL. Conclui-se que a relação inclinação-tempo até a exaustão, em testes de caminhada, não permitem a estimativa de intensidade de exercício suportável por longo período de tempo.