219 resultados para linearity


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

When the electro-optic and acousto-optic effects are combined into a single device, the resulting acousto-electro-optic (AEO) modulator shows improved flexibility to overcome some limitations of the individual modulators or their cascade combinations. By using optical interferometry, it is possible to investigate the AEO modulator behavior as a function of this applied voltage. By this way, a lithium niobate AEO modulator is positioned in one of the arms of a Mach-Zehnder interferometer and operates at 62 MHz frequency, which constitutes the intermediate frequency of the heterodyne interferometer. Operating the AEO modulator in the acousto-optic small diffraction efficiency regime, the photodetected signal amplitude and phase are analyzed, and the induced phase shift, transmission curve and linearity response are obtained. The experimental results show good agreement with that expected from the coupled-mode theory. The possibility of linear control of the optical phase shift by the external voltage, from 0 to 2 p radians, is demonstrated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The research trend for harvesting energy from the ambient vibration sources has moved from using a linear resonant generator to a non-linear generator in order to improve on the performance of a linear generator; for example, the relatively small bandwidth, intolerance to mistune and the suitability of the device for low-frequency applications. This article presents experimental results to illustrate the dynamic behaviour of a dual-mode non-linear energy-harvesting device operating in hardening and bi-stable modes under harmonic excitation. The device is able to change from one mode to another by altering the negative magnetic stiffness by adjusting the separation gap between the magnets and the iron core. Results for the device operating in both modes are presented. They show that there is a larger bandwidth for the device operating in the hardening mode compared to the equivalent linear device. However, the maximum power transfer theory is less applicable for the hardening mode due to occurrence of the maximum power at different frequencies, which depends on the non-linearity and the damping in the system. The results for the bi-stable mode show that the device is insensitive to a range of excitation frequencies depending upon the input level, damping and non-linearity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Atualmente, diante das técnicas atuais, a manometria tem sido relegada a plano secundário durante a cateterização cardíaca. No entanto, ainda fornece importantes informações para identificação e avaliação das doenças cardiovasculares. Os dados coletados durante os exames possibilitam a obtenção de variáveis quantitativas e qualitativas, as quais podem ser comparadas aos padrões normais. Os sistemas manométricos são compostos por transdutor, amplificador e registrador, que, em conjunto, devem espelhar com fidelidade a morfologia e os valores das variáveis analisadas. Para atingir esse objetivo, é necessário desempenho adequado de todos os componentes. Se uma determinada informação é de extrema relevância, o operador deve gastar tempo suficiente para obtê-la de maneira inequívoca. Assim, o operador deve estar familiarizado com os sistemas manométricos e com as fontes de erro relacionadas com as técnicas de registro, cateteres, conectores e fluidos. Com os fundamentos analisados neste manuscrito, salientamos que deve ser dispensada atenção às ondas de pressão usadas nas interpretações da fisiopatologia das doenças cardiovasculares.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The pharmacokinetics of enrofloxacin (ENRO), a fluoroquinolone antimicrobial agent, was studied in male broiler chickens (Cobb) after single oral administration of 10 mg of ENRO/kg b.w. A high-performance liquid chromatography-photodiode array detector (DAD) (HPLC-DAD) method was developed and validated and used for quantitation of ENRO and its major metabolite ciprofloxacin in plasma. The HPLC analyses were carried out using a cationic-octadecyl mixed column and 0.05 mol/L phosphate buffer (pH 2.5)/acetonitrile as mobile phase. The sample preparation of plasma consisted of the precipitation of proteins followed by solid phase extraction on cationic-octadecyl mixed cartridges. The method was validated considering linear range, linearity, selectivity, sensitivity, limit of detection (LOD), limit of quantitation (LOQ), intra- and inter-day precisions and accuracy. The LOD and LOQ for both fluoroquinolones were 60 and 200 ng/mL for plasma. The plasma concentration vs. time graph was characteristic of a two-compartment open model. The maximal plasma concentration of 1.5 +/- 0.2 mg/mL was achieved at 9 +/- 2 h. The elimination half-life and the mean residence time of ENRO were 1.5 +/- 0.2 and 15.64 h, respectively. The area under the concentration-time curve was calculated as 35 +/- 4 mg(.)h/mL.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present article reflects about the concepts of linearity, space and acoustic complexity in the definition of sound grouping as a criticism to the linear concept of phraseology mainly when applied to the music of imitative texture or of complex simultaneities. It takes as examples works by Bach, Josquin des Prez and a fragment of "Lontano" by Ligeti, to study them in two distinct dimensions, simultaneous and interconnected: the acoustic dimension with its entire spectral complexity and the relational dimension which establishes the interaction among the figures in voices and texture layers with some kind of acoustic and structural simultaneity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Um método de correção de interferência espectral e de transporte é proposto, e foi aplicado para minimizar interferências por moléculas de PO produzidas em chama ar-acetileno e de transporte causada pela variação da concentração de ácido fosfórico. Átomos de Pb e moléculas de PO absorvem a 217,0005 nm, então Atotal217,0005 nm = A Pb217,0005 nm + A PO217,0005 nm. Monitorando o comprimento de onda alternativo de PO em 217,0458 nm, é possível calcular a contribuição relativa de PO na absorbância total a 217,0005 nm: A Pb217,0005 nm = Atotal217,0005 nm - A PO217,0005 nm = Atotal217,0005 nm - k (A PO217,0458 nm). O fator de correção k é a razão entre os coeficientes angulares de duas curvas analíticas para P obtidas a 217,0005 e 217,0458 nm (k = b217,0005 nm/b217,0458 nm). Fixando-se a taxa de aspiração da amostra em 5,0 ml min-1, e integrando-se a absorbância no comprimento de onda a 3 pixels, curvas analíticas para Pb (0,1 - 1,0 mg L-1) foram obtidas com coeficientes de correlação típicos > 0,9990. As correlações lineares entre absorbância e concentração de P nos comprimentos de onda 217,0005 e 217,0458 foram > 0,998. O limite de detecção de Pb foi 10 µg L-1. O método de correção proposto forneceu desvios padrão relativos (n=12) de 2,0 a 6,0%, ligeiramente menores que os obtidos sem correção (1,4-4,3%). As recuperações de Pb adicionado às amostras de ácido fosfórico variaram de 97,5 a 100% (com correção pelo método proposto) e de 105 a 230% (sem correção).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Observando a literatura pode ser verificado um crescente número de trabalhos que determinam potenciais contaminantes presentes em matrizes de interesse ambiental. É importante ressaltar que quando se estuda o ambiente, os dados analíticos são uma das ferramentas usadas para se avaliar a extensão dos problemas observados que conseqüentemente influenciam as tomadas de decisão. Assim a confiabilidade desses dados é de extrema importância. Neste contexto, este trabalho visa avaliar a confiabilidade analítica das determinações de Carbono Orgânico Total (COT), ferramenta empregada no monitoramento da matéria orgânica em diversos estudos ambientais. Para essa avaliação foram analisados alguns parâmetros de desempenho como limite de detecção e quantificação, repetibilidade e linearidade.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A eficiência de métodos para análise de 5-hidroximetilfurfural por cromatografia líquida de alta eficiência com detecção na região do ultravioleta e determinação de sacarose, glicose e frutose por cromatografia líquida com detecção por índice de refração foi avaliada. Após otimização das condições analíticas, os principais parâmetros de validação (linearidade, limite de quantificação, limite de detecção, recuperação, sensibilidade e precisão) foram determinados e demonstraram que os procedimentos analíticos podem ser aplicados para o controle do processo de produção de poli(3-hidroxibutirato).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)