368 resultados para implant fracture


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fatigue, corrosion and wear resistance are important parameters in aircraft components development as landing gear. High strength/weight ratio and effective corrosion resistance make of titanium alloys an alternative choice to replace steel and aluminum alloys. However, titanium alloys have poor tribological properties, which reduce devices performance under friction. PVD coatings tribological systems has been increased due to their attractive mechanical properties as low environmental impact, low friction coefficient, low wear rate and hardness up to 2000 HV.In this study the influence of TiN deposited by PVD on the fatigue strength of Ti-6Al-4V alloy was evaluated. Comparison of fatigue strength of coated specimens and base material shows also a decrease when parts are coated. It was observed that the influence is more significant in high cycle fatigue tests. Scanning electron microscopy technique (SEM) was used to observe crack origin sites and fracture features. (C) 2010 Published by Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. The postoperative acute renal failure (ARF) incidence in different kinds of surgery has rarely been studied. Age, cardiac dysfunction, previous renal dysfunction, intraoperative hypoperfusion, and use of nephrotoxic medications are mentioned as risk factors for ARF at the postoperative period. The postoperative ARF definition was based on the creatinine increase by the RIFLE classification (R = risk, I = injury, F = failure, L = loss, E = end stage), which corresponds to a 1.5 creatinine increase, two to three times, respectively, above the basal value. This study aimed to evaluate the postoperative ARF incidence in elderly patients who underwent femur fracture surgery under subarachnoid anesthesia and stratify it by the RIFLE criteria. Methods. Ninety patients older than 65 years under spinal anesthesia with fixed dosage of 15 mg of 0.5% isobaric bupivacaine associated with morphine 50 g were studied. Immediate postoperative creatinine was considered basal and compared with maximal creatinine evaluated at 24, 48, and 72 postoperative hours. Results. The mean age of the patients was 80.27 years. ARF incidence was 24.44% and stratified this way: R = 21.11% and I = 3.33%. Conclusions. In conclusion, the postoperative ARF incidence after femur fracture surgery in patients over 65 years was 24.44%. By analyzing the stratification based on the RIFLE classification, the incidence was categorized as Risk (R) = 21.11% and Injury (I) = 3.33%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. The best way to study compensatory lung growth (CLG) is in a transplant without rejection. Since immunosuppressive drugs may influence CLG, it is better to not use them. Therefore we studied CLG in a reimplant of only one lobe after its removal. The objective was to compare lobar transplant CLG with CLG after lobectomy.Methods. Forty eight dogs were distributed in three groups: G1 = control, G2 = left cranial lobectomy, and G3 = left pneumonectomy with reimplantation of the caudal lobe. Five months after surgery the animals underwent lung scintigraphy and were sacrificed for morphometric study.Results. There was no correlation between scintigraphy and lung mass or lung volume. There was both mass and residual volume CLG in the operated groups, both contralateral and ipsilateral to surgery. There was no compensation for total lung capacity or compliance in the remaining caudal lobe (G2) or the reimplanted caudal lobe (G3) at 5 months after surgery. There was more damage in the reimplanted lobe. As previous studies have shown that CLG starts with increased mass and residual volume and compliance is compensated later. This study seemed to document the beginning of CLG, with lung compliance being the limiting factor of CLG at 5 months.Conclusion. There was CLG in both the reimplanted lobe and the contralateral lung, but compliance was still reduced. CLG was similar in both groups, but in the implanted lobe compliance was more prejudiced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: This prospective experimental study evaluated the surgical procedure and results of modular hybrid total hip arthroplasty in dogs.Methods: Ten skeletally mature healthy mongrel dogs with weights varying between 19 and 27 kg were used. Cemented modular femoral stems and uncemented porous-coated acetabular cups were employed. Clinical and radiographic evaluations were performed before surgery and at 30, 60, 90, 120, 180 and 360 days post-operation.Results: Excellent weight bearing was noticed in the operated limb in seven dogs. Dislocation followed by loosening of the prosthesis was noticed in two dogs, which were therefore properly treated with a femoral head osteotomy. Femoral fracture occurred in one dog, which was promptly treated with full implant removal and femoral osteosynthesis.Conclusions: The canine modular hybrid total hip arthroplasty provided excellent functionality of the operated limb.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o efeito do laser de baixa intensidade sobre a contração da pseudocápsula que ocorre ao redor de implantes de silicone. MÉTODOS: 60 ratos machos divididos em dois grupos receberam implante de silicone. Grupo I: implante no subcutâneo da região dorsal, sem tratamento após a cirurgia; Grupo II: animais receberam sete sessões de irradiação com laser de baixa intensidade após o implante. Trinta, 60 e 180 dias após a cirurgia, foi feita a tonometria dos implantes, em seguida, os animais foram sacrificados, removendo-se o material de estudo que foi preparado para exame histológico, avaliando-se morfometricamente a espessura da pseudocápsula e a reação inflamatória. A análise estatistica pela técnica da Análise de Variância e Teste de Tukey (P<0.0 5). RESULTADOS: Pressões significativamente menores foram encontradas nos animais do grupo Grupo II. O estudo histológico não mostrou diferença significativa entre os grupos, destacando-se apenas maior quantidade de vasos intumescidos no Grupo II. A espessura da pseudocápsula foi menor no Grupo II. CONCLUSÃO: O laser de baixa intensidade altera o processo de reparação tecidual ao redor dos implantes, sugerindo que o mesmo possa ser útil para a modelação das contraturas que se estabelecem ao redor dos implantes de silicone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Superficial digital flexor tendonitis is an important cause of lameness in horses and its incidence ranges from 13% to 30%, depending on the horse's activity. This injury can occur in yearlings and compromise its carriers by reinjury or even impossibility to return to athletic life. In spite of the long period required for tendon repair, the scar tissue presents lack of elasticity and stiffness. As current treatment strategies produce only marginal results, there has been great interest in research of therapies that influence the quality or the speed of tendon repair. Stem cell therapy has shown promising results in degenerative diseases and cases of deficient healing processes. This study aims to evaluate the influence of autologous mesenchymal bone marrow stem cells in tendon healing, comparing treated and non-treated tendons. Superficial digital flexor tendonitis lesions were induced by collagenase infiltration in both forelimbs of 6 horses, followed by autologous implant in one of the forelimbs of each animal. The horses were evaluated using clinical, ultrasonographic, histopathologic, and immunohistochemical parameters. Tendon biopsies were performed at Day 48. Results found in the treatment group, such as high inflammatory cells infiltration, extracellular matrix synthesis, reduced amount of necrosis areas, small increase in cellular proliferation (KI-67/MIB-1), and low immunoreactivity to transforming growth factor P I, suggested the acceleration of tendon repair in this group. Further studies should be conducted in order to verify the influence of this treatment on later phases of tendon repair. Overall, after analysis of the results, we can conclude that cellular therapy with the mononuclear fraction of bone marrow has accelerated tendon repair at 48 days after treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo do estudo foi avaliar a eficácia do fixador esquelético pino-resina, configuração tipo II, coadjuvado pelo enxerto ósseo esponjoso autólogo, no tratamento das complicações secundárias à imobilização inadequada de fraturas do rádio e ulna em 10 cães, com peso entre 1,8 e 33,6 kg. Detectou-se não-união (n=4), osteomielite (n=1), má-união (n=1), falência ou quebra de implante (n=4), sendo 60% das lesões referente ao uso prévio de pino intramedular no rádio. A montagem do fixador foi realizada com transfixação de pinos lisos em sua maioria angulados, cujas extremidades excedentes foram dobradas e estabilizadas com resina acrílica. em todos os casos, utilizou-se enxerto esponjoso autólogo fresco, após debridamento do foco de fratura. O tempo de permanência do aparelho variou entre 45 dias e 5 meses e a maior complicação foi o afrouxamento dos pinos transfixantes. A consolidação das fraturas ocorreu por formação de calo periosteal de mínimo a moderado, indicando boa rigidez da montagem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A boa constrictor was presented with a short oblique compound fracture of the rostral third of the right maxilla. The fracture was reduced and biomaterial was placed around the fracture. A computed tomography scan at 1.5 mo post-surgery showed that the fracture had healed with slight displacement of the bone fragments.