39 resultados para human-computer visualization
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciência da Computação - IBILCE
Resumo:
INTRODUCTION: Biological age is an important parameter for growth and development assessment. It can be evaluated through the observation of radiographic changes in skeletal maturation of cervical vertebrae. OBJECTIVE: This study aims to: a) verify if there is correlation between growth curve and the stages of bone age of animals used in laboratories, by evaluating radiographs of the cervical vertebrae; b) correlate these stages with their correspondents in humans. METHODS: 35 Wistar rats were evaluated for a period of 160 days, starting at day 22nd (weaning), with cross sections for periodic weighing, length measurement and digital radiography. Radiographs of the cervical vertebrae (C2 and C3) were measured by means of a computer program (Radio IMP). Data were submitted to statistical analysis (ANOVA) and Pearson correlation. RESULTS: Growth spurt was characterized by fast increasing in weight and length. Through ANOVA, differences were observed in the cervical measurements between days 22, 97, 127, 157, 187 and 217 (p <0.001). A high correlation was found between increasing in body length and weight, as well as in cervical vertebrae height (r = 0.86). Increments in concavities of vertebrae were also observed, similar to humans. CONCLUSIONS: There is correlation between body growth and maturation of cervical vertebrae in rats. Despite the continuous development of concavities, it was not possible to clearly identify the 5/6 stages as in studies of cervical vertebrae maturation in humans.
Resumo:
The aim of this study was to evaluate the accuracy of virtual three-dimensional (3D) reconstructions of human dry mandibles, produced from two segmentation protocols (outline only and all-boundary lines).Twenty virtual three-dimensional (3D) images were built from computed tomography exam (CT) of 10 dry mandibles, in which linear measurements between anatomical landmarks were obtained and compared to an error probability of 5 %.The results showed no statistically significant difference among the dry mandibles and the virtual 3D reconstructions produced from segmentation protocols tested (p = 0,24).During the designing of a virtual 3D reconstruction, both outline only and all-boundary lines segmentation protocols can be used.Virtual processing of CT images is the most complex stage during the manufacture of the biomodel. Establishing a better protocol during this phase allows the construction of a biomodel with characteristics that are closer to the original anatomical structures. This is essential to ensure a correct preoperative planning and a suitable treatment.
Resumo:
The research presents as its central theme the study of the bibliographic record conversion process. The object of study is framed by an understanding of analogic bibliographic record conversion to the Bibliograhpic MARC21 format, based on a syntactic and semantic analysis of records described according to descriptive metadata structure standards and content standards. The objective of this research the objective is to develop a theoretical-conceptual model of syntactic and semantic of bibliographic records, from Linguistic studies of Saussure and Hjelmslev of manifestations of human language, which subsidizes the development of a computacional interpreter, focused to the conversion of bibliographic records to MARC21 Bibliographic Format, which can be confirmed both the semantic value of the informational resource represented as the reliability of the representation. Given the aforementioned objectives, the methodological trajectory of the research is based on the qualitative approach, of an exploratory, descriptive and experimental nature, and with recourse to the literature. Contributions on the theoretical plane can be envisaged regarding the development of questions inherent to the syntactic and semantic aspects of bibliographic records, and by involving, at the same time, interdisciplinarity between Information Science, Computer Science and Linguistics. Contributions to the practical field are identified by the fact the study covers the development of the Scan for MARC, a computational interpreter that can be adopted by any institution that wishes to use the conversion procedure for bibliographic record databases to the MARC21 Bibliographic Format from description and visualization schemes of bibliographic records (AACR2r and ISBD), an aspect of the research which is considered innovative.
Resumo:
This paper reports a research to evaluate the potential and the effects of use of annotated Paraconsistent logic in automatic indexing. This logic attempts to deal with contradictions, concerned with studying and developing inconsistency-tolerant systems of logic. This logic, being flexible and containing logical states that go beyond the dichotomies yes and no, permits to advance the hypothesis that the results of indexing could be better than those obtained by traditional methods. Interactions between different disciplines, as information retrieval, automatic indexing, information visualization, and nonclassical logics were considered in this research. From the methodological point of view, an algorithm for treatment of uncertainty and imprecision, developed under the Paraconsistent logic, was used to modify the values of the weights assigned to indexing terms of the text collections. The tests were performed on an information visualization system named Projection Explorer (PEx), created at Institute of Mathematics and Computer Science (ICMC - USP Sao Carlos), with available source code. PEx uses traditional vector space model to represent documents of a collection. The results were evaluated by criteria built in the information visualization system itself, and demonstrated measurable gains in the quality of the displays, confirming the hypothesis that the use of the para-analyser under the conditions of the experiment has the ability to generate more effective clusters of similar documents. This is a point that draws attention, since the constitution of more significant clusters can be used to enhance information indexing and retrieval. It can be argued that the adoption of non-dichotomous (non-exclusive) parameters provides new possibilities to relate similar information.
Resumo:
The human dentition is naturally translucent, opalescent and fluorescent. Differences between the level of fluorescence of tooth structure and restorative materials may result in distinct metameric properties and consequently perceptible disparate esthetic behavior, which impairs the esthetic result of the restorations, frustrating both patients and staff. In this study, we evaluated the level of fluorescence of different composites (Durafill in tones A2 (Du), Charisma in tones A2 (Ch), Venus in tone A2 (Ve), Opallis enamel and dentin in tones A2 (OPD and OPE), Point 4 in tones A2 (P4), Z100 in tones A2 ( Z1), Z250 in tones A2 (Z2), Te-Econom in tones A2 (TE), Tetric Ceram in tones A2 (TC), Tetric Ceram N in tones A1, A2, A4 (TN1, TN2, TN4), Four seasons enamel and dentin in tones A2 (and 4SD 4SE), Empress Direct enamel and dentin in tones A2 (EDE and EDD) and Brilliant in tones A2 (Br)). Cylindrical specimens were prepared, coded and photographed in a standardized manner with a Canon EOS digital camera (400 ISO, 2.8 aperture and 1/ 30 speed), in a dark environment under the action of UV light (25 W). The images were analyzed with the software ScanWhite©-DMC/Darwin systems. The results showed statistical differences between the groups (p < 0.05), and between these same groups and the average fluorescence of the dentition of young (18 to 25 years) and adults (40 to 45 years) taken as control. It can be concluded that: Composites Z100, Z250 (3M ESPE) and Point 4 (Kerr) do not match with the fluorescence of human dentition and the fluorescence of the materials was found to be affected by their own tone.
Resumo:
Diottix(r) was calibrated at 25 Hz to achieve the frequency indicated in literature as being effective to mobilize the airways secretions. However, the amplitude and frequency of the waves generated by the equipment in different regions of the chest still need to be investigated. The objective of this study was to analyze the frequency and amplitude of waves generated by Diottix(r) in chests of healthy subjects. Diottix(r) was used in the anterior and posterior regions of the chest. The mechanical waves were captured using stethoscopes connected to electret microphones, which were connected to a digital oscilloscope. Frequency and amplitude data were recorded by the stethoscope, positioned in six points in the anterior region and six in the posterior region of the chest, following the positions commonly used in pulmonary auscultation. Signals were recorded and transferred to a computer with software for their analysis. The frequency of waves did not present a significant change (from 24.9 to 26.4 Hz). The wave amplitude in the anterior versus the posterior region in each area of the lung, the upper, middle and lower, had differences. Diottix(r) produces frequencies in the chest according to the calibrated; thus, it can be a complementary resource to bronchial hygiene maneuvers. The amplitudes of waves seem to be affected by other structures like bone parts and heart.