33 resultados para estimación por intervalo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Geociências e Meio Ambiente - IGCE

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The rest interval between bouts is a crucial variable of resistance training to ensure recovery of neuromuscular capacity. Objective: To compare the effect of rest interval between repeated bouts of resistance training on neuromuscular capacity of trained men. Methods: Eight resistance-trained men (21.6 +/- 3.3 years, 75.1 +/- 11.3 kg, 178.2 +/- 6.8 cm) performed two randomized and crossover resistance exercise bouts, repeated with rest interval of 24h or 48h. The bouts consisted of horizontal, inclined and declined bench press performed with five sets of 10 repetitions with an intensity of 70% of one repetition maximum (1RM) for each exercise. Neuromuscular performance post-exercise bout (strength, power and speed), was assessed with an accelerometer (Myotest (R)), with a load of 50% 1RM, in the bench press exercise. Results: Both sessions (24 and 48h) showed significant reduction (P < 0.05) in the neuromuscular capacity (strength, power and speed) post-exercise bout, returning to baseline values within 24h (P> 0.05). Conclusion: The results suggest that the rest interval of 24h is sufficient for recovery of neuromuscular performance in upper limbs of resistance-trained men.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes instrumental strategies for the determination of Mn in a wide range concentration by high-resolution continuum source flame atomic absorption spectrometry technique (HR-CS F AAS) by means of different atomic lines (primary at 279.482 nm, secondary at 403.075 nm and alternative at 209.250 nm). These lines provided complementary concentration intervals, and large sample dilutions became unnecessary. The proposed method was applied to tap water, metal alloy certified material and foliar fertilizer. Accuracy for secondary line were evaluated by tests of significance (t Student test) with reference materials from the Institute of Technological Research of São Paulo, and the results were in agreement at the 95% confidence level. For primary and alternative lines, recovery is were in the 84-116% range and the RSD were 6.1% for all wavelengths. Analytical curves in the 0.1 - 2.0 mg L-1 (279.482 nm), 2.0 - 25 mg L-1 (403.075 nm), 25 - 500 mg L-1 (209.250 nm) intervals were obtained with linear correlation coefficient better than 0.9991. The detection limits were 3.3x10-3 mg L-1 (279.482 nm), 7.4 x 10-3 mg L-1 (403.075 nm), 3.9 mg L- 1 (209.250 nm). The found Mn concentrations were < 3.3x10-3 mg L-1 (tap water), 1.00 ± 0.04 (% m/m) (alloy IPT 25), 7235 ± 175 mg L-1 (foliar fertilizer 1), 4990 ± 132 mg L-1 (foliar fertilizer 2). A method was developed to detect interference of Fe in the Mn primary line (279.482 nm) using the ratio of absorbances of other lines of the triplet (279.827 nm and 280,108 nm).