198 resultados para edentulous


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to compare the stress distribution induced by posterior functional loads on conventional complete dentures and implant-retained overdentures with different attachment systems using a two-dimentional Finite Element Analysis (FEA-2D). Three models representative of edentulous mandible were constructed on AutoCAD software; Group A (control), a model of edentulous mandible supporting a complete denture; Group B, a model of edentulous mandible supporting an overdenture over two splinted implants connected with the bar-clip system; Group C, a model of edentuluos mandible supporting an overdenture over two unsplinted impants with the O-ring system. Evaluation was conducted on Ansys software, with a vertical force of 100 N applied on the mandibular left first molar. When the stress was evaluated in supporting tissues, groups B (51.0 MPa) and C (52.6 MPa) demonstrated higher stress values than group A (10.1 MPa). Within the limits of this study, it may be conclued that the use of an attachment system increased stress values; furthermore, the use of splinted implants associated with the bar-clip attachment system favoured a lower stress distribution over the supporting tissue than the unsplinted implants with an O-ring abutment to retain the manibular overdenture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This finite element analysis compared stress distribution on complete dentures and implant-retained overdentures with different attachment systems. Four models of edentulous mandible were constructed: group A (control), complete denture; group B, overdenture retained by 2 splinted implants with bar-clip system; group C, overdenture retained by 2 unsplinted implants with o'ring system; and group D, overdenture retained by 2 splinted implants with bar-clip and 2 distally placed o'ring system. Evaluation was performed on Ansys software, with 100-N vertical load applied on central incisive teeth. The lowest maximum general stress value (in megapascal) was observed in group A (64.305) followed by groups C (119.006), D (258.650), and B (349.873). The same trend occurred it) supporting tissues with the highest stress value for cortical bone. Unsplinted implants associated with the o'ring attachment system showed the lowest maximum stress values among all overdenture groups. Furthermore, o'ring system also improved stress distribution when associated with bar-clip system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to evaluate and correlate quality of life (QoL), and stimulus perception of complete denture users, before and after the insertion of new prostheses. We selected 60 patients using bimaxillary complete conventional dentures who needed to replace their prostheses. During anamnesis, we collected demographic data and applied the Oral Health Impact Profile for Edentulous Patients (OHIP-EDENT) questionnaire and stimulus perception questionnaire (PERCEPTION). Before installation of new prostheses, the patients responded to OHIP-EDENT questionnaire, and on the day of installation, they responded to PERCEPTION questionnaire. At the patients 3-month follow-up, we re-administered the OHIP-EDENT and PERCEPTION questionnaires. The Wilcoxon and MacNemar tests were used to compare patient responses between the time points analysed. Most of the OHIP-EDENT items showed a highly significant impact of the new prostheses on oral health (P = 0.003). The PERCEPTION questionnaire data indicated that the patients experienced significant improvements (P < 0.05) in terms of their sensations with the new prostheses. Cross-lagged data analysis did not show any causality between the OHIP-EDENT and PERCEPTION questionnaires (ZPF test, P = 0.772). We concluded that the treatment was effective with respect to the patients QoL and their adaptation to the new prostheses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purposes of this study were to photoelastically measure the biomechanical behavior of 4 implants retaining different cantilevered bar mandibular overdenture designs and to compare a fixed partial denture (FPD). A photoelastic model of a human edentulous mandible was fabricated, which contained 4 screw-type implants (3.75 x 10 mm) embedded in the parasymphyseal area. An FPD and 3 overdenture designs with the following attachments were evaluated: 3 plastic Hader clips, 1 Hader clip with 2 posterior resilient cap attachments, and 3 ball/O-ring attachments. Vertical occlusal forces of 100 N were applied between the central incisor and unilaterally to the right and left second premolars and second molars. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. The results showed that the anterior loading, the overdenture with 3 plastic Hader clips, displayed the largest stress concentration at the medium implant. With premolar loading, the FPD and overdenture with 3 plastic Hader clips displayed the highest stresses to the ipsilateral terminal implant. With molar loading, the overdenture with 3 ball/O-ring attachments displayed the most uniform stress distribution in the posterior edentulous ridge, with less overloading in the terminal implant. It was concluded that vertical forces applied to the bar-clip overdenture and FPD created immediate stress patterns of greater magnitude and concentration on the ipsilateral implants, whereas the ball/O-ring attachments transferred minimal stress to the implants. The increased cantilever in the FPD caused the highest stresses to the terminal implant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to use two-dimensional finite element method to evaluate the displacement and stress distribution transmitted by a distal extension removable partial denture (DERPD) associated with an implant placed at different inclinations (0, 5, 15, and 30 degrees) in the second molar region of the edentulous mandible ridge. Six hemimandibular models were created: model A, only with the presence of the natural tooth 33; model B, similar to model A, with the presence of a conventional DERPD replacing the missing teeth; model C, similar to the previous model, with a straight implant (0 degrees) in the distal region of the ridge, under the denture base; model D, similar to model C, with the implant angled at 5 degrees in the mesial direction; model E, similar to model C, with the implant angled at 15 degrees in the mesial direction; and model F, similar to ME, with the implant angled at 30 degrees in the mesial direction. The models were created with the use of the AutoCAD 2000 program (Autodesk, Inc, San Rafael, CA) and processed for finite element analysis by the ANSYS 8.0 program (Swanson Analysis Systems, Houston, PA). The force applied was vertical of 50 N on each cusp tip. The results showed that the introduction of the RPD overloaded the supporting structures of the RPD and that the introduction of the implant helped to relieve the stresses of the mucosa alveolar, cortical bone, and trabecular bone. The best stress distribution occurred in model D with the implant angled at 5 degrees. The use of an implant as a support decreased the displacement of alveolar mucosa for all inclinations simulated. The stress distribution transmitted by the DERPD to the supporting structures was improved by the use of straight or slightly inclined implants. According to the displacement analysis and von Mises stress, it could be expected that straight or slightly inclined implants do not represent biomechanical risks to use.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Transitional implants are indicated for cases in which immediate loading is counter-indicated because a healing period is necessary for osseointegration of the definitive implants. These provisional implants were developed to support an implant-supported fixed prosthesis or overdenture to provide retention, stability, and support. The aim of this article was to conduct a literature review on transitional implants to highlight the characteristics of the transitional implants and their advantages, indications, and contraindications, including the level of osseointegration of such implants according to the functional period. Method and Materials: The present literature review was based on the OldMedline and Medline databases from 1999 to 2010 using the key words "transitional implants" and "temporary implants." Fourteen articles were found: 11 clinical studies or techniques and three histologic and histomorphometric studies. Results: The transitional immediate prostheses were worn by completely and partially edentulous patients. Advantages of transitional implants include complete denture retention, stability, and support; maintenance of chewing, phonetics, and patient comfort; protection of bone grafts; vertical stop during healing period; easy and fast surgical and prosthetic procedures; lower cost in comparison to the definitive implant; and reestablishment of esthetics. The success of transitional implants as conservative treatment for conventional immediate loading is a reality if correctly indicated. Conclusion: Transitional implants are a provisional treatment alternative for completely and partially edentulous patients. However, additional studies are required to evaluate the level of remodeling and repair of the transitional implants under loading. (Quintessence Int 2011; 42: 19-24)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The non-homogenous aspect of periodontal ligament (PDL) has been examined using finite element analysis (FEA) to better simulate PDL behavior. The aim of this study was to assess, by 2-D FEA, the influence of non-homogenous PDL on the stress distribution when the free-end saddle removable partial denture (RPD) is partially supported by an osseointegrated implant. Material and Methods: Six finite element (FE) models of a partially edentulous mandible were created to represent two types of PDL (non-homogenous and homogenous) and two types of RPD (conventional RPD, supported by tooth and fibromucosa; and modified RPD, supported by tooth and implant [10.00x3.75 mm]). Two additional FE models without RPD were used as control models. The non-homogenous PDL was modeled using beam elements to simulate the crest, horizontal, oblique and apical fibers. The load (50 N) was applied in each cusp simultaneously. Regarding boundary conditions the border of alveolar ridge was fixed along the x axis. The FE software (Ansys 10.0) was used to compute the stress fields, and the von Mises stress criterion (sigma vM) was applied to analyze the results. Results: The peak of sigma vM in non-homogenous PDL was higher than that for the homogenous condition. The benefits of implants were enhanced for the non-homogenous PDL condition, with drastic sigma vM reduction on the posterior half of the alveolar ridge. The implant did not reduce the stress on the support tooth for both PDL conditions. Conclusion: The PDL modeled in the non-homogeneous form increased the benefits of the osseointegrated implant in comparison with the homogeneous condition. Using the non-homogenous PDL, the presence of osseointegrated implant did not reduce the stress on the supporting tooth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present study was to conduct a critical literature review about the technique of computer-guided surgery in implantology to highlight the indications, purposes, immediate loading of implants and complications, protocol of fabrication, and functioning of virtual planning software. This literature review was based on OLDMEDLINE and MEDLINE databases from 2002 to 2010 using the key words "computer-guided surgery" and "implant-supported prosthesis." Thirty-four studies regarding this topic were found. According to the literature review, it was concluded that the computer-assisted surgery is an excellent treatment alternative for patients with appropriate bone quantity for implant insertion in complete and partially edentulous arches. The Procera Nobel Guide software (Nobel Biocare) was the most common software used by the authors. In addition, the flapless surgery is advantageous for positioning of implants but with accurate indication. Although the computer-guided surgery may be helpful for virtual planning of cases with severe bone resorption, the conventional surgical technique is more appropriate. The surgical guide is important for insertion of the implants regardless of the surgical technique, and the success of immediate loading after computer-guided surgery depends on the accuracy of clinical and/or laboratorial steps.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the intraexaminer agreement in the detection of the mandibular canal roof (MCR) and mental foramen (MF) in panoramic radiographs. Forty panoramic radiographs of edentulous patients were used. Two calibrated examiners (A and B) read the images 2 times, for both sides independently, under blind conditions. The interval between the readings was 10 days. The intraexaminer agreement in the interpretation of MCR and MF was performed by kappa statistics with linear weighting (x). The intraexaminer agreement for the detection of MCR, in the left side, was good for both examiners (A: kappa = 0.67; B: kappa = 0.71). Related to the right side, it was found to be kappa = 0.47 and kappa = 0.62, respectively to A and B. The intraexaminer agreement for the detection of MF was good for both examiners interpreting the left side (A: kappa = 0.61; B: kappa = 0.63), and in relation to the right side, it was moderate (A: kappa = 0.51) and fair (B: kappa = 0.38). The intraexaminer agreement in the detection of MCR was good and from good to fair in the detection of MF.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of implants to rehabilitation of total edentulous, partial edentulous or single tooth is increasing, it is due to the high rate of success that this type of treatment present. The objective of this study was to analyze the mechanical behavior of different positions of two dental implants in a rehabilitation of 4 teeth in the region of maxilla anterior. The groups studied were divided according the positioning of the implants. The Group 1: Internal Hexagonal implant in position of lateral incisors and pontic in region of central incisors; Group 2: Internal Hexagonal implant in position of central incisors and cantilever of the lateral incisors and Group3 - : Internal Hexagonal implants alternate with suspended elements. The Electronic Speckle Pattern Interferometry (ESPI) technique was selected for the mechanical evaluation of the 3 groups performance. The results are shown in interferometric phase maps representing the displacement field of the prosthetic structure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The aim of the present study was to evaluate clinical and radiographic changes that occur around dental implants inserted in different levels in relation to crestal bone under different restoration protocols.Methods: Thirty-six implants were inserted in the edentulous mandible of six mongrel dogs. Each implant was assigned to an experimental group according to the distance from the top of the implant to the crestal bone: Bone Level (at crestal bone level), Minus 1 (1 mm below crestal bone), or Minus 2 (2 mm below crestal bone). Each hemimandible was submitted to a restoration protocol: conventional (prosthesis was installed 120 days after implant placement, including 30 days with healing cap) or immediate (prosthesis was installed 24 hours after implant placement). Fixed partial prostheses were installed bilaterally in the same day. After 90 days, clinical and radiographic parameters were evaluated.Results: As long as the implants were inserted in more apical positions, the first bone-to-implant contact (fBIC) was positioned more apically (P<0.05). However, the apical positioning of the implants did not influence the ridge loss or the position of the soft tissue margin (PSTM) (P>0.05). In addition, in immediately restored sites, the PSTM was located significantly more coronally than that in conventionally restored sites (P=0.02).Conclusions: Despite the more apical positioning of the fBIC, the height of the peri-implant soft tissues and ridge was not jeopardized. Moreover, the immediate restoration protocol was beneficial to the maintenance of the PSTM. Further studies are suggested to evaluate the significance of these results in longer healing periods.