93 resultados para direct digital radiography


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

INTRODUCTION: Biological age is an important parameter for growth and development assessment. It can be evaluated through the observation of radiographic changes in skeletal maturation of cervical vertebrae. OBJECTIVE: This study aims to: a) verify if there is correlation between growth curve and the stages of bone age of animals used in laboratories, by evaluating radiographs of the cervical vertebrae; b) correlate these stages with their correspondents in humans. METHODS: 35 Wistar rats were evaluated for a period of 160 days, starting at day 22nd (weaning), with cross sections for periodic weighing, length measurement and digital radiography. Radiographs of the cervical vertebrae (C2 and C3) were measured by means of a computer program (Radio IMP). Data were submitted to statistical analysis (ANOVA) and Pearson correlation. RESULTS: Growth spurt was characterized by fast increasing in weight and length. Through ANOVA, differences were observed in the cervical measurements between days 22, 97, 127, 157, 187 and 217 (p <0.001). A high correlation was found between increasing in body length and weight, as well as in cervical vertebrae height (r = 0.86). Increments in concavities of vertebrae were also observed, similar to humans. CONCLUSIONS: There is correlation between body growth and maturation of cervical vertebrae in rats. Despite the continuous development of concavities, it was not possible to clearly identify the 5/6 stages as in studies of cervical vertebrae maturation in humans.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The best way to detect breast cancer is by screening mammography. The mammography equipments are dedicated and require a rigorous quality control in order to have a good quality image and to early detect this disease. The digital equipment is relatively new in the market and there isn’t a national rule for quality control for several types of digital detectors. This study has proposed to compare two different tests manuals for quality control provided by the manufacturers of digital mammography equipments, and also compare them to the “European guidelines for quality assurance in breast cancer screening and diagnosis “(2006). The studied equipments were: Senographe 2000D from General Electric (GE) and the Hologic Selenia Lorad. Both were digital mammography equipments, the GE unit presents an indirect digital system and the other presents a direct digital system. Physical parameters of the image have been studied, such as spatial resolution, contrast resolution, noise, signal-tonoise ratio, contrast-to-noise ratio and modulation transfer function. After that, a study of the importance of quality control and the requirement to implement a Quality Assurance Program has been done. One data collection was done to compare those manual, it was done by checking which tests are indicated and the minimum frequency which they should be conducted in accordance with each manufacturer. The tests were performed by different methodologies and the results were compared. The examined tests were: the breast entrance skin dose, mean glandular dose, contrast-to-noise ratio, signal-to-noise ratio, automatic exposure control and automatic control of density, modulation transfer function, equipment resolution, homogeneity and ghost

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The objective of this study is to evaluate the measurement accuracy of endodontic files obtained by digital and conventional radiographies in primary teeth. Kerr and Hedströen files (# 20), with the reference as the apparent length of tooth, were inserted in the root canal of 18 extracted primary teeth, which were x-rayed by digital and conventional techniques. Measurements from a reference point to the apical end were carried out by an experienced operator twice in a week. An electronic ruler was used for the digital method and a caliper was used for the conventional method. The data were subjected to Pearson correlation test and Student´s t test (p = 0.05). The correlation between the first and the second measurements was r = 0.99, regardless the type of file and method. Comparing the measurements within the methods, the agreement was r = 0.96 for Kerr and r = 0.95 for Hedströen files. The values of length files in the digital radiographies were statistically lower than that obtained in the conventional radiographies (p = 0.02). However, the values obtained by the two methods were statistically similar to real length of teeth for Kerr files (p = 0.29) and for Hedströen files (p = 0.18). The digital radiography was a more trustful method to obtain the lengths of endodontic files.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this study was to evaluate whether digitized images obtained from periapical radiographs taken with low dose of radiation could be improved with the aid of a computer software (PhotoStyler) for digital treatrnent. Serial and standardized radiographs of molar and premolar areas were studied. A total of 57 images equivalent to the radiographs taken with reduced exposure time ( 60 and 80% of the time considered normal), digitized and treated, were submitted to the evaluation of seven exanúners which compared them with those images without treatment. lt was verified that about 80% of the images equivalem to lhe radiographs taken with 60% reduction of ordinary exposure time were considered to having quality for supporting diagnosis. As for the images taken with 80% reduction of ordinary exposure time, about 50% of them were considered suitable for the sarne purpose

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives: the administration of cyclosporin A has been associated with significant bone loss and increased bone remodeling. The present investigation was designed to evaluate the effects of cyclosporin A on alveolar bone of rats subjected to experimental periodontitis, using serum, stereometric and radiographic analysis.Methods: Twenty-four rats were divided into one of the following groups with six animals each: group I, control rats; group II, in which the animals received a cotton ligature around the lower first molars; group III, in which the rats received a cotton ligature around the lower first molars and were treated with 10 mg/(kg body weight day) of cyclosporin A; group IV, in which the rats were treated with 10 mg/(kg body weight day) of cyclosporin A. At the end of experimental period, at 30 days, animals were killed and the serum calcium and alkaline phosphatase levels were measured in all groups. The distance from the alveolar bone crest to the cemento-enamel junction was measured radiographically for each mesial surface of the lower first molars of each rat. After histological processing, the stereological parameters: volume densities of multinucleated osteoclasts (V-o), alveolar bone (V-b), marrow (V-m), and relation of eroded surface/bone surface (Es/Bs) were assessed at the mesial region of the alveolar bone.Results: Significant decreases in serum calcium were observed in those groups that received cyclosporin A therapy. No significant changes in serum alkaline phosphatase were observed. The therapy with cyclosporin A combined with the ligature placement decreased the V-b and increased the V-o, V-m and Es/Bs at the mesial surface of lower first molars. on the other hand, the radiographic data showed that cyclosporin A therapy diminished the alveolar bone loss at the mesial surface of the lower first molars.Conclusions: Therefore, within the limits of this study, we suggest that cyclosporin A at immunosuppressive levels can bring about an imbalance in the alveolar bone homeostasis in rats. However, in the presence of inflammatory stimulation, the inhibition of the immune system by cyclosporin A may decrease the initial periodontal breakdown.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Changes in mineral density in the mandibular and femoral bones (BMD) after estrogen deficiency caused by ovariectomy (OVX) and the influence of these changes on induced periodontal disease were evaluated in female rats.Methods: Forty-eight female Holtzman rats (90 days old) were randomly divided into five groups: 0: control (N = 9); 1: SHAM without induced periodontal disease (N = 11); 2: SHAM with induced disease (N = 10); 3: OVX without induced disease (N = 9); and 4: OVX with induced disease (N = 9). In groups 2 and 4, the first lower molars were tied with ligatures for 30 days 120 days after surgery. After 5 months the animals were sacrificed to measure global mineral density (BMD) and that of the sub-regions of the mandible and femur by dual energy x-ray absorptiometry (DXA). The extent of vertical bone loss was evaluated with digital radiography by measuring the distance from the bone crest to the cemento-enamel junction at the mesial of the first lower molar.Results: Results of the femur (Kruskal-Wallis test) showed a significant difference (P < 0.001) between the groups SHAM and OVX in bone density values for all regions. Comparison between the groups in relation to the BMD of the mandible, both in the sub-regions and global revealed no differences (P < 0.05). The vertical bone loss measured for the groups with induced disease was similar (P= 0.713).Conclusions: Differences between the groups were found in the bone mineral density BMD of the femur but not of the mandible. OVX had no influence on induced periodontal disease.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: The aim of this study was to evaluate the ability of Resilon (Resilon Research, LLC, North Branford, CT) and 2 types of gutta-percha to fill simulated lateral canals when using the Obtura II system (Model 823-700; Obtura Spartan, Fenton, MO). Methods: Forty-five human single-rooted teeth were selected and subjected to root canal preparation. After that, simulated lateral canals were made at 2, 5, and 8 mm from the working length (WL). The specimens were divided into 3 groups (n = 15) according to the filling material used: Obtura Flow 150 gutta-percha (Obtura flow), Odous Endo Flow gutta-percha (Odous; Odous de Deus Ind e Corn. Ltda Belo Horizonte, MG, Brazil), and Resilon pellets (Resilon). Root canals were filled using the Obtura II system with the tip inserted to 3 mm from the WL. No sealer was used for root canal obturation. Specimens were subjected to a tooth decalcification and clearing method, and filling of the lateral canals was analyzed by digital radiography and photographs. The measurement of lateral canal filling was done using Image Tool software (UTHSCSA Image Tool for Windows version 3.0, San Antonio, TX). Data were statistically analyzed with the Kruskal-Wallis test at 5% significance. Results: All materials showed an ability to penetrate into the simulated lateral canals, with a minimum percentage of 73% in all thirds of the root canal. Conclusions: It was concluded that gutta-percha and Resilon are solid core materials with a lateral canal filling ability when used with the Obtura II system. (J Endod 2012;38:676-679)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: The aim of this study was to verify, in vivo and in vitro, the prevalence of root canal bifurcation in mandibular incisors by digital radiography. Material and Methods: Four hundred teeth were analyzed for the in vivo study. Digital radiographs were taken in an orthoradial direction from the mandibular incisor and canine regions. The digital radiographs of the canine region allowed visualizing the incisors in a distoradial direction using 20 degrees deviation. All individuals agreed to participate by signing an informed consent form. The in vitro study was conducted on 200 mandibular incisors positioned on a model, simulating the mandibular dental arch. Digital radiographs were taken from the mandibular incisors in both buccolingual and mesiodistal directions. Results: The digital radiography showed presence of bifurcation in 20% of teeth evaluated in vitro in the mesiodistal direction. In the buccolingual direction, 17.5% of teeth evaluated in vivo and 15% evaluated in vitro presented bifurcation or characteristics indicating bifurcation. Conclusions: Digital radiography associated with X-ray beam distally allowed detection of a larger number of cases of bifurcated root canals or characteristics of bifurcation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: Tissue reactions to 4 different implant surfaces were evaluated in regard to the development and progression of ligature-induced peri-implantitis. Materials and Methods: In 6 male mongrel dogs, a total of 36 dental implants with different surfaces (9 titanium plasma-sprayed, 9 hydroxyapatite-coated, 9 acid-etched, and 9 commercially pure titanium) were placed 3 months after mandibular premolar extraction. After 3 months with optimal plaque control, abutment connection was performed. Forty-five days later, cotton ligatures were placed around the implants to induce peri-implantitis. At baseline and 20, 40, and 60 days after placement, the presence of plaque, peri-implant mucosal redness, bleeding on probing, probing depth, clinical attachment loss, mobility, vertical bone loss, and horizontal bone loss were assessed. Results: The results did not show significant differences among the surfaces for any parameter during the study (P > .05). All surfaces were equally susceptible to ligature-induced peri-implantitis over time (P < .001). Correlation analysis revealed a statistically significant relationship between width of keratinized tissue and vertical bone loss (r 2 = 0.81; P = .014) and between mobility and vertical bone loss (r 2 = 0.66; P = .04), both for the titanium plasma-sprayed surface. Discussion and Conclusions: The present data suggest that all surfaces were equally susceptible to experimental peri-implantitis after a 60-day period.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The reproducibility of measurements of alveolar bone loss on radiographs may be a problem on epidemiologic studies, as they are based on comparisons of the diagnosis of various examiners. The aim of the present research paper was to assess the inter- and intra-examiner reproducibility of measurements of the interproximal alveolar bone loss on non-manipulated digital radiographs and after the application of image filters. Five Oral Radiologists measured the distance between the cementoenamel junction (CEJ) to the alveolar crest or to the deepest point of the bony defect on 12 interproximal digital radiographs of molars and bicuspids of a dry human skull. The digital manipulation and the linear measurements were obtained with the Trophy Windows software (Throphy®). For each image, six different versions were created: 1) non-manipulated; 2) bright-contrast adjustment; 3) negative; 4) negative with brightness-contrast adjustment; 5) pseudo-colored; 6) pseudo-colored with brightness-contrast adjustment. In order to prevent interpretation bias because of the repetition of measurements, the examiners measured the radiographs in a random sequence. The two-way ANOVA test at 5% level of significance to compare the means of readings of the same operator with each filter indicated p<0.05 for the majority of operators, while the comparison between the mean values of operators using the same filter indicated p>0.05 for all filters. Based on the results, we concluded that linear measurements of interproximal alveolar bone loss on digital radiographs are highly reproducible among examiners. Nevertheless, the application of image filters significantly influenced the degree of intra-examiner reproducibility. Some filters even reduced the reproducibility of intra-examiner readings.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This article presents a new method to detect damage in structures based on the electromechanical impedance principle. The system follows the variations in the output voltage of piezoelectric transducers and does not compute the impedance itself. The proposed system is portable, autonomous, versatile, and could efficiently replace commercial instruments in different structural health monitoring applications. The identification of damage is performed by simply comparing the variations of root mean square voltage from response signals of piezoelectric transducers, such as lead zirconate titanate patches bonded to the structure, obtained for different frequencies of the excitation signal. The proposed system is not limited by the sampling rate of analog-to-digital converters, dispenses Fourier transform algorithms, and does not require a computer for processing, operating autonomously. A low-cost prototype based on microcontroller and digital synthesizer was built, and experiments were carried out on an aluminum structure and excellent results have been obtained. © The Author(s) 2012.