123 resultados para chromium in beer
Resumo:
This paper presents a simple, fast and sensitive method to determine chromic oxide (used as a biological marker of fish feed) in samples of fish feces by GFAAS through the direct introduction of slurries of the samples into the spectrometer's graphite tube. The standard samples of feces and of fish feed containing 0.10-1.00 mg kg(-1) of Cr2O3 were pre-frozen for I min in liquid nitrogen and then ground a cryogenic mill for 2 min, which reduced the samples' grain size to less than 60 mu m. The standard slurries were prepared by mixing 20 mg of standard samples of fish feed or feces with I mL of a solution containing 0.05% (v/v) of Triton X-100 and 0.50% (v/v) of suprapure HNO3 directly in the spectrometer's automatic sampling glass. The final concentrations of Cr2O3 present in the standard slurries were 2, 4, 8, 16 and 20 mu g L-1. After sonicating the mixture for 20s, 10 mu L of standard slurries were injected into the graphite tube, whose internal wall was lined with a metallic palladium film that acted as a permanent chemical modifier. The limits of detection (LOD) and quantification (LOQ) calculated for 20 readings of the blank of the standard slurries (2%, m/v of feces or feed devoid of minerals) were 0.81 and 2.70 mu g L-1 of Cr2O3 for the standard feces slurries, 0.84 and 2.83 mu g L-1 of Cr2O3 for the standard feed slurries. The proposed method was applied in studies of nutrient digestibility of different fish feeds and its results proved compatible with the results obtained from samples pre-mineralized by acid digestion. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
The present study was designed to analyse the average depth of the microporosity of a nickel-chromium (Ni-Cr) system alloy (Verabond II). The metal surface was subject to one of the following surface treatment: (i) Electrolytic etching in nitric acid 0.5 N at a current density of 250 mA cm(-2) ; (ii) chemical etching with CG-Etch etchant; and (iii) Sandblasting with alumina particles 50 mum. Half of the samples were polished before the surface treatments. The depth of porosity was measured through photomicrographs (500x) with a profilometer, and the data were statistically analysed using an analysis of variance (anova) followed by Tukey's test. The conclusions were (i) Differents surface treatment of the Ni-Cr system alloy lead to different depths of microporosity; (ii) the greatest depth of porosity was observed in non-polished alloy; (iii) the greatest and identical depth of microporosity was observed following electrolytic etching and chemical etching; (iv) the least and identical depth of microporosity was observed with chemical etching and sandblasting with alumina particles 50 mum, and (v) Chemical etching showed an intermediary depth.
Resumo:
Screen-printed carbon electrode (SPCE) modified with poly-L-histidine film can be successfully applied for chromium(VI) determination based on its pre-concentration. Optimum adherence and stability of the POIY-L-histidine film was obtained by direct addition of PH solution 1% (w/v) on the electrode surface, followed by heating at 80 degrees C during 5 min. Linear response range, sensitivity and limit of detection were 0. 1-150 [mu mol L-1, 4. 13 LA mu mol L` and 0.046 mu mol L-1. The repeatability of the proposed sensor, evaluated in terms of relative standard deviation, was measured as 3.2% for 10 experiments in 40 mu mol L-1 using the same electrode and 4.0% using screen-printed electrode as disposable sensor, respectively. The voltammetric sensor was applied to determination of Cr(VI) and indirect determination of Cr(III) in wastewater samples previously treated by a leather dyeing industry and the average recovery for these samples was around 97%. (C) 2006 Elsevier B.V. All rights reserved.
Resumo:
In this study undoped and Cr, Sb or Mo doped TiO(2) were synthesized by polymeric precursor method and characterized by X-ray diffraction, UV-VIS spectroscopy, infrared spectroscopy and thermogravimetry (TG). The TG curves showed a continuous mass loss assigned to the hydroxyl elimination and Cr(6+) reduction. Doped TiO(2) samples showed a higher mass loss assigned to water and gas elimination at lower temperatures. In these doped materials a decrease in the anatase-rutile phase transition temperature was observed. After calcination at 1,000 A degrees C, rutile was obtained as a single phase material without the presence of Cr(6+).
Resumo:
The comet assay technique has been considered to be more efficient in the biomonitoring of aquatic environments that the micronucleus and sister chromatid exchange techniques. The comet assay has been used to determine breaks in the DNA strands of organisms exposed to pollutants with a genotoxic potential. The comet technique was applied to CHO-K1 cells in order to evaluate the genotoxic potential of the waters of the Sapucaizinho River (Municipality of Patrocínio Paulista, State of São Paulo, Brazil), which receive tannery effluents and therefore are contaminated with chromium. The results indicated high genotoxicity of the waters collected at sites located downstream from the emission of tannery effluents, where the concentration of chromium was found to be high.
Resumo:
It is well known that the microcrack density is a fundamental parameter in hard chromium electroplating. The chemical and mechanical properties of this coating are widely dependent on its microcrack density. In this paper a simple image analysis procedure to determine microcrack density is presented in order to demonstrate it as a fundamental tool to estimate the fatigue, corrosion and wear behavior, as well as the residual stress field of a coated component. For this purpose, the image analysis procedure was carried out on two kinds of hard chromium plating - one called accelerated (high velocity of deposition and fluoride-free) and the other conventional (with fluoride). The coatings were applied on samples of AISI 4340 aeronautical steel, which is widely used in aircraft landing gear components. To characterize the practical significance of this study, the microcrack density results were related to the fatigue, wear and corrosion behavior from previous study and to the residual stress field in the coatings.
Resumo:
Aim: There is little information considering the framework association between cast clasps and attachments. The aim of this study was to evaluate the retention strength of frameworks match circumferential clasps and extra resilient attachment cast in three different alloys (cobalt-chromium, nickel-chromium titanium and commercially pure titanium), using two undercut (0.25 and 0.75 mm) and considering different period of time (0, 1/2, 1, 2, 3, 4 and 5 years). Methods: Using two metallic matrices, representing a partially edentulous mandibular right hemiarch with the first molar crown, canine root and without premolars, 60 frameworks were fabricated. Three groups (n = 20) of each metal were cast and each group was divided into two subgroups (n = 10), corresponding the molar undercut of 0.25 mm and 0.75 mm. The nylon male was positioned at the matrix and attached to the acrylic resin of the prosthetic base. The samples were subjected to an insertion and removal test under artificial saliva environment. Results: The data were analyzed and compared with ANOVAs and Tukey's test at 95% of probability. The groups cast in cobaltchromium and nickel-chromium-titanium had the highest mean retention strength (5.58 N and 6.36 N respectively) without significant difference between them, but statistically different from the group cast in commercially pure titanium, which had the lowest mean retention strength in all the periods (3.46 N). The association frameworks using nickel-chromium-titanium and cobalt-chromium could be used with 0.25 mm and 0.75 mm of undercut, but the titanium samples seems to decrease the retention strength, mainly in the 0.75 mm undercut. The circumferential clasps cast in commercially pure titanium used in 0.75 mm undercuts have a potential risk of fractures, especially after the 2nd year of use. Conclusion: This in vitro study showed that the framework association between cast clasp and an extra resilient attachment are suitable to the three metals evaluated, but strongly suggest extra care with commercially pure titanium in undercut of 0.75 mm. Clinical significance: Frameworks fabricated in Cp Ti tend to decrease in retentive strength over time and have a potential risk of fracture in less than 0.75 mm of undercut.
Resumo:
This study had as main objectiveto evaluate the influence of AHS obtained from an area under sugarcane cultivation on the dynamics of chromium species (Cr(III) and Cr(VI)). Was studied complexing capacity (CC) with the AHS of chromium species and these were characterized using UV/Vis spectrophotometry, molecular fluorescence, elemental analysis and infrared. AHS with and without fractionation showed a greater aromaticity degree and a predominance of humic acids, and the E4/E6 and E2/E4 ratios suggested aromatic rings and a greater contribution from plants, which indicates lignin structures. The highest CCs were observed for the AHS fractionated, being fraction with molecular-size < 10 kDa and 10-30 kDa showed the highest ability to complex Cr(III) and Cr(VI) ions, respectively. These results are corroborating with C/H/N and UV/Vis data, where we can conclude that the AHS without fractionation had the greatest aromaticity and a predominance of humic acids in their structure.
Resumo:
Agricultural use of tannery sludge (TS) may increase risks to soils. Thus, composting is recognized as one of the most suitable alternatives for TS recycling. Field experiments were carried out to evaluate the effects of composted tannery sludge (CTS) on chromium (Cr), cadmium (Cd), nickel (Ni), and lead (Pb) accumulation in soil after 3 years. Soil samples were collected 60 days after CTS application. After 3 years, The CTS increased Cr and Ni content, while Cd and Pb contents decreased. The third year, Cr contents showed linear increases as CTS rates were applied. The application of CTS, after 3 years, in the 2.5, 5, and 10 Mg ha(-1) increased Cr significantly (140.7%, 159.7%, and 19%, respectively) and Ni (32%, 53%, and 43.8%, respectively) contents in the soil surface layer. This means that consecutive amendments of CTS increase Cr contents in the soil and plants.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objetivou-se com este trabalho avaliar a produção fecal por meio do indicador interno, fibra em detergente neutro indigestível (FDNi), e externos, cromo complexado com ácido etilenodiaminotetracético (Cr-EDTA ) e o cloreto de itérbio (YbCl3), além de estimar o fluxo duodenal da matéria seca e os coeficientes de digestibilidades aparentes total, ruminal e pós-ruminal, de diferentes nutrientes. Foram utilizadas oito novilhas mestiças Holandês/Zebu, distribuídas em duplo quadrado latino 4 x 4. Os indicadores Cr-EDTA, YbCl3 e o FDNi não estimaram produção fecal de forma eficiente (p < 0,05), obtendo resultado de 1,64; 1,71 e 2,71 kg dia-1, respectivamente, quando comparado à coleta total de fezes, que obteve resultado de 1,39 kg dia-1. Os valores estimados de fluxo de matéria seca, tanto para a metodologia de único, quanto para de duplo indicador, podem ser considerados biologicamente aceitáveis. Contudo, o valor obtido pela associação Cr-EDTA/YbCl3, utilizada na forma de duplo indicador, foi o mais confiável, pela melhor recuperação dos indicadores externos (Cr-EDTA e YbCl3), que obtiveram médias de 89 e 85%, respectivamente, em comparação ao interno (FDNi), que obteve média 67%. Os coeficientes de digestibilidade ruminal e pós ruminal, estimados pela associação Cr-EDTA/YbCl3, foram considerados melhores, em consequência do valor de fluxo de matéria seca estimado por esta associação.