143 resultados para capacity check
Resumo:
Aim. - This study aimed to test if investigate whether the anaerobic work capacity is replenished while exercising at critical power intensity. Then, a known exercise duration, which demands high anaerobic energy contribution, was compared to intermittent exercise duration with passive and active (cycling at critical power intensity) rest periods.Methods. - Nine participants performed five sessions of testing. From the 1st to the 3rd sessions, individuals cycled continuously at different workloads (P-high, P-intermediate and P-low) in order to estimate the critical power and the anaerobic work capacity. The 4th and 5th sessions were performed in order to determine the influence of anaerobic work capacity replenishment oil exercise duration. They consisted of manipulating the resting type (passive or active) between two cycling efforts. The total exercise duration was determined by the sum of the two cycling efforts duration.Results. - The exercise duration under passive resting condition (408.0 +/- 42.0 s) was longer (p<0.05) than known exercise duration at P-intermediate (T-intermediate = 305.8 +/- 30.5 s) and than exercise duration performed under active resting conditions (T-active = 304.4 +/- 30.7s). However, there was no significant difference between T-intermediate and T-active.Conclusion. - These results demonstrated indirect evidence that the anaerobic work capacity is not replenished while exercising at critical power intensity. (C) 2008 Elsevier Masson SAS. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Este trabalho estudou a capacidade de parasitismo de Telenomus remus Nixon (Hymenoptera: Scelionidae) em ovos de Spodoptera frugiperda (Smith) (Hymenoptera: Scelionidae) nas temperaturas de 15, 20, 25, 28, 31 e 35ºC objetivando usar esse inimigo natural em programas de controle biológico em culturas onde S. frugiperda é considerada praga. O parasitismo ocorrido nas primeiras 24 h foi de 60,90; 81,65; 121,05; 117,55 e 108,55 ovos parasitados por fêmea em massas ovos com aproximadamente 150 ovos, nas temperaturas de 15, 20, 25, 28 e 31ºC. Fêmeas de T. remus causaram mais de 80% do parasitismo dos ovos nas temperaturas de 15, 20, 25, 28 e 31ºC aos 5, 27, 8, 2 e 2 dias, respectivamente. Na temperatura de 35ºC não houve parasitismo. As maiores taxas de parasitismo ocorreram nas temperaturas de 20, 25, 28 e 31ºC. A longevidade média de fêmeas de T. remus nas temperaturas compreendidas entre 15 e 31ºC variou de 15,5 a 7,7 dias. A temperatura máxima testada (35ºC) foi inadequada ao desenvolvimento de T. remus, sendo que nessa temperatura as fêmeas apresentaram longevidade bastante reduzida (1,7±0,02 dia) e não houve emergência de adultos. Todas as curvas de sobrevivência para T. remus foram do tipo I o que mostram que para todas as temperaturas há um aumento da taxa de mortalidade com o tempo.
Resumo:
O objetivo deste estudo foi analisar os efeitos do treinamento de natação na intensidade do limiar anaeróbio (LAn), determinado na piscina e no ergômetro de braço, verificando se este pode ser utilizado para avaliar os efeitos do treinamento em nadadores. Participaram do estudo sete nadadores de ambos os sexos, com nível de performance regional, que foram submetidos aos seguintes testes, antes e após oito semanas de treinamento: 1) dois tiros de 400m, um a 85% e outro a 95% do máximo, com coleta de 25mil de sangue do lóbulo da orelha no 1º, 3º e 5º minuto após cada tiro, para posterior análise do lactato sanguíneo (YSI 1500); 2) teste contínuo progressivo realizado no ergômetro de braço (UBE 2462 Cybex), com carga inicial de 33,3W e incrementos de 16,6W a cada três minutos até a exaustão voluntária, com coleta de sangue ao final de cada estágio. Um grupo controle de indivíduos não ativos (n = 9), que se manteve sedentário, realizou somente o procedimento 2 no mesmo intervalo de tempo. O LAn na natação (NLAn) e no ergômetro de braço (BLAn) foi encontrado através de interpolação linear, considerando uma concentração fixa de lactato de 4mM e 3,5mM, respectivamente. Os resultados demonstram diferença significante para o grupo treinado, entre o pré (130,4 ± 20,4W) e o pós-teste (137,7 ± 17,9W) para o BLAn. Porém, não foi encontrada diferença significante para o NLAn (1,09 ± 0,1m.s-1 e 1,13 ± 0,1m.s-1, p = 0,06). No grupo controle não foi encontrada diferença para o BLAn entre o pré (93,2 ± 11,5W) e o pós-teste (87,7 ± 7,2W). Pode-se concluir através desses dados que a determinação do LAn no ergômetro de braço é útil para detectar adaptações na capacidade aeróbia de nadadores com nível de performance regional.
Resumo:
The objectives of this study were: a) to determine, in a cross-sectional manner, the effect of aerobic training on the peak oxygen uptake, the intensity at O2peak and the anaerobic threshold (AnT) during running and cycling; and b) to verify if the transference of the training effects are dependent on the analized type of exercise or physiological index. Eleven untrained males (UN), nine endurance cyclists (EC), seven endurance runners (ER), and nine triathletes (TR) were submitted, on separate days, to incremental tests until voluntary exhaustion on a mechanical braked cycle ergometer and on a treadmill. The values of O2peak (ml.kg-1.min-1) obtained in running and cycle ergometer (ER = 68.8 ± 6.3 and 62.0 ± 5.0; EC = 60.5 ± 8.0 and 67.6 ± 7.6; TR = 64.5 ± 4.8 and 61.0 ± 4.1; UN = 43.5 ± 7.0 and 36.7 ± 5.6; respectively) were higher in the group that presented specific training in the modality. The UN group presented the lower values of O2peak, regardless of the type of exercise. This same behavior was observed for the AnT (ml.kg-1.min-1) determined in running and cycle ergometer (ER = 56.8 ± 6.9 and 44.8 ± 5.7; EC = 51.2 ± 5.2 and 57.6 ± 7.1; TR = 56.5 ± 5.1 and 49.0 ± 4.8; UN = 33.2 ± 4.2 and 22.6 ± 3.7; respectively). It can be concluded that the transference of the training effects seems to be only partial, independently of the index (O2peak, IO2peak or AnT) or exercise type (running or cycling). In relation to the indices, the specificity of training seems to be less present in the O2peak than in the IO2peak and the AnT.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Este estudo objetivou verificar a correlação entre habilidades básicas de leitura (tempo, velocidade, precisão) e compreensão de leitura de 80 escolares do 2º ao 5º ano do Ensino Público Municipal, divididos em oito grupos, conforme o ano escolar e a presença ou não de dificuldade de aprendizagem. Como procedimento, utilizou-se a leitura oral de textos correspondentes ao ano escolar, seguida de perguntas abertas para verificação da compreensão de leitura. em todos os grupos, houve diferença estatisticamente significante com correlação entre tempo de leitura e velocidade de leitura. No grupo VI, foi observada correlação entre palavras lidas incorretamente e velocidade de leitura, enquanto o grupo VII apresentou correlação entre palavras lidas incorretamente, velocidade de leitura e compreensão de leitura. Esses dados sugerem que a habilidade de compreensão de leitura requer capacidades cognitivas de alto nível, que vão além de habilidades básicas, sendo fundamental elaborar uma representação mental do conteúdo proposicional para obter o significado global da mensagem escrita.
Resumo:
An experimental investigation of air enrichment in a combustion chamber designed to incinerate aqueous residues is presented. Diesel fuel and liquefied petroleum gas (LPG) were used independently as fuels. An increase of 85% in the incineration capacity was obtained with nearly 50% O-2 in the oxidant gas, in comparison to incineration with air only. The incineration capacity continues increasing for enrichment levels above 50% O-2 , although at a lower pace. For complete oxy-flame combustion (100% O-2 ), the increase of the incineration capacity was about 110% relative to the starting conditions and about 13.5% relative to the condition with 50% O-2 . The CO concentration measured near the flame front decreases drastically with the increase of O-2 content in the oxidant gas. At the chamber exit, the CO concentration was always near zero, indicating that the chamber residence time was sufficient to complete fuel oxidation in any test setting. For diesel fuel, the NOx was entirely formed in the first region of the combustion chamber. For diesel fuel, there was some increase in the NOx concentration up to 35% of O-2 ; this increase became very sharp after that. From 60 ppm, at operation with air only, the NOx concentration raises to 200 ppm at 35% O-2 , and then to 2900 ppm at 74% O-2 . The latter corresponds to six times more NOx in terms of the ratio of mass of NO to mass of residue, compared to the situation of combustion with air only. For LPG, the NOx concentrations reached 4200 ppm at 80% O-2 , corresponding to nine times more, also in terms of the ratio of mass of NO to mass of residue, in comparison with combustion with air only. Results of different techniques used to control the NOx emission during air enrichment are discussed: (a) variation of the recirculated zone intensity, (b) increase of the spray Sauter mean diameter, (c) fuel staging, (d) oxidizer staging, and (e) ammonia injection. The present paper shows that NOx emission may be controlled without damage of the increase of incineration capacity by the enrichment and with low emission of partial oxidation pollutants such as CO.