45 resultados para bending test


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present study evaluated the use of semicircular bending test (SCB) as an alternative to conventional bending test to examine the effect of thermal shock. Still, studies the behavior of fracture surfaces generated by monofractal behavior analysis, which allows us to evaluate the contributions of the microstructure and the mechanical context in forming reliefs during the crack propagation. The fractal analysis is made from elevation maps obtained by reconstruction method by extension of the focus stacks of digital images acquired in microscope. The specimens used were samples semicircular pressed TiO2 (rutile) with and without heat shock, prepared for testing mode I loading. Were also produced, specimens in the form of bars for Weibull statistical analysis. From the three-point bending test, we found the variation of fracture toughness between the samples after the heat shock and natural condition. The SCB test was feasible for the analysis of thermal shock resistance. The results showed that the value of the fracture toughness decreases as the heat shock treatment

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The study of physical and mechanical properties of wood is essential for its structural use and it is of great importance to the construction industry. Thus, this study aimed to determine the physical and mechanical properties of the wood Amaru - a hybrid of Eucalyptus, developed by Plantar Projects and Forest Products Ltda. In order to determine the properties of Amaru, round samples were used, which were provided to the Laboratory of Wood and Wooden Structures of the School of Engineering of São Carlos, University of São Paulo - LaMEM / EESC / USP. For the characterization of the physical properties, the apparent specific gravity and moisture content of the samples were determined. To the mechanical characterization, the following properties were evaluated: strength and stiffness in compression, strength and stiffness in bending, shear and tension. The procedures of the tests performed in this study were done according to the recommendations of the Brazilian Wood Standard ABNT NBR 7190:1997. The specimen used were confectioned in actual dimensions, according to as those used in the construction system proposed by Plantar. The results obtained from the tests performed showed that the mechanical properties approached the values proposed by the Wood Standard NBR 7190. The visual grading was important to provide a primary idea about the failure modes to be obtained from the tests performed. The bending test showed the modulus of elasticity (MOE) and Modulus of Rupture (MOR), which resulted in 15822 MPa and 101,7 MPa, respectively. The compression test resulted in values Ec0,m and fc0, 15698 MPa and 50,7 MPa. The tensile strength (ft0) of this hybrid was calculated and its value obtained was 60,8 MPa. The shear strength (fv0) was 8,2 MPa. The results obtained from the tests are the basis for engineers and architects to design structures using wood species Amaru

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aimed to investigate the influence of storage time (0, 48 hours) of Pinus elliottii pieces and the tests to obtaining modulus of elasticity (static bending and transversal vibration) in glued laminated timber beams, produced with resorcinol based adhesive and 0.8 MPa compaction pressure. After pieces were properly prepared, part of them was used in immediate three manufacturing glulam beams, tested after adhesive cure, and part stored for 48 hours under a roof with a temperature of 25°C and relative humidity of 60% for subsequent manufacturing and testing three other glulam beams. Results of analysis of variance (ANOVA) revealed that the storage period was significant influence in modulus of elasticity obtained in static bending test (8% reduction from 0 to 48 hours). This not occurred with modulus of elasticity obtained by transversal vibration test (no significant influence). ANOVA results showed equivalence of means in both test procedures. New researches ire needed to better understand the investigated phenomenon, using new wood species, other storage conditions and a great number of samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present study was to assess the spectral behavior of the erector spinae muscle during isometric contractions performed before and after a dynamic manual load-lifting test carried out by the trunk in order to determine the capacity of muscle to perform this task. Nine healthy female students participated in the experiment. Their average age, height, and body mass (± SD) were 20 ± 1 years, 1.6 ± 0.03 m, and 53 ± 4 kg, respectively. The development of muscle fatigue was assessed by spectral analysis (median frequency) and root mean square with time. The test consisted of repeated bending movements from the trunk, starting from a 45º angle of flexion, with the application of approximately 15, 25 and 50% of maximum individual load, to the stand up position. The protocol used proved to be more reliable with loads exceeding 50% of the maximum for the identification of muscle fatigue by electromyography as a function of time. Most of the volunteers showed an increase in root mean square versus time on both the right (N = 7) and the left (N = 6) side, indicating a tendency to become fatigued. With respect to the changes in median frequency of the electromyographic signal, the loads used in this study had no significant effect on either the right or the left side of the erector spinae muscle at this frequency, suggesting that a higher amount and percentage of loads would produce more substantial results in the study of isotonic contractions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cold-formed steel shapes have been widely employed in steel construction, where they frequently offer a lower cost solution than do traditional laminated shapes. A classic application of cold-formed steel shapes is purlins in the roof panel of industrial buildings, connected to the roof panel by means of screws. The combined effect of these two elements has been the subject of investigations in some countries. Design criteria were included in the AISI Code in 1991 and 1996. This paper presents and discusses the results obtained from bending tests carried out on shapes commonly used in Brazil, i.e., the channel and the simple lipped channel, Tests were carried out on double shapes with 4.5 and 6.0 meter spans, which were subjected to concentrated loads and braced against each other on the supports and at intermediary points in three different load situations. The panel shape was also analyzed experimentally, simulating the action of wind by means of a vacuum box designed specifically for this purpose. The test results were then compared to those obtained through the theoretical analysis, enabling us to extract important information upon which to base proposed design criteria for the new Brazilian code.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since Ranzini suggested supplementing the SPT test with measurement of the torque required to turn the split spoon sampler after driving, many Brazilian engineers have been using this in the design of pile foundations. This paper presents a study of the rod length influence in the torque measurement. A theoretical study of material resistance considering torsion and bending in a thin wall tubular steel shaft was performed. It makes possible to conclude that the shearing tension caused by the proper weight represents less than 1% of the shearing tension caused by the turning moment. In addition, an experimental study was done with electric torquemeters fixed in a horizontal rod system. The tests were being carried out to analyze rods of one meter to twenty meters in length and the measurements were collected at the ends of each rod length verifying the efficiency data. As a result, it is possible to verify that the torque difference through rod length is lower than minimum scales of mechanical torquemeters that are used on practical engineering. Also a fact to be considered is a big torque loss for values under 20 N.m of applied torque. This way, the SPT-T is not adequate to low consistency soil. Copyright ASCE 2007.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The influence of soil drill rod length on the N value in the SPT-T test has been studied extensively by Mello (1971), Schmertmann & Palacios (1979), Odebrecht et al. (2002) and Cavalcante (2002). This paper presents an analysis of the Standard Penetration Test supplemented with torque measurement (SPT-T). A theoretical study of the resistance of the rod material to torsion and bending indicated that the shear stress caused by the rod self-weight represents less than 1% of that caused by the torsional moment. An experimental study with electric torquemeters attached to a horizontal rod system, as well as two field tests in the vertical direction, were also carried out to compare and substantiate the results. The purpose of these tests was to analyze changes along the length of the rod in response to successive increments at 1-meter intervals. Torque measurements were taken at each increment of the length to ascertain the accuracy of the theoretical data. The difference between the applied torque and the measured torque at the end of rod system was lower than the minimum scale of mechanical torquemeters used in practice.