137 resultados para apical leakage
Tissue reaction to Endométhasone sealer in root canal fillings short of or beyond the apical foramen
Resumo:
Objective: This study evaluated the response of periapical tissues to the endodontic sealer Endomethasone in root canal fillings short of or beyond the apical foramen. Material and Methods: Twenty root canals of premolars and incisors of 2 mongrel dogs were used. After coronal access and pulp extirpation, the canals were instrumented up to a size 55 K-file and the apical cemental barrier was penetrated with a size 15 K-file to obtain a main apical foramen, which was widened to a size 25 K-file. The canals were irrigated with saline at each change of file. The root canals were obturated either short of or beyond the apical foramen by the lateral condensation of gutta-percha and Endomethasone, originating 2 experimental groups: G1: Endomethasone/short of the apical foramen; G2: Endomethasone/beyond the apical foramen. The animals were killed by anesthetic overdose 90 days after endodontic treatment. The individual roots were obtained and serial histological sections were prepared for histomorphological analysis (H&E and Brown & Brenn techniques) under light microscopy. The following parameters were examined: closure of the apical foramen of the main root canal and apical opening of accessory canals, apical cementum resorption, intensity of the inflammatory infiltrate, presence of giant cells and thickness and organization of the apical periodontal ligament. Each parameter was scored 1 to 4, 1 being the best result and 4 the worst. Data were analyzed statistically by the Wilcoxon nonparametric tests (p=0.05). Results: Comparing the 2 groups, the best result (p<0.05) was obtained with root canal filling with Endomethasone short of the apical foramen but a chronic inflammatory infiltrate was present in all specimens. Conclusions: Limiting the filling material to the root canal space apically is important to determine the best treatment outcome when Endomethasone is used as sealer.
Resumo:
Objective. The aim of this study was to evaluate the influence of apical foramen widening on the healing of chronic periapical lesions in dogs' teeth after root canal filling with Sealer 26 or Endomethasone.Study design. Forty root canals of dogs' teeth were used. After pulp extirpation, the canals were exposed to the oral cavity for 180 days for induction of periapical lesions, and then instrumented up to a size 55 K-file at the apical cemental barrier. In 20 roots, the cemental canal was penetrated and widened up to a size 25 K-file; in the other 20 roots, the cemental canal was preserved (no apical foramen widening). All canals received a calcium hydroxide intracanal dressing for 21 days and were filled with gutta-percha and 1 of the 2 sealers: group 1: Sealer 26/apical foramen widening; group 2: Sealer 26/no apical foramen widening; group 3: Endomethasone/apical foramen widening; group 4: Endomethasone/no apical foramen widening. The animals were killed after 180 days, and serial histologic sections from the roots were prepared for histomorphologic analysis. Scores were assigned according to preestablished histomorphologic parameters and analyzed statistically by Kruskal-Wallis and Mann-Whitney U tests.Results. Regarding new cementum formation, repair of cementum and bone resorption areas, presence of microorganisms, inflammatory cell infiltrate and periodontal ligament conditions, significantly better periapical healing was obtained when foramen widening was done and Sealer 26 was used.Conclusion. Apical foramen widening and calcium hydroxide-containing sealer were more favorable to the healing of chronic periapical lesions. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;109:932-940)
Resumo:
This study evaluated the response of periapical tissues to the endodontic sealer EndoREZ in root canal fillings short of or beyond the apical foramenlike communication. Twenty root canals of premolars and incisors of 2 mongrel dogs were used. After coronal access and pulp extirpation, the canals were instrumented up to a size 55 K-file and the apical cemental barrier was penetrated with a size 15 K-file to create an apical foramenlike communication, which was widened to a size 25 K-file. The canals were irrigated with saline at each change of file. The root canals were obturated either short of or beyond the apical foramenlike opening by the lateral condensation of gutta-percha and EndoREZ, originating 2 experimental groups: G1, EndoREZ/short of the apical foramenlike opening, and G2, EndoREZ/beyond the apical foramenlike opening. The animals were killed by anesthetic overdose 90 days after endodontic treatment. The individual roots were obtained and serial histological sections were prepared for histomorphological analysis (H&E and Brown and Brenn techniques) under light microscopy. The following parameters were examined: closure of the apical foramenlike communication and apical opening of accessory canals, apical cementum resorptions, intensity of the inflammatory infiltrate, presence of giant cells, and thickness and organization of the apical periodontal ligament. Each parameter was scored 1 to 4, 1 being the best result and 4 the worst. Data were analyzed statistically by the Wilcoxon nonparametric tests (P = .05). Comparing the 2 groups, the best result (P = .05) was obtained with root canal filling with EndoREZ short of the apical foramenlike opening. In conclusion, limiting the filling material to the root canal space apically was important to determine the best treatment outcome when EndoREZ was used as the sealer. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: e94-e99)
Resumo:
The aim of this study was to evaluate the periapical healing after the use of membrane, bone graft, and mineral trioxide aggregate (MTA) in apical surgery of dogs' teeth. Apical lesions were induced in 48 roots of 6 dogs after coronal access and pulpal removal. Apical surgery consisted of osteotomy with trephine bur for the standardization of the critical surgical cavities, followed by apicoectomy, curettage, preparation of the root-end cavities with the aid of the ultrasonic device, and retrofilling with MTA. The surgical sites were divided into: group 1-filled with blood; group 2-filled with blood and recovered with membrane; group 3-filled with bone graft; and group 4-filled with bone graft and recovered with membrane. The results showed that the inflammatory infiltrate, the periapical healing process, and the behavior of MTA was the same in all groups, including the mineralization stimulation. It was concluded that the use of membranes and bone graft materials isolated or associated in apical surgery did not alter the periapical healing process after the root-end filling with MTA. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: 309-314)
Resumo:
Purpose: To evaluate the accuracy of Image Tool Software 3.0 (ITS 3.0) to detect marginal microleakage using the stereomicroscope as the validation criterion and ITS 3.0 as the tool under study.Materials and Methods: Class V cavities were prepared at the cementoenamel junction of 61 bovine incisors, and 53 halves of them were used. Using the stereomicroscope, microleakage was classified dichotomously: presence or absence. Next, ITS 3.0 was used to obtain measurements of the microleakage, so that 0.75 was taken as the cut-off point, and values equal to or greater than 0.75 indicated its presence, while values between 0.00 and 0.75 indicated its absence. Sensitivity and specificity were calculated by point and given as 95% confidence interval (95% CI).Results: The accuracy of the ITS 3.0 was verified with a sensitivity of 0.95 (95% CI: 0.89 to 1.00) and a specificity of 0.92 (95% CI: 0.84 to 0.99).Conclusion: Digital diagnosis of marginal microleakage using ITS 3.0 was sensitive and specific.
Resumo:
Objective. The objective of this study was to evaluate the sealing ability of AH Plus, Epiphany, Acroseal, Endofill, and Polifil after active lateral condensation technique, by using a bacterial test, during 64 days.Study design. One hundred bovine incisors were cleaned and shaped; then they were filled with the endodontic sealers and adapted into a microcentrifuge tube. The setup root/microcentrifuge tube was added to glass flasks containing Brain Heart Infusion broth. A culture of Enterococcus faecalis was inserted into the upper chamber of each assembly. Daily leakage was evaluated through the broth turbidity.Results. The results were submitted to statistical analysis (Kaplan-Meier method, Kruskal-Wallis and Dunn tests).Conclusions. AH Plus and Endofill had the worst sealing ability when compared with Polifil, which showed the least leakage. Acroseal and Epiphany showed a tendency toward having an intermediate behavior; however, there was no significant difference among Acroseal, Epiphany, and the other sealers. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: e56-e60)
Resumo:
The aim of this ex vivo study was to evaluate bacterial penetration after filling root canals using 3 different techniques. Three experimental groups of 25 teeth each, obturated with lateral-warm-vertical condensation of gutta-percha, Microseal technique and EndoREZ (R) system, respectively, were tested in a split chamber model system using Enterococcus faecalis and monitored for 180 days to determine bacterial penetration. A statistical analysis was performed using the Kaplan-Meier method. Median survival time was 25 days for Microseal system, 41 for lateral-warm-vertical condensation and 81 for EndoREZ (R). Significant differences were demonstrated between Microseal and EndoREZ (R) (p<0.001) and between Microseal and lateral-warm-vertical condensation technique (p<0.05). No statistically significant differences were observed between EndoREZ (R) and lateral-warm-vertical condensation. After 180 days of assessment, 20% of the EndoREZ (R) samples resisted bacterial penetration and furthermore, the EndoREZ (R) system has the potential to be a filler system compatible with other currently used systems.
Resumo:
Objective. The goal of this study was to check whether leakage results of the same specimens measured by 2 different leakage models are similar.Study design. Canine root canals were prepared and filled with cold gutta-percha cones and 1 of 4 sealers (20 canals for each sealer). The 80 specimens were first connected to a fluid transport model where air-bubble movement was measured. The same specimens were later connected to a glucose penetration model where the concentration of glucose was measured. In both models, a headspace pressure of 30 kPa was used to accelerate leakage.Results. In both models, 4 sealers ranked the same regarding the leakage they allowed, and a significant correlation between the results of the 2 models was confined (Spearman test coefficient = 0.65; P = .000001).Conclusion. Under the conditions of this study, leakage results of 80 specimens recorded in the fluid transport model and glucose penetration model were similar.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to evaluate the apical sealing of dentinal tubules after root-end surface cutting by using Er:YAG and Nd:YAG lasers. After root-canal instrumentation and filling, apices of 50 extracted maxillary canine human teeth were resected by Er: YAG with 400 mJ, 10 Hz, for 30 sec. The samples were randomly assigned to five groups (n = 10): (GI) treated without root-end cavity, but with Nd: YAG (1.0W, 10 Hz, 20 sec) for dentinal tubules sealing; (GII) treated with root-end cavity without the use of Nd: YAG; (GIII) treated with root-end cavity and Nd: YAG application; (GIV) treated with root-end cavity made by Er: YAG with no focus and without Nd: YAG application; and (GV) treated without root-end cavity and without Nd: YAG application. The root-end cavities were performed by using Er: YAG at 300 mJ, 10 Hz, for 20 sec. Subsequently, all teeth were waterproofed and immersed in 2% methylene blue for 48 h in a vacuum environment. The samples were longitudinally sectioned, and microleakage was measured. ANOVA and the Fisher LSD test showed that GIV was less susceptible to microleakage than were the other groups (p < 0.05). Interestingly, the use of the Er: YAG with no focus showed superior dentinal tubule sealing in comparison with the other groups, even with or without root-end cavity and Nd: YAG application.
Resumo:
The purpose of the present study was to evaluate in vitro the degree of marginal leakage in Class V cavities involving the cementoenamel junction. Cavities were 4 rum wide and 2 mm deep. The specimens received dentin pretreatment (37% phosphoric acid) followed by the Single Bond (3M) adhesive system application. The 40 specimens were then divided into four groups: Group I (control); Group 2 (Nd:YAG laser at 120 mJ/pulse, frequency of 10 Hz, power of 1.2 W); Group 3 (Nd:YAG laser at 140 mJ/pulse, frequency of 10 Hz, power of 1.4 W); Group 4 (Nd:YAG laser at 160 mJ/pulse, frequency of 10 Hz, power of 1.6 W). The cavities were restored with Z100 composite resin (3M) and light cured at 300-600 mW/cm(2) light intensity. Specimens were thermocycled to 500 cycles from 2-50 degrees C. After that, they were dried and sealed with nail varnish, respecting 1 mm around the restorations, and immersed in 0.5% methylene blue solution for 4 h. After this period, the teeth were rinsed, dried, sectioned, and analyzed in a stereoscopic loupe. The highest leakage scores were considered for each specimen. The results were statistically analyzed by the analysis of variance (ANOVA) Kruskal-Wallis test to the 5% level. For both the enamel and cementum, there was a decrease in marginal leakage with the application of laser energy; no significant differences were observed for Groups 2, 3, and 4. The results also showed a smaller tendency to marginal leakage on the cementum than on the enamel.
Resumo:
This article compares the efficiency of induced polarization (IP) and resistivity in characterizing a contamination plume due to landfill leakage in a typical tropical environment. The resistivity survey revealed denser electrical current flow that induced lower resistivity values due to the high ionic content. The increased ionic concentration diminished the distance of the ionic charges close to the membrane, causing a decrease in the IP phenomena. In addition, the self-potential (SP) method was used to characterize the preferential flow direction of the area. The SP method proved to be effective at determining the flow direction; it is also fast and economical. In this study, the resistivity results were better correlated with the presence of contamination (lower resistivity) than the IP (lower chargeability) data.