136 resultados para Water Distribution Networks Infrastructure Health
Resumo:
Since the 1980s, huge efforts have been made to utilise renewable energy sources to generate electric power. One of the interesting issues about embedded generators is the question of optimal placement and sizing of the embedded generators. This paper reports an investigation of impact of the integration of embedded generators on the overall performances of the distribution networks in the steady state, using theorem of superposition. Set of distribution system indices is proposed to observe performances of the distribution networks with embedded generators. Results obtained from the case study using IEEE test network are presented and discussed.
Resumo:
Known as one of the ten most important advances on Public Health in the 20th century, fluoridation of public water supply is a measure of wide population coverage, which is effective on caries control. The city of Araçatuba, in the Northwest region of the São Paulo state, Brazil, started public water supply fluoridation in 1972 and, based on the average annual highest temperature, has kept the fluoride concentration between 0.6 to 0.8 mgF/L. The purpose of this study was to analyze monthly the fluoride concentration in public water supply in the city of Araçatuba during 72 months. Water samples were collected monthly on weekdays, directly from the water distribution network, on pre-established locations and analyzed in duplicate between November 2004 and October 2010 at the Research Laboratory of the Nucleus for Public Health (NEPESCO) of the Public Health Graduate Program from Araçatuba Dental School/UNESP, Brazil, using an fluoride-specific electrode connected to an ion analyzer. From the total of samples (n=591), 67.2% (n=397) presented fluoride concentration between 0.6 and 0.8 mgF/L; 20.6% (n=122) below 0.6 mgF/L; 11.5% (n=68) between 0.8 and 1.2 mgF/L and 0.7% (n=4) above 1.2 mgF/L. Most samples showed fluoride levels within the recommended parameters. Minimal variation was observed among the analyzed collection locations, showing that the city has been able to control the fluoride levels in the public water supply and reinforcing the importance of surveillance and constant monitoring to assure the quality of the water delivered to the population.
Resumo:
Fluoride levels in the public water supplies of 40 Brazilian cities were analyzed and classified on the basis of risk/benefit balance. Samples were collected monthly over a seven-year period from three sites for each water supply source. The samples were analyzed in duplicate in the laboratory of the Center for Research in Public Health - UNESP using an ion analyzer coupled to a fluoride-specific electrode. A total of 19,533 samples were analyzed, of which 18,847 were artificially fluoridated and 686 were not artificially fluoridated. In samples from cities performing water fluoridation, 51.57% (n=9,720) had fluoride levels in the range of 0.55 to 0.84 mg F/L; 30.53% (n=5,754) were below 0.55 mg F/L and 17.90% (n=3,373) were above 0.84 mg F/L (maximum concentration=6.96 mg F/L). Most of the cities performing fluoridation that had a majority of samples with fluoride levels above the recommended parameter had deep wells and more than one source of water supply. There was some variability in the fluoride levels of samples from the same site and between collection sites in the same city. The majority of samples from cities performing fluoridation had fluoride levels within the range that provides the best combination of risks and benefits, minimizing the risk of dental fluorosis while preventing dental caries. The conduction of studies about water distribution systems is suggested in cities with high natural fluoride concentrations in order to optimize the use of natural fluoride for fluoridation costs and avoid the risk of dental fluorosis.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this paper, a multi-objective approach for observing the performance of distribution systems with embedded generators in the steady state, based on heuristic and power system analysis, is proposed. The proposed hybrid performance index describes the quality of the operating state in each considered distribution network configuration. In order to represent the system state, the loss allocation in the distribution systems, based on the Z-bus loss allocation method and compensation-based power flow algorithm, is determined. Also, an investigation of the impact of the integration of embedded generators on the overall performance of the distribution systems in the steady state, is performed. Results obtained from several case studies are presented and discussed. Copyright (C) 2004 John Wiley Sons, Ltd.
Resumo:
Optimised placement of control and protective devices in distribution networks allows for a better operation and improvement of the reliability indices of the system. Control devices (used to reconfigure the feeders) are placed in distribution networks to obtain an optimal operation strategy to facilitate power supply restoration in the case of a contingency. Protective devices (used to isolate faults) are placed in distribution systems to improve the reliability and continuity of the power supply, significantly reducing the impacts that a fault can have in terms of customer outages, and the time needed for fault location and system restoration. This paper presents a novel technique to optimally place both control and protective devices in the same optimisation process on radial distribution feeders. The problem is modelled through mixed integer non-linear programming (MINLP) with real and binary variables. The reactive tabu search algorithm (RTS) is proposed to solve this problem. Results and optimised strategies for placing control and protective devices considering a practical feeder are presented. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In most of the cases, the systems of water distribution from groundwater wells use electrical submersible pumps. All electrical energy is applied to the pumps; however, other components (pipes, valves, etc.) of these systems are also responsible by the higher or lower consumption of electric energy. The supervisors and operators of the systems should thus have knowledge of the global energetic behavior of the process in order to administrate it properly. This work suggests a 'Global Energetic Efficiency Indicator' for groundwater wells by using mathematical equations and neural networks. Simulation results will be presented in order to demonstrate the validity of the proposed approach.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In this paper, it is presented a methodology for three-phase distribution transformer modeling, considering several types of transformer configuration, to be used in algorithms of power flow in three-phase radial distribution networks. The paper provides a detailed discussion about the models and the results from an implementation of the power flow algorithm. The results, taken from three different networks, are presented for several transformer configurations and for voltage regulators as well.
Resumo:
Objectives: To investigate the relationships between socio-demographic factors, infant feeding habits, oral hygiene and the prevalence and patterns of caries in Brazilian 3-4-year-olds. Methods: Systematic random sampling was used to select children enrolled in municipal nurseries in Araraquara, Brazil, in 1998. Clinical examinations were carried out by one examiner using dmft and dmfs indices and WHO criteria. Questionnaires for information related to the socio-demographic background, oral hygiene and dietary history of the children were completed by their mothers. Results: Caries was seen in 46% of the children; 17% of them had the more extensive pattern involving molars and incisors. Social class, mother's education, and age at which breast-feeding terminated showed statistically significant associations with caries. Feeding bottles with added sugars were still being given to 80% of the children. When the significant variables were taken into account only age at which breast-feeding terminated showed a significant relationship to the pattern of disease. Children who were never breast-fed or were breast-fed beyond the age of 24 months had a higher prevalence of the more extensive pattern of caries. Conclusions: The association between the length of time a mother breast-feeds and extensive caries should be a consideration in any local infant feeding policies or health promotion strategies. The duration for appropriate breast- or bottle-feeding should be emphasised.
Resumo:
Since the 80s huge efforts have been made to utilize renewable energy sources to generate electric power. An important issue about using renewable energy sources is a Distribution Management System (DMS) in presence of dispersed generators. This paper reports some aspects of integration of the dispersed generators in the DMS. Besides, an investigation of impact of the dispersed generators on the overall performances of the distribution systems in steady state is performed. In order to observe losses in the distribution networks with dispersed generators, several loss allocation methods are applied. Results obtained from case study using IEEE test network, are presented and discussed. © 2003 IEEE.
Resumo:
Three-phase three-wire power flow algorithms, as any tool for power systems analysis, require reliable impedances and models in order to obtain accurate results. Kron's reduction procedure, which embeds neutral wire influence into phase wires, has shown good results when three-phase three-wire power flow algorithms based on current summation method were used. However, Kron's reduction can harm reliabilities of some algorithms whose iterative processes need loss calculation (power summation method). In this work, three three-phase three-wire power flow algorithms based on power summation method, will be compared with a three-phase four-wire approach based on backward-forward technique and current summation. Two four-wire unbalanced medium-voltage distribution networks will be analyzed and results will be presented and discussed. © 2004 IEEE.
Resumo:
This paper presents a new methodology to evaluate in a predictive way the reliability of distribution systems, considering the impact of automatic recloser switches. The developed algorithm is based on state enumeration techniques with Markovian models and on the minimal cut set theory. Some computational aspects related with the implementation of the proposed algorithm in typical distribution networks are also discussed. The description of the proposed approach is carried out using a sample test system. The results obtained with a typical configuration of a Brazilian system (EDP Bandeirante Energia S.A.) are presented and discussed.