113 resultados para Valve
Resumo:
Newly discovered benthic fossils and specimens illustrated in the paleontological literature indicate that drilling predators (or parasites) were present in the Permian. New field data from southern Brazil document the first drill holes ever reported for Permian bivalve mollusks. In addition, a literature review revealed drill holes in shells of articulate brachiopods from Russia, Greece, and West Texas. Holes range in size from 0.1 to 5.8 mm and are typically round, cylindrical, singular penetrations perpendicular to the valve surface. Incomplete, healed, and multiple holes are absent. Drilling frequency, a proxy for predation intensity, is very low: less than 1 percent (this estimate may be seriously affected by taphonomic and monographic biases). Literature data suggest that frequency of drilled specimens varied significantly among higher brachiopod taxa. The geography and stratigraphy of drilled specimens indicate that drilling organisms were worldwide in their occurrence and continuously present in marine ecosystems throughout the Permian. This report is consistent with other recent studies indicating that although drillers were continuously present throughout the Phanerozoic, drilling intensity was lower in the Late Paleozoic and early Mesozoic.
Resumo:
An automatic Procedure with a high current-density anodic electrodissolution unit (HDAE) is proposed for the determination of aluminium, copper and zinc in non-ferroalloys by flame atonic absorption spectrometry, based on the direct solid analysis. It consists of solenoid valve-based commutation in a flow-injection system for on-line sample electro-dissolution and calibration with one multi-element standard, an electrolytic cell equipped with two electrodes (a silver needle acts as cathode, and sample as anode), and an intelligent unit. The latter is assembled in a PC-compatible microcomputer for instrument control, and far data acquisition and processing. General management of the process is achieved by use of software written in Pascal. Electrolyte compositions, flow rates, commutation times, applied current and electrolysis time mere investigated. A 0.5 mol l(-1) HNO3 solution was elected as electrolyte and 300 A/cm(2) as the continuous current pulse. The performance of the proposed system was evaluated by analysing aluminium in Al-allay samples, and copper/zinc in brass and bronze samples, respectively. The system handles about 50 samples per hour. Results are precise (R.S.D < 2%) and in agreement with those obtained by ICP-AES and spectrophotometry at a 95% confidence level.
Resumo:
A microactuator made from poly(vinylidene fluoride) (PVDF), a piezoelectric polymer, was fabricated to control the gas flow rate through a glass micronozzle. The actuator was formed by gluing together two PVDF sheets with opposite polarization directions. The sheets were covered with thin conducting films on one side, that were then used as electrodes to apply an electric field to move the valve. The actuator has a rectangular shape, 3 mm x 6 mm. The device was incorporated with a micronozzle fabricated by a powder blasting technique. Upon applying a DC voltage across the actuator electrodes, one sheet expands while the other contracts, generating an opening motion. A voltage of +300 V DC was used to open the device by moving the actuator 30 mu m, and a voltage of -200 V DC was used to close the device by moving the actuator 20 mu m lower than the relaxed position. Flow measurements were performed in a low-pressure vacuum system, maintaining the microvalve inlet pressure constant at 266 Pa. Tests carried out with the actuator in the open position and with a pressure ratio (inlet pressure divided by outlet pressure) of 0.5, indicated a flow rate of 0.36 sccm. In the closed position, and with a pressure ratio of 0.2, a flow rate of 0.32 sccm was measured.
Resumo:
Study of the epithelial morphology of a stingless bee ileum from the pyloric valve to the last portion of high absorptive cells shows that although the bee ileum is an anatomically undifferentiated tube, four types of epithelial cells along the tube (in addition to the valve cells) indicate physiological differentiation. The anterior end seems to be less active in reabsorption, while the posterior region contains cells with typical morphology of an ion pump and permits conclusions about the mechanisms of absorption in the posterior end of the intestine. (C) 1994 Wiley-Liss, Inc.
Resumo:
The changes of arterial pressure promoted by bolus injection of 50 mg phenylephrine (PHE) were studied in 20 atropinized patients (5 normal subjects, 13 patients with mitral valve disease, 1 patient with essential arterial hypertension and 1 patient with hypertrophic cardiomyopathy) submitted to routine catheterism. Patients with aortic valve disease, left ventricular outflow tract obstruction and intracardiac shunt were excluded from the study. All patients were in sinus rhythm, without heart failure. Arterial pressure started to increase at 14.8 +/- 5.4 s (range, 5.6 to 27 s; mean +/- SD) after PHE. There was an increase of 37.8 +/- 16.7 mmHg (range, 12.5 to 70 mmHg) in systolic pressure and of 26.6 +/- 11.1 mmHg (range, 7.5 to 42.5 mmHg) in diastolic pressure. Peak hypertension was attained at 36.6 +/- 16.4 s (range, 10.8 to 64.9 s) and hypertension continued for 176 +/- 92 s (range, 11 to 365 s). Heart rate was 114 +/- 21 bpm before PHE and 111 +/- 21 bpm (P<0.05) after PHE. There were no adverse events associated with intravenous PHE injection in any patient, in accordance with the general view that bolus injection of PHE is a safe and practical maneuver to promote arterial hypertension.
Resumo:
Ultrastructure of the anterior end of the midgut of three Neotropical stingless bees, including an obligate necrophagous species Trigona hypogea, suggests that this midgut region has no role in nutrient absorption because its lumen is reduced by a thick cuticle that lines the outer epithelium of the cardiac valve. A possible involvement of this midgut region in the production of the peritrophic membrane compounds is discussed.
Resumo:
The coronary sinus was investigated in 34 normal adult dogs, in order to verify its formation, tributaries, length and the valves, as well as the relationship of the venous walls to the epicardium and to the myocardium. The valve of the coronary sinus was observed in only 4 cases (1.7 %). In 30 cases (98.3 %) the ostium of the coronary sinus was lacking a valve. The valve of Vieussens double, was found at the level of the transition between the great cardiac vein and the coronary sinus, as well as others parietal venous valves. A comparison with the human pattern was made, particularly regarding the action of the valve of the coronary sinus and the formation of the sinus.
Resumo:
Ti-Mo alloys from 4 to 20 Mo wt.% were arc-melted. Their compositions and surfaces were analyzed by EDX, XRF and SEM. The Mo mapping shows a homogeneous distribution for all alloys. The XRD analysis showed that the crystal structure of the alloys is sensitive to the Mo concentration; a mixture of the hexagonal alpha' and orthorhombic alpha '' phases was observed for the Ti-4Mo alloy, and the alpha '' phase is observed almost exclusively when the concentration of Mo added to the Ti reaches 6%. A significant retention of the beta phase is observed for the alloy containing 10% Mo, while at higher Mo concentrations (15% and 20%), retention of phase beta is only verified. Preliminary electrochemical studies have indicated a valve-metal behavior and good corrosion resistance in aerated Ringer solution for all alloys. (c) 2006 Published by Elsevier B.V.
Resumo:
Over 14,000 specimens-5,204 brachiopods, 9,137 bivalves, and 178 gastropods-acquired from 30 collecting stations (0 to 45 m depth) in the Ubatuba and Picinguaba bays, southern Brazil, were compared for drilling frequencies. Beveled (countersunk) circular-to-subcircular borings (Oichnus-like drill holes) were found in diverse bivalves but also in the rhynchonelliform brachiopod Bouchardia rosea-a small, semi-infaunal to epifaunal, free-lying species that dominates the brachiopod fauna of the southern Brazilian shelf. Drill holes in bivalve mollusks and brachiopods are comparable in their morphology, average diameter, and diameter range, indicating attacks by a single type of drilling organism. Drill holes in brachiopods were rare (0.4%) and found only at five sampling sites. Drillings in bivalves were over 10 times as frequent as in brachiopods, but the average drilling frequency was still low (5.6%) compared to typical boring frequencies of Cenozoic mollusks. Some common bivalve species, however, were drilled at frequencies up to 50 times higher than those observed for shells of B. rosea from the same samples. Due to scarcity of drilled brachiopods, it is not possible to evaluate if the driller displayed a nonrandom (stereotyped) site, size, or valve preference. Drilled brachiopods may record (1) naticid or muricid predation, (2) predation by other drillers, (3) parasitic drillings, and (4) mistaken or opportunistic attacks. Low drilling frequency in brachiopods is consistent with recent reports on ancient and modern examples. The scarcity of drilling in brachiopods, coupled with much higher drilling frequencies observed in sympatric bivalves, suggests that drilling in brachiopods may have been due to facultative or erroneous attacks. The drilling frequencies observed here for the brachiopod-bivalve assemblages are remarkably similar to those reported for Permian brachiopod-bivalves associations. This report adds to the growing evidence for an intriguing macroecological stasis: multiple meta-analytical surveys of present-day and fossil rhynchonelliform brachiopods conducted in recent years also point to persistent scarcity and low intensity of biotic interactions between brachiopods and drilling organisms throughout their evolutionary history.
Resumo:
A flow-injection (FI) system to match concentrations was used as an auto-diluter in multielement determination by inductively coupled plasma-mass spectrometry (ICP-MS). The flow system comprised loop-based injection or a timed valve that introduced a variable sample volume info a spray chamber through a standard Meinhard nebulizer of an ICP-MS. Routinely analyzed samples such as water, plant, and steel were selected. The accuracy of multielement determination was checked against water standard reference material from the National Institute of Standards and Technology (1643d), plant standard reference material from the National Bureau of Standards (1572 citrus leaves), and steel standard reference material from the National Bureau of Standards (AISI 4340). The measuring system was calibrated with a multielement solution, yielding a linear plot with good precision [relative standard deviation (RSD) < 3%, n = 12]. The results were in agreement at a 95% confidence level with the certified values for the reference materials and also with those obtained by continuous aspiration and by (FI) with a discrete volume. (C) 1999 John Wiley & Sons, Inc.
Resumo:
Background. Despite improvements in small bowel transplantation (SBTx), early referral of patients with irreversible intestinal failure (IF) remains a major obstacle. In this study we evaluated the demand for SBTx among seven surgical pediatric centers located at least 200 km from our center.Methods. From 1997 to 2001, 640 patients have been treated for neonatal diseases, including 248 who underwent a minor or major intestinal resection. Twenty-four patients with major resections presented with short gut syndrome, requiring total parenteral nutrition (TPN). The greatest demand was in postsurgical neonates with necrotizing enterocolitis, gastroschiesis, onphalocoeles, or midgut volvulus, and in three adults with postradiotherapy arteritis (n = 2) and mesenteric vein thromboses (n = 1). The median length of residual bowel after resection was 20 to 30 cm, without an ileocecal valve. Four patients were referred for SBTx evaluation; three died while awaiting a donor; 20 were not referred, among whom 14 died of TPN complications.Results. Approximately 62 children per year require nutritional support for IF, most of whom develop complications related to TPN. Because many patients who are TPN-dependent develop complications, we believe that early referral would reduce mortality.Conclusions. Greater medical awareness about the feasibility of SBTx procedures and earlier referral may improve results and quality of life after transplant.
Resumo:
The authors studied the formation, tributaries, lenght and the ostium of the coronary sinus, as well as the relationship of the venous walls to the myocardium and to the epicardium. The observations were made out of 143 hearts of subjects of different ages, and it was found that the most frequent display of the coronary sinus valve was a semilunar form (52 adults, 15 youngsters, 2 children, 3 newborn); it was also found valves in a cribiform or septal form. The absence of the valve of coronary sinus was noted in 53 cases (42 adults, 9 youngsters, 2 newborn). The valve of Vieussens was found, in some cases, at the level of the transition between the great cardiac vein and the coronary sinus, as well as others single or double parietal venous valves. The action of the valve of coronary sinus is also discussed by the authors.
Resumo:
PURPOSE--To provide a critical analysis of the fluid filled manometric system and M-mode echocardiography and, by their association, to standardize the determination of left ventricular (LV) pressure-diameter and stress-diameter relationships in humans. MATERIAL AND METHODS--The pressure curve and the LV M-mode image was obtained in 24 patients with cardiopathy. The dynamic characteristics of the fluid-filled system have been studied to define the amplitude, the resonance and the time gap of the pressure curve register. The delay of the pressure curve recording was determined in all cases by comparing pressure curve and echocardiographic aortic valve registers. The values of pressure, diameter, posterior wall thickness and LV meridional stress was calculated at every 0.02s. RESULTS--Preliminary analyses of the fluid-filled manometric system indicated that this system has variable dynamic characteristics. The pressure-diameter and stress-diameter loops obtained were similar to those of the literature. The values of end-systolic stress, percentage of fractional shortening, ejection fraction and circumferential fiber shortening rate of patients with dilated cardiomyopathy (n = 5) were significantly reduced when compared to the values of patients without left ventricular overload (n = 8) and patients with ventricular volume overload. It has been verified, also, that the retard of the pressure curve record introduced by the fluid-filled manometric system does not modify the values of these variables. CONCLUSION--The LV pressure-diameter and stress-diameter relationships obtained by the association of echocardiography and LV manometry showed functional characteristics of the ventricle that could not appear by the use of the echocardiography or by the LV manometry themselves.
Resumo:
Patients with congenital nasolacrimal obstruction (CNLO) were evaluated at the Lacrimal Apparatus Service of Botucatu Faculty of Medicine - UNESP from 1990 to 1993. 45 children were seen at this period with CNLO. The diagnosis was confirmed by dacryocystography (DCG). Obstruction was unilateral in 77,7% of the patients; 68,1% at Arlt Sinus and 43,6% had lacrimal sac grade 1. Probing was made in children older than 6 months, under general anaesthesia, after DCG was performed. Cure was greater in children age 6 to 12 months with obstruction at Hasner's Valve and without dilation of lacrimal sac.
Resumo:
In this paper we proposed to estimate the heritability of seven morphological characters that compose the sting apparatus ofthe Africanized honeybee workers. An experimental design to estimate genetic parameters was based on the method developed by Oldroyd and Moran. This method was modified to eliminate within-colony environmental effects associated with the additive genetic variance. The estimated h2 values ranged from 0.17 ± 0.11 (maximum width of bulb of sting stylet and height of the valve of right lancet) to 0.74 ± 0.30 (length of the lancet).