91 resultados para VALIDITY INDICES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to determine the critical speed (CS) for track cycling and to assess whether a lactate steady state occurs at this speed. Fourteen competitive cyclists performed the following tests on an official cycling track (333.3 m): 1) incremental test for determination of the intensity corresponding to 4 mM of blood lactate (onset of blood lactate accumulation, OBLA) and maximal oxygen uptake (VO(2)max); 2) CS: 3 maximal bouts for distances of 2, 4 and 6 km executed in random order and with a period of recovery of 40 to 50 min between bouts. CS was determined for each subject from the linear regression between the distance and the time taking to cycle it; 3) Endurance test in which subjects were instructed to pedal at 100% of their individually determined CS for 30 min. At the 10(th) and 30(th) min (or upon exhaustion), 25 mul of blood were collected from ear lobe for later analysis of blood lactate [Lac]b. An increase less than or equal to1 mM between 10 and 30 min of exercise was considered as the criterion for the occurrence of the lactate steady state. CS (49.6 +/- 8.6 ml.kg(-1).min(-1); 36.9 +/- 2.7 km.h(-1)) was significantly higher than OBLA (43.7 8.0 ml.kg(-1).min(-1); 35.24 +/- 2.6 km.h(-1)) although the two parameters were highly correlated (r=0.97). During the endurance test, only 8 of the 14 subjects completed the 30 min period at CS. of these 8 subjects, only 2 presented a lactate steady state. Time to exhaustion at CS was 20.3 +/- 1.6 min for the remaining 6 subjects. The 12 subjects who did not reach a lactate steady state presented mean [Lac]b values of 7.4 +/- 1.3 mM at 10 min and of 9.4 +/- 1.9 mM at the end of the test (exhaustion), characterizing an exercise intensity of high lactacidemia. on the basis of the present results, we can conclude that CS determined by a track cycling test seems to overestimate the intensity of the maximal lactate steady state for most subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the study was to determine the reproducibility and validity of DIAGNOdent in detecting active and arrested caries lesions on free smooth surfaces. Volunteers were selected from state schools of Piracicaba, São Paulo, Brazil. Overall, 220 lesions were clinically examined. Two specially trained ('calibrated') examiners performed both clinical and laser evaluations independently, and after a 1-week interval, the examinations were repeated, the intra-examiner agreement for the laser evaluation was substantial (kappa(ex1) = 0.79, kappa(ex2) = 0.71). There was almost perfect agreement between the two examiners for the clinical examination (kappa(ex1) = 0.95, kappa(ex2) = 0.85). The inter-examiner agreement showed substantial reproducibility (kappa = 0.77) for the laser examination and almost perfect agreement (kappa = 0.85) for the clinical evaluation. The validation criterion was the clinical examination of white spots, recorded as active or arrested. The sensitivity was 0.72 and the specificity was 0.73, which indicates that the DIAGNOdent was a good auxiliary method for detecting incipient caries lesions on free smooth surfaces. The utilization of both methods can improve the efficacy of caries diagnosis. Copyright (C) 2002 S. Karger AG, Basel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reproducibility and validity of self-perceived periodontal, dental, and temporomandibular joint (TMJ) conditions were investigated. A questionnaire was applied in interview to 200 adults aged from 35 to 44, who were attending as casual patients at Araraquara School of Dentistry, Sauo Paulo State University, Sauo Paulo, Brazil. Clinical examination was based on the guidelines of the World Health Organization manual. The interview and the clinical examination were performed in two occasions, by a calibrated examiner. Reproducibility and validity were, respectively, verified by kappa statistics (kappa) and sensitivity (Sen) and specificity (Spec) values, having clinical examination as the validation criterion. The results showed an almost perfect agreement for self-perceived TMJ (kappa=0.85) and periodontal conditions (kappa=0.81), and it was substantial for dental condition (kappa=0.69). Reproducibility according to clinical examination showed good results (kappa=0.73 for CPI index, kappa=0.96 for dental caries, and kappa=0.74 for TMJ conditions). Sensitivity and specificity values were higher for self-perceived dental (Sen=0.84, Spec=1.0) and TMJ conditions (Sen=1.0, Spec=0.8). With regard to periodontal condition, specificity was low (0.43), although sensitivity was very high (1.0). Self-perceived oral health was reliable for the examined conditions. Validity was good to detect dental conditions and TMJ disorders, and it was more sensitive than specific to detect the presence of periodontal disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction - the aim of this study was to analyze the validity of the critical speed (CS) to determine the speed corresponding to 4 mmol 1(-1) of blood lactate (S4) and the speed in a 30 min test (S30min) of swimmers aged 10-15 years.Synthesis of facts - CS, S4 and S30min were determined in 12 swimmers (eight boys and four girls) divided into two groups: 10-12 years and 13-15 years.Conclusion - CS was a good predictor of aerobic performance (S30min) independent of the chronological age, providing practical information about the aerobic performance state of young swimmers. (C) 2002, Editions scientifiques et medicates, Elsevier SAS. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Internet data collection is becoming increasingly popular in all research fields dealing with human perceptions, behaviors and opinions. Advantages of internet data collection, when compared to the traditional paper-and-pencil format, include reduced costs, automatic database creation, and the absence of researcher-related bias effects, such as availability and complete anonymity. However, the validity and reliability of internet gathered data must be established, in comparison to the usual paper-and-pencil accepted formats, before an inferential analysis can be done. In this study, we compared questionnaire data gathered from the internet with that from the traditional paper-and-pencil in a sample of college students. The questionnaires used were the Maslach Burnout Inventory - Student Survey (MBI-SS), the Oldenburg Burnout Inventory (OBI-SS) and the Copenhagen Burnout Inventory (CBI-SS). Data was gathered through a within-subject cross randomized and counterbalanced design, on both internet and paper-and-pencil formats. The results showed no interference in the application order, and a good reliability for both formats. However, concordance between answers was generally higher in the paper-and-pencil format than on the internet. The factorial structure was invariant in the three burnout inventories. Data gathered in this study supports the Internet as a convenient, user-friendly, comfortable and secure data gathering method which does not affect the accepted factorial structures existent in the paper format of the three burnout inventories used. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Considering the controversy in the literature regarding several aspects of temporomandibular dysfunction (TMD) in elderly populations and the absence of reliable data on elderly Brazilians in this field, this study consisted of an evaluation of TMD prevalence and the self-perception of oral health among institutionalised and community-dwelling elderly in Sao JosE dos Campos, Brazil.Two hundred and fifteen community-dwelling and 185 institutionalised elderly people were evaluated by the Helkimo anamnestic (Ai) and clinical dysfunction (Di) indices and answered a questionnaire using the Geriatric Oral Health Assessment Index (GOHAI).The major prevalence of TMD symptoms was for the Ai0 (symptom-free) group (69.5%), while the major prevalence of clinical signs was for the DiI (mild) group (56%). Women presented a higher AiII classification than men (chi(2) test, p = 0.049). Community-dwelling elderly presented a significantly lower Ai0 classification than the institutionalised ones (Two ratios equality test, p < 0.001). There was no relationship between the institutionalised status and the clinical dysfunction index for Di0 and DiIII classification (Two ratios equality test, p = 0.194 and 0.535 respectively). The institutionalised elderly presented greater (One-way anova = 0.005) self-perception of oral health (33.45) than did the community-dwelling group (32.66). There were only weak Pearson's correlations among the anamnestic (-33.0%) or clinical (-14.7%) findings by the TMD and GOHAI indices. Symptom-free (Ai0) institutionalised elderly presented better scores in all GOHAI dimensions and elderly representing an absence of clinical TMD signs (Di0) presented higher GOHAI physical dimension scores in both groups.The prevalence of TMD symptoms among this sample of elderly individuals was relatively low, self-perception of oral health was reasonable and a weak, inverse correlation was found between TMD signs and symptoms and elderly self-perception of oral health measured by the GOHAI index.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to analyze the effects of exercise mode on the validity of onset of blood lactate accumulation (OBLA-3.5-mM fixed blood lactate concentration) to predict the work-rate at maximal lactate steady state (MLSSwork-rate). Eleven recreationally active mates (21.3 +/- 2.9 years, 72.8 +/- 6.7 kg, 1.78 +/- 0.1 m) performed randomly incremental tests to determine OBLA (stage duration of 3 min), and 2 to 4 constants work-rate exercise tests to directly determine maximal lactate steady state parameters on a cycle-ergometer and treadmill. For both exercise modes, the OBLA was significantly correlated to MLSSwork-rate, (cycling: r = 0.81 p = 0.002; running: r = 0.94, p < 0.001). OBLA (156.2 +/- 41.3 W) was lower than MLSSwork-rate (179.6 +/- 26.4 W) during cycling exercise (p = 0.007). However, for running exercise, there was no difference between OBLA (3.2 +/- 0.6 m s(-1)) and MLSSwork-rate (3.1 +/- 0.4 m s(-1)). The difference between OBLA and MLSSworkrate on the cycle-ergometer (r = 0.86; p < 0.001) and treadmill (r = 0.64; p = 0.048) was significantly related to the specific MLSS. We can conclude that the validity of OBLA on predicting MLSSwork-rate is dependent on exercise mode and that its disagreement is related to individual variations in MLSS. (C) 2007 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quantification of the degree of activity of inflammatory bowel disease is assuming growing importance nowadays. The activity index of the disease can be attained by clinical and laboratorial indicators. For ulcerative colitis the mostly used clinical parameters are daily bowel movements and presence of bloody diarrhea whereas albumin, hemoglobin, ESR and positive acute phase protein measurements are the laboratory parameters. For Crohn's disease activity besides the daily bowel movements the presence of abdominal pain and discomfort sensation are also frequently used whereas the C-reactive protein is the most used laboratory test which is able to detect the disease reactivation even before the appearance of any clinical sign. The combinations of clinical signs with the laboratory tests earned the sympathy of the specialists and the set of ensembled indicators has been recognized by the author's name. In this sense, the classification of the ulcerative colitis activity originally proposed by Truelove and Witts deserves presently a wide acceptance whereas such agreement is still lacking for Crohn's disease activity. In the mean time, the Bristol index is clinically the most feasible, once the Crohn's disease activity index and the Van Hees index are considered too complex. However the latter indexes are still useful mainly for comparisons among multicentric data. It seems that the currently existing clinical signs used for Crohn's disease activity would be quantitatively improved by adding some easily made laboratory tests such as C-reactive protein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Water waves generated by a solid mass is a complex phenomenon discussed in this paper by numerical and experimental approaches. A model based on shallow water equations with shocks (Saint Venant) has developed. It can reproduce the amplitude and the energy of the wave quite well, but because it consistently generates a hydraulic jump, it is able to reproduce the profile, in the case of high relative thickness of slide, but in the case of small relative thickness it is unable to reproduce the amplitude of the wave. As the momentum conservation is not verified during the phase of wave creation, a second technique based on discharge transfer coefficient α, is introduced at the zone of impact. Numerical tests have been performed and validated this technique from the experimental results of the wave's height obtained in a flume.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of this study were to verify the effects of wet suits (WS) on the performance during 1500m swimming (V1500), on the velocity corresponding to the anaerobic threshold (VAT) and on the drag force (AD) as well as its coefficient (Cx). 19 swimmers randomly completed the following protocols on different days (with and without WS): 1) maximal performance of 1500m swimming; 2) VAT in field test, with fixed concentration of blood lactate (4 mM) and 3) determination of hydrodynamic indices (AD and Cx). The results demonstrated significant differences (p < 0.05) in the VAT (1.27±0.09; 1.21±0.06 m.s-1), and in the V1500 (1.21±0.08; 1.17±0.08 m.s-1), with and without WS, respectively. However the AD, and its Cx did not present significant differences (p>0.05) for the respective maximal speeds of swimming. In summary, we can conclude that WS allows swimmers to reach greater speeds in both, long- and short-course swims. This improvement can be related to the decrease of the AD, since with higher speeds (with WS) the subjects presented the same resistance, as they did when compared to speeds without a WS. Moreover, these data suggest that the methodology used in this study to determine the Cx is unable to detect the improvement caused by WS.