242 resultados para Tomografia por raios X


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The progress in radiology is related with the development of new systems of image formation with the lesser dose in the pacient. The improve of the dose in the pacient, without compromising the quality of the image, is one of the responsibilities of a medical physicist in a sector of diagnosis for image. This research has as objective to evaluate the conditions of use of an equipment of x-rays, from tests of quality control. The results gotten in this work have been part of data of an Effective Program of Quality Control (PECQ) of the sector of diagnosis for image of the Hospital das Clínicas da Faculdade de Medicina de Botucatu - UNESP (HCFMB-UNESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The X-ray fluorescence analysis (XRF) is an important technique for the qualitative and quantitative determination of chemical components in a sample. It is based on measurement of the intensity of the emitted characteristic radiation by the elements of the sample, after being properly excited. One of the modalities of this technique is the total reflection x-ray fluorescence (TXRF). In TXRF, the angle of refraction of the incident beam tends to zero and the refracted beam is tangent to the sample-support interface. Thus, there is a minimum angle of incidence that there is no refracted beam and all the incident radiation undergoes total reflection. As it is implemented in very small samples, in a film format, self-absorption effects should not very relevant. In this study, we evaluated the feasibility of using code MCNPX (Monte Carlo N - Particle eXtended), to simulate a measure implemented by the TXRF technique. In this way, it was verified the quality of response of a system by TXRF spectroscopy using synchrotron radiation as excitation beam for a simple setup, by retrieving the characteristic energies and the concentrations of the elements in the sample. The steps of data processing, after obtaining the excitation spectra, were the same as in a real experiment and included the obtaining of the sensitivity curve for the simulated system. The agreement between the theoretical and simulated values of Ka characteristic energies for different elements was lower than 1 % .The obtained concentration of the elements of the sample had high relatively errors ( between 6 and 60 % ) due mainly to lack of knowing about some realistic physical parameters of the sample , such as density . In this way, this result does not preclude the use of MCNPX code for this type of application

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Química - IQ

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate whether digitized images obtained from periapical radiographs taken with low dose of radiation could be improved with the aid of a computer software (PhotoStyler) for digital treatrnent. Serial and standardized radiographs of molar and premolar areas were studied. A total of 57 images equivalent to the radiographs taken with reduced exposure time ( 60 and 80% of the time considered normal), digitized and treated, were submitted to the evaluation of seven exanúners which compared them with those images without treatment. lt was verified that about 80% of the images equivalem to lhe radiographs taken with 60% reduction of ordinary exposure time were considered to having quality for supporting diagnosis. As for the images taken with 80% reduction of ordinary exposure time, about 50% of them were considered suitable for the sarne purpose

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introdução: Os processos industriais geram grandes quantidades de resíduos, representando um grande desperdício de matéria prima e causando impactos negativos ao meio ambiente. No caso dos resíduos gerados pelas fábricas de pás eólicas para aerogeradores de Sorocaba-S.P., eles podem ser reaproveitados na incorporação em cimento Portland. O interesse é utilizá-los na construção civil como blocos sem fins estruturais para construção de muros, guias, calçadas, pisos, etc. Os corpos confeccionados devem obedecer às normas técnicas brasileiras e as suas propriedades relativas à resistência, compressão, absorção de água e distribuição espacial dos resíduos nestes corpos devem ser avaliadas. Objetivos: Devido à importância de se conhecer as propriedades dos corpos produzidos com a incorporação de resíduos de pás eólicas, este trabalho faz uma avaliação através de imagens de raios X de sua distribuição espacial para verificar a viabilidade do emprego desta técnica no estudo da incorporação de resíduos para, futuramente, em conjunto com outras pesquisas que estão sendo realizadas, verificar a relação desta distribuição com as propriedades mecânicas dos corpos produzidos. Métodos: Objetivando a incorporação desse resíduo como substituto parcial dos agregados miúdos em argamassa, foram fabricados corpos de prova (CPs) seguindo as normas da ABNT-NBR 5738. Todos os corpos foram desmoldados após 24 horas de sua confecção e imersos em água por 28 dias para a cura. Utilizou-se o traço 3:1, areia e cimento, em relação a massa dos componentes, ou seja, para cada 300 g de areia adicionou-se 100 g de cimento. Na confecção de argamassa com resíduo utilizou-se o mesmo traço, porém com a substituição de parte da areia pelo resíduo. Foram fabricados CPs com 5%, 15%, 50% e 0% de resíduo para que este sirva de referência. Como os corpos possuem um formato cilíndrico, foram obtidas imagens em duas projeções: frontal e superior utilizando um equipamento digital com os seguintes parâmetros: 83 kVp e 16 mAs e, 85 kVp e 30 mAs, respectivamente. Resultados: As imagens mostram que na projeção frontal é possível verificar que a distribuição do resíduo nos corpos é homogênea, o que pode proporcionar uniformidade nos resultados de testes de resistência à compressão que serão realizados futuramente. Porém, na projeção superior ainda será necessário um estudo dos parâmetros que deverão ser utilizados no equipamento de raios X para melhorar a sua qualidade. Além disso, métodos de processamento digital de imagens poderão ser aplicados nas imagens para auxiliar na visualização dos resíduos incorporados. Também pode ser visto nas imagens que a forma utilizada para a incorporação do resíduo resulta na sua distribuição uniforme, compatível com o que se deseja neste tipo de incorporação.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Química - IQ

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Odontologia - FOA

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Biologia Geral e Aplicada - IBB

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o volume orbitário de coelhos recém-nascidos, enucleados ou eviscerados, sem ou com reposição do volume orbitário por esferas de polietileno poroso de 10 mm, usando a tomografia computadorizada, o teste de deslocamento de água e a medida da abertura orbitária por Image-J. MÉTODOS: Estudo experimental, usando 48 coelhos albinos, com idade de 42 dias, submetidos à evisceração ou enucleação, com implante de esfera de polietileno poroso de 10 mm de diâmetro ou sem implante. O lado esquerdo não foi submetido à cirurgia e foi usado como controle. Após 1, 3 e 6 meses, foram sacrificados quatro animais de cada grupo. Os crânios foram preparados para estudo do osso seco por maceração da peça, e analisados em relação ao volume orbitário por tomografia computadorizada, teste de deslocamento de água e avaliação da abertura orbitária usando o software Image-J. RESULTADOS: O volume das órbitas enucleadas ou evisceradas, com ou sem o uso do implante não apresentaram diferenças estatisticamente significativas (p<0,05) entre si, quando avaliadas por tomografia computadorizada, pelo teste de deslocamento de água e pelo Image-J. CONCLUSÃO: O desenvolvimento orbitário de coelhos com idade superior a 42 dias de vida não se altera quando se opta pela enucleação ou pela evisceração, ou quando se utiliza ou não implantes orbitários. O teste de deslocamento de água apresentou resultados semelhantes aos fornecidos pela tomografia, sugerindo-se sua utilização em experimentação científica.