66 resultados para Time measurements


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work describes an application of a multilayer perceptron neural network technique to correct dome emission effects on longwave atmospheric radiation measurements carried out using an Eppley Precision Infrared Radiometer (PIR) pyrgeometer. It is shown that approximately 7-month-long measurements of dome and case temperatures and meteorological variables available in regular surface stations (global solar radiation, air temperature, and air relative humidity) are enough to train the neural network algorithm and correct the observed longwave radiation for dome temperature effects in surface stations with climates similar to that of the city of São Paulo, Brazil. The network was trained using data from 15 October 2003 to 7 January 2004 and verified using data, not present during the network-training period, from 8 January to 30 April 2004. The longwave radiation values generated by the neural network technique were very similar to the values obtained by Fairall et al., assumed here as the reference approach to correct dome emission effects in PIR pyrgeometers. Compared to the empirical approach the neural network technique is less limited to sensor type and time of day (allows nighttime corrections).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The solid solution of PbZr1-xTixO3, known as lead-zirconate titanate (PZT), was probably one of the most studied ferroelectric materials, especially due to its excellent dielectric, ferroelectric and piezoelectric properties. The highest piezoelectric coefficients of the PZT are found near the morphotropic phase boundary (MPB) (0.46 <= x <= 0.49), between the tetragonal and rhombohedral regions of the composition-temperature phase diagram. Recently, a new monoclinic phase near the MPB was observed, which can be considered as a bridge between PZT's tetragonal and rhombohedral phases. This work is concerned with the study of the structural properties of the ferroelectric PZT (Zr/Ti = 52/48, 53/47) by hypertine interaction (HI) measurements obtained from experiments performed by using the nuclear spectroscopy time differential perturbed angular correlation (TDPAC) in a wide temperature range. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Measurements of internal friction as a function of temperature were carried out in samples of mobium containing different amounts of interstitial solutes (oxygen and nitrogen) and one sample of mobium containing initially only nitrogen as interstitial solute. The experimental spectra of internal friction as a function of temperature were obtained with a torsion pendulum of the inverted Ke-type and resolved, using the method of successive subtraction, into a series of constituent Debye peaks corresponding to different interactions. For each relaxation process it was possible to obtain the height (Q(max)(-1)) and temperature (T-p) of the peak, the activation energy (E) and the relaxation time (t(o)). The height, shape and temperature of these peaks depend on the concentration of interstitial elements. The observed peaks were associated with matrix-interstitial (Nb-O, Nb-N) and interstitial-interstitial (O-N) interaction processes. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ozone monitoring techniques utilize expensive instruments that are often large and heavy. These instruments are not easy to handle in the field, and their size also limits some sampling schemes, principally for indoor ozone determination. We have developed a lightweight, inexpensive, and sensitive method that offers flexibility to undertake measurements of ambient ozone in many environments, both indoor and outdoor. The method is based on the reaction of ozone with indigo blue dye. The indigo molecule contains 1 carbon double bond (C = C) that reacts with ozone and results in nearly colorless reaction products. During sample collection, 2 cellulose filters coated with 40 mu L of 1.0 x 10(-3) M indigo blue were used. The determinations were done spectrophotometrically at 250 and 600 nm. The analytical parameters studied were sampling time and flow rate. Analytical curves were constructed with concentrations ranging from 37 to 123 parts per billion by volume (ppbv) of standard ozone, at 0.4 L/min and 15 min sampling time. The detection limits achieved were 6 and 9 ppbv, respectively, at 250 and 600 nm. Considering interferences, measurements made at 250 nm gave more reliable and specific values for ozone.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Laboratory time-scale experiments were conducted on Carboniferous Limestone gravels from the Mendip Hills area, England, with the purpose of evaluating the release of Rn-222 to the water phase. The specific surface areas of the samples were 4.14 and 1.69 cm g(-1), which provided, respectively, values of 50.6 and 12.7 pCi for the released Rn. These results allowed the calculation of the emanation coefficient of this rock matrix with respect to the release of Rn, where completely different values corresponding to 23% and 6% were found, suggesting that the extent to which grain boundaries or imperfections in aggregates of micro-crystals of calcite intersect the particle surface certainly affects the Rn release. They also permitted the evaluation of models for the generation of Rn in rocks and transfer to water, in order to interpret the radioactivity due to this gas in groundwaters from the karstic aquifer of the Mendip Hills area, where the calculated activities in groundwater based on the values of 23% and 6% for the emanation coefficient were about 51 and 15 times higher than actually measured in groundwater. Therefore, the emanation coefficient in nature is considerably smaller than in the lab experiment, and another factor k (0 < k < 1) may be introduced into the equations related to the modelling, with the aim of adjusting the theoretical-practical results. (C) 1997 Elsevier B.V. Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports on time-resolved emission and excitation spectra measurement studies of Gd2SiO5:Ce3+ in powder or pellet samples, from spherical particles, in order to assign the Ce3+ ion transitions into two different symmetry sites. Samples were obtained from solid-state reaction of the spherical particles oxides, SiO2 and Gd2O3:Ce3+. From time-resolved spectroscopy measurements Ce3+ ion transitions occupying the two different gadolinium crystallographic sites in Gd2SiO5 were separated and assigned. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents a new approach for rainfall measurements making use of weather radar data for real time application to the radar systems operated by institute of Meteorological Research (IPMET) - UNESP - Bauru - SP-Brazil. Several real time adjustment techniques has been presented being most of them based on surface rain-gauge network. However, some of these methods do not regard the effect of the integration area, time integration and distance rainfall-radar. In this paper, artificial neural networks have been applied for generate a radar reflectivity-rain relationships which regard all effects described above. To evaluate prediction procedure, cross validation was performed using data from IPMET weather Doppler radar and rain-gauge network under the radar umbrella. The preliminary results were acceptable for rainfalls prediction. The small errors observed result from the spatial density and the time resolution of the rain-gauges networks used to calibrate the radar.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Twenty eight Mediterranean buffaloes bulls were scanned with real-time ultrasound (RTU), slaughtered, and fabricated into retail cuts to determine the potential for ultrasound measures to predict carcass retail yield. Ultrasound measures of fat thickness, ribeye area and rump fat thickness were recorded three to five days prior to slaughter. Carcass measurements were taken, and one side of each carcass was fabricated into retail cuts. Stepwise regression analysis was used to compare possible models for prediction of either kilograms or percent retail product from carcass mesaurements and ultrasound measures. Results indicate that possible prediction models for percent or kilograms of retail products using RTU measures were similar in their predictive power and accuracy when compared to models derived from carcass measurements. Both fat thickness and ribeye area were over-predicted when measured ultrasonically compared to measurements taken on the carcass in the cooler. The mean absolute differences for both traits are larger than the mean differences, indicating that some images were interpreted to be larger and some smaller than actual carcass measurements. Ultrasound measurements of REA and FT had positive correlations with carcass measures of the same traits (r=.96 for REA and r=.99 for FT). Standard errors of prediction currently are being used as the standard to certify ultrasound technicians for accuracy. Regression equations using live weight (LW), rib eye area (REAU) and subcutaneous fat thickness (FTU) between 12(th) and 13 (th) ribs and also over the biceps femoris muscle (FTP8) by ultrasound explained 95% of the variation in the hot carcass weight when measure immediately before slaughter.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents a review of recent developments in phase-stepping real-time holographic interferometry with photorefractive sillenite crystals. Quantitative results are shown in micro-rotation, micro-displacement, and micro-deformation measurements, and in wave-optics and surface analysis as well. The phase stepping was carried out in a four-frame process and the resulting phase map was unwrapped by applying a sin/cos filter. The experimental results are in good agreement with the ones obtained through other means, showing the promising potentialities of phase-stepping real-time holographic interferometry for in situ visualisation, monitoring and analysis in non-destructive testing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Clearance and transit time are parameters of great value in studies of digestive transit. Such parameters are nowadays obtained by means of scintigraphy and videofluoroscopy, with each technique having advantages and disadvantages. In this study we present a new, noninvasive method to study swallowing pharyngeal clearance (PC) and pharyngeal transit time (PTT). This new method is based on variations of magnetic flux produced by a magnetic bolus passing through the pharynx and detected by an AC biosusceptometer (ACB). These measurements may be performed in a simple way. cause no discomfort. and do not use radiation. We measured PC in 8 volunteers (7 males and I female. 23-33 years old) and PTT in 8 other volunteers (7 males and I female. 21-29 years old). PC was 0.82 +/- 0.10 s (mean +/- SD) and PTT was 0.75 +/- 0.03 s. The results were similar for PC but longer for PTT than those determined by means of other techniques. We conclude that the biomagnetic method can be used to evaluate PC and PTT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To determine the effects of storage of arterial and venous blood samples in ice water on blood gas and acid-base measurements.Design: Prospective, in vitro, laboratory study.Setting: School of veterinary medicine.Subjects: Six healthy dogs.Measurements and main results: Baseline measurements of partial pressure of oxygen (PO2), partial pressure of carbon dioxide (PCO2), pH, hemoglobin concentration (tHb), oxyhemoglobin saturation, and oxygen content (ContO(2)) were made. Bicarbonate (HCO3) and standard base excess (SBE) were calculated. Arterial and venous blood samples were separated into 1 and 3 mL samples, anaerobically transferred into 3 mL plastic syringes, and stored in ice water for 6 hours. Measurements were repeated at 15, 30 minutes, and 1, 2, 4, and 6 hours after baseline measurements. Arterial (a) PO2 increased significantly from baseline after 30 minutes of storage in the 1 mL samples and after 2 hours in the 3 mL samples. Venous (v) PO2 was significantly increased from baseline after 4 hours in the 1 mL samples and after 6 hours in the 3 mL samples. The pHa significantly decreased after 2 hours of storage in the 1 mL samples and after 4 hours in the 3 mL samples. In both the 1 and 3 mL samples, pHv decreased significantly only after 6 hours. Neither the arterial nor the venous PCO2 values changed significantly in the 1 mL samples and increased only after 6 hours in the 3 mL samples. No significant changes in tHb, ContO(2), SBE, or HCO3 were detected.Conclusions: the PO2 of arterial and venous blood increased significantly when samples were stored in plastic syringes in ice water. These increases are attributable to the diffusion of oxygen from and through the plastic of the syringe into the blood, which occurred at a rate that exceeded metabolic consumption of oxygen by the nucleated cells.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work particles of ZnO of size range 33-56 Angstrom were prepared by a sol-gel method. The effect of reaction time on the particle size of ZnO or ZnO:Ce was investigated by transmission electron microscopy measurements, UV-vis absorption and luminescence spectroscopy. A linear increase of the mean particle size is observed as a function of reaction time. The cerium-doped particles are bigger than the pure ZnO ones obtained at the same reaction time. A shift to lower energy at the maximum of the bands is observed in all absorption, emission and excitation spectra as a function of particle growth. From the absorption spectra the optical energy gap values (Eg) for these particles were determined. In the quantum size regime, Eg was found to decrease with particle growth.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a new non-destructive testing (NDT) for reinforced concrete structures, in order to identify the components of their reinforcement. A time varying electromagnetic field is generated close to the structure by electromagnetic devices specially designed for this purpose. The presence of ferromagnetic materials (the steel bars of the reinforcement) immersed in the concrete disturbs the magnetic field at the surface of the structure. These field alterations are detected by sensors coils placed on the concrete surface. Variations in position and cross section (the size) of steel bars immersed in concrete originate slightly different values for the induced voltages at the coils.. The values for the induced voltages were obtained in laboratory tests, and multi-layer perceptron artificial neural networks with Levemberg-Marquardt training algorithm were used to identify the location and size of the bar. Preliminary results can be considered very good.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)