35 resultados para Thread safe parallel run-time
Resumo:
The resistive-type superconducting fault current limiters (RSFCL) prototypes using YBCO-coated conductors have shown current limitation for medium voltage class applications for acting time up to 80 ms. By connecting an air-core reactor in parallel with the RSFCL, thus making an hybrid current limiter, one can extend the acting time for up to 1 s. In this work, we report the performance of a hybrid current limiter subjected to an AC peak fault current of 2 kA during 1 s for which within the first 80 ms the SFCL limits the current concurrently with the air-core reactor, and for the remaining 920 ms, only the air-core reactor limits the current. In order to evaluate the actual conditions for subsequent reconnection of RSFCL to the power grid, the hybrid fault current limiter was tested varying the time interval for recovery from 900 ms and 1.2 s, followed again by the concurrent operation of the hybrid limiter during 1 s (SFCL during 80 ms). From this evaluation test, the recovery time can be measured and compared using the voltage peak generated in superconducting module from the first and second fault test. The recovery time was also determined through the pulsed current method (PCM) on short-length sample test. The results showed that the fault current was limited from 1.9 kA down to 514 A after 1 cycle of 60 Hz frequency, with recovery time lower than 1.2 s for two subsequent fault current tests.
Resumo:
Resistive-type of superconducting fault current limiters (RSFCL) have been developed for medium voltage class aiming to operate at 1 MVA power capacity and short time recovery (< 2 s). A RSFCL in form of superconducting modular device was designed and constructed using 50 m-length of YBCO coated conductor tapes for operation under 1 kV / 1 kA and acting time of 0.1 s. In order to increase the acting time the RSFCL was combined with an air-core reactor in parallel to increase the fault limiting time up to 1 s. The tests determined the electrical and thermal characteristics of the combined resistive/ inductive protection unit. The combined fault current limiter reached a limiting current of 583 A, corresponding to a limiting factor of 3.3 times within an acting time of up to 1 s.
Resumo:
We compared the effects of two anesthesia protocols in both immediate recovery time (IRT) and postoperative respiratory complications (PRCs) after laparotomy for bariatric surgery, and we determined the association between the longer IRT and the increase of PRC incidence. We conducted the study in two stages: (i) in a randomized controlled trial (RCT), patients received either intervention (sevoflurane-remifentanil-rocuronium-ropivacaine) or control protocol (isoflurane-sufentanil-atracurium-levobupivacaine). All patients received general anesthesia plus continuous epidural anesthesia and analgesia. Treatment was masked for all, except the provider anesthesiologist. We defined IRT as time since anesthetics discontinuation until tracheal extubation. Primary outcomes were IRT and PRCs incidence within 15 days after surgery. We also analyzed post-anesthesia care unit (PACU) and hospital length of stays; (ii) after the end of the RCT, we used the available data in an extension cohort study to investigate IRT > 20 min as exposure factor for PRCs. Control protocol (n = 152) resulted in longer IRT (30.4 ± 7.9 vs 18.2 ± 9.6 min; p < 0.0001), higher incidence of PRCs (6.58 vs 2.5 %; p = 0.048), and longer PACU and hospital stays than intervention protocol (n = 200); PRC relative risk (RR) = 2.6. Patients with IRT > 20 min (n = 190) presented higher incidence of PRCs (7.37 vs 0.62 %; p < 0.0001); RR = 12.06. Intervention protocol, with short-acting anesthetics, was more beneficial and safe compared to control protocol, with long-acting drugs, regarding the reduction of IRT, PRCs, and PACU and hospital stays for laparotomy in bariatric patients. We identified a 4.5-fold increase in the relative risk of PRCs when morbid obese patients are exposed to an IRT > 20 min.
Resumo:
This paperaims to determine the velocity profile, in transient state, for a parallel incompressible flow known as Couette flow. The Navier-Stokes equations were applied upon this flow. Analytical solutions, based in Fourier series and integral transforms, were obtained for the one-dimensional transient Couette flow, taking into account constant and time-dependent pressure gradients acting on the fluid since the same instant when the plate starts it´s movement. Taking advantage of the orthogonality and superposition properties solutions were foundfor both considered cases. Considering a time-dependent pressure gradient, it was found a general solution for the Couette flow for a particular time function. It was found that the solution for a time-dependent pressure gradient includes the solutions for a zero pressure gradient and for a constant pressure gradient.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)