459 resultados para Teste de raios X


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The progress in radiology is related with the development of new systems of image formation with the lesser dose in the pacient. The improve of the dose in the pacient, without compromising the quality of the image, is one of the responsibilities of a medical physicist in a sector of diagnosis for image. This research has as objective to evaluate the conditions of use of an equipment of x-rays, from tests of quality control. The results gotten in this work have been part of data of an Effective Program of Quality Control (PECQ) of the sector of diagnosis for image of the Hospital das Clínicas da Faculdade de Medicina de Botucatu - UNESP (HCFMB-UNESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

By the early 20th century, the blood vessels could only be seen by anatomical studies. Shortly after the discovery of X-rays by Conrad Roentgen in 1895, the first experiments with radiographic imaging were performed with blood vessels. In 1905, the first experiment involving catheterization of arterial and venous system in dogs was performed and only in 1914 performed on living human patients. Parallel to these landmarks, there were advances in diagnostic imaging devices and the evolution of contrast substances was of utmost importance to the current angiography occupy a prominent role not only in terms of diagnosis, but also in the treatment of various disorders. The main objective of this review is to weave historical considerations and comparisons between the different methodologies used in angiography, because its importance; that may be in future, a veterinary diagnostic decisive test

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The X-ray fluorescence analysis (XRF) is an important technique for the qualitative and quantitative determination of chemical components in a sample. It is based on measurement of the intensity of the emitted characteristic radiation by the elements of the sample, after being properly excited. One of the modalities of this technique is the total reflection x-ray fluorescence (TXRF). In TXRF, the angle of refraction of the incident beam tends to zero and the refracted beam is tangent to the sample-support interface. Thus, there is a minimum angle of incidence that there is no refracted beam and all the incident radiation undergoes total reflection. As it is implemented in very small samples, in a film format, self-absorption effects should not very relevant. In this study, we evaluated the feasibility of using code MCNPX (Monte Carlo N - Particle eXtended), to simulate a measure implemented by the TXRF technique. In this way, it was verified the quality of response of a system by TXRF spectroscopy using synchrotron radiation as excitation beam for a simple setup, by retrieving the characteristic energies and the concentrations of the elements in the sample. The steps of data processing, after obtaining the excitation spectra, were the same as in a real experiment and included the obtaining of the sensitivity curve for the simulated system. The agreement between the theoretical and simulated values of Ka characteristic energies for different elements was lower than 1 % .The obtained concentration of the elements of the sample had high relatively errors ( between 6 and 60 % ) due mainly to lack of knowing about some realistic physical parameters of the sample , such as density . In this way, this result does not preclude the use of MCNPX code for this type of application

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Química - IQ

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate whether digitized images obtained from periapical radiographs taken with low dose of radiation could be improved with the aid of a computer software (PhotoStyler) for digital treatrnent. Serial and standardized radiographs of molar and premolar areas were studied. A total of 57 images equivalent to the radiographs taken with reduced exposure time ( 60 and 80% of the time considered normal), digitized and treated, were submitted to the evaluation of seven exanúners which compared them with those images without treatment. lt was verified that about 80% of the images equivalem to lhe radiographs taken with 60% reduction of ordinary exposure time were considered to having quality for supporting diagnosis. As for the images taken with 80% reduction of ordinary exposure time, about 50% of them were considered suitable for the sarne purpose

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introdução: Os processos industriais geram grandes quantidades de resíduos, representando um grande desperdício de matéria prima e causando impactos negativos ao meio ambiente. No caso dos resíduos gerados pelas fábricas de pás eólicas para aerogeradores de Sorocaba-S.P., eles podem ser reaproveitados na incorporação em cimento Portland. O interesse é utilizá-los na construção civil como blocos sem fins estruturais para construção de muros, guias, calçadas, pisos, etc. Os corpos confeccionados devem obedecer às normas técnicas brasileiras e as suas propriedades relativas à resistência, compressão, absorção de água e distribuição espacial dos resíduos nestes corpos devem ser avaliadas. Objetivos: Devido à importância de se conhecer as propriedades dos corpos produzidos com a incorporação de resíduos de pás eólicas, este trabalho faz uma avaliação através de imagens de raios X de sua distribuição espacial para verificar a viabilidade do emprego desta técnica no estudo da incorporação de resíduos para, futuramente, em conjunto com outras pesquisas que estão sendo realizadas, verificar a relação desta distribuição com as propriedades mecânicas dos corpos produzidos. Métodos: Objetivando a incorporação desse resíduo como substituto parcial dos agregados miúdos em argamassa, foram fabricados corpos de prova (CPs) seguindo as normas da ABNT-NBR 5738. Todos os corpos foram desmoldados após 24 horas de sua confecção e imersos em água por 28 dias para a cura. Utilizou-se o traço 3:1, areia e cimento, em relação a massa dos componentes, ou seja, para cada 300 g de areia adicionou-se 100 g de cimento. Na confecção de argamassa com resíduo utilizou-se o mesmo traço, porém com a substituição de parte da areia pelo resíduo. Foram fabricados CPs com 5%, 15%, 50% e 0% de resíduo para que este sirva de referência. Como os corpos possuem um formato cilíndrico, foram obtidas imagens em duas projeções: frontal e superior utilizando um equipamento digital com os seguintes parâmetros: 83 kVp e 16 mAs e, 85 kVp e 30 mAs, respectivamente. Resultados: As imagens mostram que na projeção frontal é possível verificar que a distribuição do resíduo nos corpos é homogênea, o que pode proporcionar uniformidade nos resultados de testes de resistência à compressão que serão realizados futuramente. Porém, na projeção superior ainda será necessário um estudo dos parâmetros que deverão ser utilizados no equipamento de raios X para melhorar a sua qualidade. Além disso, métodos de processamento digital de imagens poderão ser aplicados nas imagens para auxiliar na visualização dos resíduos incorporados. Também pode ser visto nas imagens que a forma utilizada para a incorporação do resíduo resulta na sua distribuição uniforme, compatível com o que se deseja neste tipo de incorporação.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Química - IQ

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this work was to develop a methodology for seed processing and X-ray analysis and to study imbibition pattern in seeds of candeia (Eremanthus incanus). Seeds were gathered in 2001 and 2002 in Morro do Pilar and Lavras respectively, processed and stored in a cold chamber (5ºC/60%RH) until the start of experiments. In order to identify unfilled seeds, a protocol was developed for X-ray use combining radiation energy (Kv) and exposure time (seconds). For elimination of unfilled seeds, an experiment was conducted using a South Dakota seed blower whereby different opening settings and ventilation times were combined. Original seed lots and categorized lots following radiograph viewing were tested by germination tests, with seeds being cleansed in sodium hypochlorite and scattered over blotting paper in 'gerboxes' and then taken to germinators with alternating temperatures of 20º-30ºC and 10 hours of light, for up to 15 days. Imbibition curves were determined under the conditions 30ºC, 20º-30ºC/10 hours of light and 30º-20ºC/10 hours of light. The X-ray protocol that best allowed viewing of internal seed structures was 30Kv for 45 seconds. Seed separation using the blower setting at a 3.0 opening for 30 seconds raised the number of embryonic seeds to values exceeding 99%, also raising the germination rates as a consequence. The imbibition pattern is three-phased and the germination process is completed in 72 hours. Under alternate temperatures, primary root growth is favored.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Química - IQ

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o volume orbitário de coelhos recém-nascidos, enucleados ou eviscerados, sem ou com reposição do volume orbitário por esferas de polietileno poroso de 10 mm, usando a tomografia computadorizada, o teste de deslocamento de água e a medida da abertura orbitária por Image-J. MÉTODOS: Estudo experimental, usando 48 coelhos albinos, com idade de 42 dias, submetidos à evisceração ou enucleação, com implante de esfera de polietileno poroso de 10 mm de diâmetro ou sem implante. O lado esquerdo não foi submetido à cirurgia e foi usado como controle. Após 1, 3 e 6 meses, foram sacrificados quatro animais de cada grupo. Os crânios foram preparados para estudo do osso seco por maceração da peça, e analisados em relação ao volume orbitário por tomografia computadorizada, teste de deslocamento de água e avaliação da abertura orbitária usando o software Image-J. RESULTADOS: O volume das órbitas enucleadas ou evisceradas, com ou sem o uso do implante não apresentaram diferenças estatisticamente significativas (p<0,05) entre si, quando avaliadas por tomografia computadorizada, pelo teste de deslocamento de água e pelo Image-J. CONCLUSÃO: O desenvolvimento orbitário de coelhos com idade superior a 42 dias de vida não se altera quando se opta pela enucleação ou pela evisceração, ou quando se utiliza ou não implantes orbitários. O teste de deslocamento de água apresentou resultados semelhantes aos fornecidos pela tomografia, sugerindo-se sua utilização em experimentação científica.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A osteoporose é uma doença crônica que atinge o esqueleto humano. OBJETIVO: Verificar os efeitos do treinamento resistido sobre a densidade mineral óssea (DMO), força muscular, equilíbrio e qualidade de vida em mulheres menopausadas em tratamento com alendronato. MÉTODOS: Participaram do estudo 16 voluntárias. Elas foram separadas em dois grupos: que praticaram o treino resistido (n = 9, 49,7 ± 4,2 idade) e que constituíram o grupo controle (n = 7, 53,8 ± 4,4 idade). Os instrumentos de avaliação seguintes foram usados: a absorciometria de dupla energia por raios X -DXA (que mediu a coluna lombar L2-L4, colo do fêmur, triângulo de Wards e trocanter maior), o Osteoporosis Assessment Questionnaire (OPAQ) e um teste de equilíbrio. O treinamento foi periodizado em 12 meses, divididos em seis ciclos com intensidade de 70-90% da carga máxima (10RM). Testes paramétricos (t ou Wilcoxon), para análise intragrupo e (Anova) para intergrupos, foram usados. RESULTADOS: Foram encontradas diferenças significativas favoráveis ao grupo que treinou nos sítios da lombar L2-L4 (6,8%, p = 0,001), colo do fêmur (4,8%, p = 0,005) e trocanter (0,76%, p = 0,005). Além de diferenças significativas também para o equilíbrio corporal (21,4%, p = 0,001), qualidade de vida (9,1%, p = 0,001) e todas as medidas de força como na pressão de pernas 45° (49,3%, p < 0,001). CONCLUSÃO: Os resultados sugerem que a metodologia aplicada ao treino resistido pode ser recomendada a mulheres menopausadas com baixa DMO.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJETIVO: Analisar a relação entre a prática de atividade física e composição corporal em mulheres na menopausa. METODOS: Participaram do estudo 62 mulheres, com 50 anos ou mais (61,2±7,6 anos), todas na menopausa. A prática de atividade física foi avaliada através do acelerômetro (minutos na semana e counts). A massa magra e massa gorda total e de tronco foram mensuradas com uso da absortimetria de raios X de dupla energia e expressas em valores percentuais. A relação entre as variáveis de composição corporal e a atividade física foi avaliada pela correlação de Spearman e de Pearson. As comparações entre grupos (de acordo com a prática de atividade física e idade) foram realizadas por meio do teste t independente e Mann-Whitney. RESULTADOS: O grupo de idade igual ou inferior a 59 anos apresentou maiores médias de atividade física total em counts (3.572.435 versus 2.843.840) e minutos por semana de atividade física moderada-vigorosa (273 minutos versus 156 minutos). As mulheres que acumularam 150 minutos ou mais de atividade física moderada-vigorosa apresentaram valores inferiores de massa gorda total (43,8 versus 47,2 kg/m²), valores superiores de massa corporal magra (53,8 versus 49,6 kg) e IMC reduzido (27,7 versus 30,46 kg/m²) quando comparadas àquelas com menos de 150 minutos de atividade física na semana. Apenas o tempo em atividades moderadas apresentou correlação negativa com o percentual de gordura total (r=-0,26, p<0,05); já atividade física total em counts correlacionou-se com o percentual de massa magra (r=0,30), percentual de gordura total (r=-0,32), gordura de tronco (r=-0,29), e IMC (r=-0,32), todas as correlações apresentaram significância estatística de p<0,05. CONCLUSÃO: Mulheres na menopausa com idade igual ou superior a 50 anos que apresentam minutos em atividades moderada e vigorosa, e counts de atividade física total superiores possuem níveis inferiores de massa gorda e superiores de massa magra.