102 resultados para Temperature Control
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
The aim of this paper was to evaluate the efficiency of the treatment of cassava wastewater, separately from the root washing water, by means of ascending flux anaerobic digesters, with separation of the phases, without temperature control or addition of chemical products and to evaluate its suitability by means of its physical and chemical characteristics for throwing in receiving body, public sewage system or application in fertilization and irrigation. After reactors had been stabilized, essays were conducted varying feeding flow with 8.0, 12.0 and 16.0 Ld-1 corresponding to a hydraulic retention time of 8.17, 5.44 and 4.08 days, respectively. The best reduction for organic load reduction were obtained with hydraulic retention times (HRT) of 8.17 and 5.44 days with mean efficiencies of 89.8 and 90.9%, respectively.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Incubation temperature (IT) was changed to evaluate if 6-wk-old birds become more tolerant to heat stress. After 13 d of incubation, 470 eggs were submitted to low (36.8degreesC), normal (37.8degreesC) and high (38.8degreesC) temperatures. At day 7 post-hatching, 144 birds were allocated to three rearing temperatures (48 birds/treatment): control/thermoneutral (35-24degreesC), high (33-30degreesC) or low (27-18degreesC) according to the age of the birds. Hsp70 levels in tissues of birds (1 d and 42 d), stress response (42 d) and performance were evaluated. High IT decreased brain (P < 0.01) and liver (P < 0.01) Hsp70 levels, whereas low IT decreased brain (P < 0.01) but increased heart (P < 0.01) Hsp70 levels in 1-d-old chicks. Birds incubated at a low temperature had higher (P < 0.05) feed intake (1-42d). High rearing temperature decreased feed intake (P<0.01) and liveweight (P<0.01). Colonic temperature was lower in birds incubated at a low temperature (P < 0.05) and higher in birds reared in a high temperature (P < 0.05) before heat stress. Birds reared in low temperature had higher increase in colonic temperature after heat stress (P < 0.05). Tissue Hsp70 levels were differently affected by rearing temperature, which affected broiler performance more than IT. Lower IT seemed to increase the sensitivity of birds to heat stress at market age.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Gibberellin inhibitor growth regulators are used for cotton (Gossypium hirsutum L.) canopy manipulation to avoid excess growth and yield losses. However, under temperatures below or over the optimum for cotton production the effect of mepiquat chloride (MC) has not always been significant. In this experiment, cotton plants were grown in growth chambers to study the response to MC as affected by temperature and to determine if an increase in dose could overcome the temperature effects. Mepiquat chloride was applied at rates of 0, 15 and 30 g ai ha-1 at the pinhead square stage. Plants were then grown under three temperature regimes: 25/15 °C, 32/22 °C, and 39/29 °C (day/night temperatures) for 51 days. Higher temperatures increased plant height, reproductive branches, fruit number, fruit abscission, and photosynthesis per unit area, but decreased leaf area and chlorophyll. The largest effect of MC on plant height was observed when the daily temperature was 32 °C, with nights of 22 °C, which was also best for plant growth. High temperatures not only decreased the effectiveness of MC on plant height control, but also caused lower dry matter and fruit number per plant. Low temperatures (25/15 ºC) decreased cotton growth and fruit retention, but a higher concentration of MC was required per unit of growth reduction as compared with 32/22 ºC. At high temperatures, the rate of MC to be applied must be disproportionately increased, because either plant growth is impaired by high temperature lessening the effect of MC, or degradation of MC within the plant is too rapid.
Power performance evaluation of an electric home fan with triac-based automatic speed control system
Resumo:
In order to provide a low cost system of thermal comfort, a common model of home fan, 40 cm diameter size, had its manual four-button control system replaced by an automatic speed control. The new control system has a temperature sensor feeding a microcontroller that, by using an optic coupling, DIAC or TRIAC-based circuit, varies the RMS value of the fan motor input voltage and its speed, according to the room temperature. Over a wide range of velocity, the fan net power and the motor fan input power were measured working under both control system. The temperature of the motor stator and the voltage waveforms were observed too. Measured values analysis showed that the TRIAC-based control system makes the fan motor work at a very low power factor and efficiency values. The worst case is at low velocity range where the higher fan motor stator temperatures were registered. The poor power factor and efficiency and the harmonics signals inserted in the motor input voltage wave by the TRIAC commutation procedure are correlated.
Resumo:
This work presents a numerical study of the tri-dimensional convection-diffusion equation by the control-volume-based on finite-element method using quadratic hexahedral elements. Considering that the equation governing this problem in its main variable may represent several properties, including temperature, turbulent kinetic energy, viscous dissipation rate of the turbulent kinetic energy, specific dissipation rate of the turbulent kinetic energy, or even the concentration of a contaminant in a given medium, among others, the wide applicability of this problem is thus evidenced. Three cases of temperature distributions will be studied specifically in this work, in addition to one case of pollutant dispersion upon analysis of the concentration of a contaminant in a fixed flow point. Some comparisons will be carried out against works found in the open literature, while others will be done according to each phenomenon characteristics.