58 resultados para SUBTHRESHOLD SIGNAL


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We perform a detailed theoretical study including decays and jet fragmentation of all the important modes of single top quark production and all the basic background processes at the upgraded Fermilab Tevatron and CERN LHC colliders. Special attention is paid to the complete tree level calculation of the QCD fake background which was not considered in previous studies. An analysis of the various kinematical distributions for the signal and backgrounds allow us to work out a set of cuts for an efficient background suppression and extraction of the signal. It is shown that the signal to background ratio after optimized cuts could reach about 0.4 at the Tevatron and 1 at the LHC. The remaining after cuts signal rate at the LHC for the lepton+jets signature is expected to be about 6.1 pb and will be enough to study single top quark physics even during LHC operation at a low luminosity. ©1999 The American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We perform a detailed analyses of the CERN Large Hadron Collider (LHC) capability to discover first generation vector leptoquarks through their pair production. We study the leptoquark signals and backgrounds that give rise to final states containing a pair e+e- and jets. Our results show that the LHC will be able to discover vector leptoquarks with masses up to 1.8-2.3 TeV depending on their couplings to fermions and gluons. ©1999 The American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a speech enhancement system (SES) based on a TMS320C31 digital signal processor (DSP) for real-time application. The SES algorithm is based on a modified spectral subtraction method and a new speech activity detector (SAD) is used. The system presents a medium computational load and a sampling rate up to 18 kHz can be used. The goal is load and a sampling rate up to 18 kHz can be used. The goal is to use it to reduce noise in an analog telephone line.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Research on Blindsight, Neglect/Extinction and Phantom limb syndromes, as well as electrical measurements of mammalian brain activity, have suggested the dependence of vivid perception on both incoming sensory information at primary sensory cortex and reentrant information from associative cortex. Coherence between incoming and reentrant signals seems to be a necessary condition for (conscious) perception. General reticular activating system and local electrical synchronization are some of the tools used by the brain to establish coarse coherence at the sensory cortex, upon which biochemical processes are coordinated. Besides electrical synchrony and chemical modulation at the synapse, a central mechanism supporting such a coherence is the N-methyl-D-aspartate channel, working as a 'coincidence detector' for an incoming signal causing the depolarization necessary to remove Mg 2+, and reentrant information releasing the glutamate that finally prompts Ca 2+ entry. We propose that a signal transduction pathway activated by Ca 2+ entry into cortical neurons is in charge of triggering a quantum computational process that accelerates inter-neuronal communication, thus solving systemic conflict and supporting the unity of consciousness. © 2001 Elsevier Science Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Grinding process is usually the last finishing process of a precision component in the manufacturing industries. This process is utilized for manufacturing parts of different materials, so it demands results such as low roughness, dimensional and shape error control, optimum tool-life, with minimum cost and time. Damages on the parts are very expensive since the previous processes and the grinding itself are useless when the part is damaged in this stage. This work aims to investigate the efficiency of digital signal processing tools of acoustic emission signals in order to detect thermal damages in grinding process. To accomplish such a goal, an experimental work was carried out for 15 runs in a surface grinding machine operating with an aluminum oxide grinding wheel and ABNT 1045 e VC131 steels. The acoustic emission signals were acquired from a fixed sensor placed on the workpiece holder. A high sampling rate acquisition system at 2.5 MHz was used to collect the raw acoustic emission instead of root mean square value usually employed. In each test AE data was analyzed off-line, with results compared to inspection of each workpiece for burn and other metallurgical anomaly. A number of statistical signal processing tools have been evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of salts, detergents and chaotropic agents on mass spectrometric analysis are relatively well understood, mainly due to their actions decreasing the performance of ESI interface in mass spectrometric analysis. However, there are few studies in the literature characterizing the effect of protein stabilization by glycerol, followed in some circumstances by the suppression of protein signal when ESI interface is used. The aim of the present research was to investigate in details the mass spectrometric behavior of some proteins in presence of high levels of glycerol during ESI-MS analysis. Thus, horse heart myoglobin and chicken ovalbumin were used as standard proteins. It was demonstrated that the presence of 1% (v/v) glycerol suppressed the signal of these proteins during the ESI-MS analysis, even when the sample nozzle potential was scanned from 28 to 80 V. However, when the glycerol concentration was decreased to 0.5% (v/v) and the sample cone voltage adjusted to 50 V, a perfect envelope of peaks was observed, allowing the spectrum deconvolution and the molecular mass determination with mass accuracy lower than 0.01% in each situation. A molecular explanation for this suppressive effect and for the analytical overcoming of this difficult is proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to analyze the electromyographic (EMG) signal behavior of rectus femoris (RF), vastus medialis (VM), vastus lateralis (VL) and biceps femoris (caput longum) (BFCL) from nine women during fatiguing dynamic and isometric knee extensions tests and to determine their EMGFT (Electromyographic Fatigue Threshold). Surface electrodes, biological signal acquisition module, analogical-digital converter board and specific software were used. The RMS (Root Mean Square) values obtained from concentric phase (80 to 30 degrees) of the dynamic knee extension andfrom isometric contraction were correlated with time on each load by linear regression analysis. The respective slopes were correlated with the correspondent load to determine the EMGFT. Force (Kgf) and median frequency - MF (Hz) obtained during MIVC (Maximal Isometric Voluntary Contraction) performed before and after the fatiguing tests were calculated in Matlab environment. The results demonstrated that the endurance time decreases with higher loads the EMG amplitude increase with time and was greater at higher loads, between muscles in dynamic exercise the RF and VL showed higher slopes, and in isometric exercise the VL showed the same behavior The EMGFT values were similar in both exercises; the force values predominantly decreased after fatiguing tests; however the MF only decreased after some loads. The protocols proposed allowed standardizing protocols at least to induce the fatigue process and to determine the EMGFT as an endurance indicative, which may be used to evaluate the effectiveness of rehabilitative or training interventions indicated to reduce muscle weakness and fatigue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper addresses the problem of processing biological data, such as cardiac beats in the audio and ultrasonic range, and on calculating wavelet coefficients in real time, with the processor clock running at a frequency of present application-specified integrated circuits and field programmable gate array. The parallel filter architecture for discrete wavelet transform (DWT) has been improved, calculating the wavelet coefficients in real time with hardware reduced up to 60%. The new architecture, which also processes inverse DWT, is implemented with the Radix-2 or the Booth-Wallace constant multipliers. One integrated circuit signal analyzer in the ultrasonic range, including series memory register banks, is presented. © 2007 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a tool box developed to read files describing a SIMULINK® model and translates it into a structural VHDL-AMS description. In translation process, all files and directory structures to simulate the translated model on SystemVision™ environment is generate. The tool box named MS2SV was tested by three models of commercially available digital-to-analogue converters. All models use the R2R ladder network to conversion, but the functionality of these three components is different. The methodology of conversion of the model is presents together with sort theory about R-2R ladder network. In the evaluation of the translated models, we used a sine waveform input signal and the waveform generated by D/A conversion process was compared by FFT analysis. The results show the viability of this type of approach. This work considers some of challenges set by the electronic industry for the further development of simulation methodologies and tools in the field of mixed-signal technology. © 2007 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We establish the conditions under which it is possible to construct signal sets satisfying the properties of being geometrically uniform and matched to additive quotient groups. Such signal sets consist of subsets of signal spaces identified to integers rings ℤ[i] and ℤ[ω] in ℤ2. © 2008 KSCAM and Springer-Verlag.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The alternate current biosusceptometry (ACB) is a biomagnetic technique used to study some physiological parameters associated with gastrointestinal (GI) tract. For this purpose it applies an AC magnetic field and measures the response originating from magnetic marks or tracers. This paper presents an equipment based on the ACB which uses anisotropic magnetoresistive (AMR) sensors and an inexpensive electronic support. The ACB-AMR developed consists of a square array of 6x6 sensors arranged in a firstorder gradiometer configuration with one reference sensor. The equipment was applied to capture magnetic images of different phantoms and to acquire gastric contraction activity of healthy rats. The results show a reasonable sensitivity and spatial-temporal resolution, so that it may be applied for imaging of phantoms and signal acquisition of the GI tract of small animals. © 2010 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a new method is proposed for noise reduction in speech signals in the wavelet domain. The method for signal processing makes use of a transfer function, obtained as a polynomial combination of three processings, denominated operators. The proposed method has the objective of overcoming the deficiencies of the thresholding methods and the effective processing of speech corrupted by real noises. Using the method, two speech signals are processed, contaminated by white noise and colored noises. To verify the quality of the processed signals, two evaluation measures are used: signal to noise ratio (SNR) and perceptual evaluation of speech quality (PESQ).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To analyze the components of the acoustic signal of swallowing using a specific software. Methods: Fourteen healthy subjects ranging in age from 20 to 50 years (mean age 31±10 years), were evaluated. Data collection consisted on the simultaneous capture of the swallowing audio with a microphone and of the swallowing videofluoroscopic image. The bursts of the swallowing acoustic signal were identified and their duration and the interval between them were later analyzed using a specific software, which allowed the simultaneous analyses between the acoustic wave and the videofluoroscopic image. Results: Three burst components were identified in most of the swallows evaluated. The first burst presented mean time of 87.3 milliseconds (ms) for water and 78.2 for the substance. The second burst presented mean time of 112.9 ms for water and 85.5 for the pasty substance. The mean interval between first and second burst was 82.1 ms for water and 95.3 ms for the pasty consistency, and between second and third burst was 339.8 ms for water and 322.0 ms for the pasty consistency. Conclusion: The software allowed the visualization of three bursts during the swallowing of healthy individuals, and showed that the swallowing signal in normal subjects is highly variable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The water column overlying the submerged aquatic vegetation (SAV) canopy presents difficulties when using remote sensing images for mapping such vegetation. Inherent and apparent water optical properties and its optically active components, which are commonly present in natural waters, in addition to the water column height over the canopy, and plant characteristics are some of the factors that affect the signal from SAV mainly due to its strong energy absorption in the near-infrared. By considering these interferences, a hypothesis was developed that the vegetation signal is better conserved and less absorbed by the water column in certain intervals of the visible region of the spectrum; as a consequence, it is possible to distinguish the SAV signal. To distinguish the signal from SAV, two types of classification approaches were selected. Both of these methods consider the hemispherical-conical reflectance factor (HCRF) spectrum shape, although one type was supervised and the other one was not. The first method adopts cluster analysis and uses the parameters of the band (absorption, asymmetry, height and width) obtained by continuum removal as the input of the classification. The spectral angle mapper (SAM) was adopted as the supervised classification approach. Both approaches tested different wavelength intervals in the visible and near-infrared spectra. It was demonstrated that the 585 to 685-nm interval, corresponding to the green, yellow and red wavelength bands, offered the best results in both classification approaches. However, SAM classification showed better results relative to cluster analysis and correctly separated all spectral curves with or without SAV. Based on this research, it can be concluded that it is possible to discriminate areas with and without SAV using remote sensing. © 2013 by the authors; licensee MDPI, Basel, Switzerland.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Inflammatory cytokines are associated with decreased insulin signal transduction. Moreover, local oral inflammation, such as that accompanying periodontal disease, is associated with insulin resistance and type 2 diabetes mellitus. The aim of this study was to evaluate the effect of periapical lesions (PLs) on insulin signaling and insulin sensitivity in rats. We hypothesized that PLs alter systemic insulin signaling and insulin sensitivity via elevated plasmatic tumor necrosis factor α (TNF-α). Methods: Wistar rats were divided into control (CN) and PL groups. PLs were induced by exposing pulpal tissue to the oral environment. After 30 days, insulin sensitivity was measured using the insulin tolerance test. After euthanization, maxillae were processed for histopathology. Plasmatic concentrations of tumor necrosis factor α (TNF-α) were determined via the enzyme-linked immunosorbent assay. Insulin signal transduction was evaluated using insulin receptor substrate tyrosine phosphorylation status and serine phosphorylation status in periepididymal white adipose tissue via Western blotting. For insulin signaling and insulin tolerance tests, the analyses performed were analysis of variance followed by the Tukey post hoc test. For TNF-α analysis, the Student's t test was used. In all tests, P <.05 was considered significant. Results: The rats with PLs showed higher plasmatic TNF-α, lower constant rate for glucose disappearance values, and reduced pp185 tyrosine phosphorylation status but no change in serine phosphorylation status in white adipose tissue after insulin stimulation. Conclusions: PLs can cause alterations to both insulin signaling and insulin sensitivity, probably because of elevation of plasmatic TNF-α. The results from this study emphasize the importance of the prevention of local inflammatory diseases, such as PLs, with regard to the prevention of insulin resistance. Copyright © 2013 American Association of Endodontists.