154 resultados para Root mean square error
Resumo:
Estimating equations of global radiation based on the sunshine duration were proposed for horizontal surface and with inclination of 12.85, 22.85 and 32.85° facing the North in Botucatu, SP, Brazil, in monthly, seasonal and annual groupings of data. Simple linear correlations were applied (for definition of the linear and angular coefficients of Angstrom-Prescott model), in a database measured in all three inclinations in different periods (22.85°: 04/1998 to 07/2001; 12.85°: 08/2011 to 02/2003; and 32.85°: 03/2003 to 12/2007) concomitant with horizontal measures and sunshine duration. The statistical performance of the model was analysed by the means absolute error (MBE), the square root of the mean square error (RMSE) and the index adjustment (d). The minimum global radiation transmissivity varied from 14.35% in August (12.85°) to 27.86% in December (32.85°) and the maximum transmissivity ranged between 62.10% and 78.90%, for June (32.85°) and December (12.85°). Increasing the angle of inclination surface increased the scattering and decreased the index of adjustment and performance. The worst results were found for application of the seasonal and annual models in the months of autumn and winter for 32.85° (RMSE below 42.93% and adjustment superior to 0.4693).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Com o objetivo de avaliar a importância da eletrocardiografia de alta resolução no diagnóstico da cardiomiopatia arritmogênica do ventrículo direito do Boxer, 20 cães sem evidências de doença cardíaca estrutural à avaliação ecodopplercardiográfica foram agrupados de acordo com a frequência de arritmias ventriculares, avaliadas pela eletrocardiografia ambulatorial de 24 horas, e submetidos ao exame eletrocardiográfico de alta resolução. Duração do complexo QRS filtrado, duração dos sinais de baixa amplitude (menor que 40µV) dos últimos 40 milissegundos do complexo QRS e raiz quadrada média da voltagem ao quadrado dos últimos 40 milissegundos do complexo QRS (RMS40) foram as variáveis avaliadas. Não foram observadas diferenças significativas entre os grupos em relação às variáveis estudadas. Sendo assim, os resultados do presente estudo sugerem que a eletrocardiografia de alta resolução não é uma ferramenta útil no auxílio diagnóstico da cardiomiopatia arritmogênica do ventrículo direito dos cães da raça Boxer que não apresentam alterações miocárdicas evidentes ou disfunção sistólica.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The objectives of this study were to compare the goodness of fit of four non-linear growth models, i.e. Brody, Gompertz, Logistic and Von Bertalanffy, in West African Dwarf (WAD) sheep. A total of 5274 monthly weight records from birth up to 180 days of age from 889 lambs, collected during 2001 to 2004 in Betecoucou breeding farm in Benin were used. In the preliminary analysis, the General Linear Model Procedure of the Statistical Analysis Systems Institute was applied to the dataset to identify the significant effects of the sex of lamb (male and female), type of birth (single and twin), season of birth (rainy season and dry season), parity of dam (1, 2 and 3) and year of birth (2001, 2002, 2003 and 2004) on the observed birth weight and monthly weight up to 6 months of age. The models parameters (A, B and k), coefficient of determination (112), mean square error (MSE) were calculated using language of technical computing package Matlab(R), 2006. The mean values of A, B and k were substituted into each model to calculate the corresponding Akaike's Information Criterion (AIC). Among the four growth functions, the Brody model has been selected for its accuracy of fit according to the higher R(2), lower MSE and A/C Finally, the parameters A, B and k were adjusted in Matlab(R) 2006 for the sex of lamb, year of birth, season of birth, birth type and the parity of ewe, providing a specific slope of the Brody growth curve. The results of this study suggest that Brody model can be useful for WAD sheep breeding in Betecoucou farm conditions through growth monitoring.
Resumo:
The ionospheric effect is one of the major errors in GPS data processing over long baselines. As a dispersive medium, it is possible to compute its influence on the GPS signal with the ionosphere-free linear combination of L1 and L2 observables, requiring dual-frequency receivers. In the case of single-frequency receivers, ionospheric effects are either neglected or reduced by using a model. In this paper, an alternative for single-frequency users is proposed. It involves multiresolution analysis (MRA) using a wavelet analysis of the double-difference observations to remove the short- and medium-scale ionosphere variations and disturbances, as well as some minor tropospheric effects. Experiments were carried out over three baseline lengths from 50 to 450 km, and the results provided by the proposed method were better than those from dual-frequency receivers. The horizontal root mean square was of about 0.28 m (1 sigma).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: It was reported that autonomic nervous system function is altered in subjects with chronic obstructive pulmonary disease (COPD). We evaluated short-and long-term fractal exponents of heart rate variability (HRV) in COPD subjects.Patients and methods: We analyzed data from 30 volunteers, who were divided into two groups according to spirometric values: COPD (n = 15) and control (n = 15). For analysis of HRV indices, HRV was recorded beat by beat with the volunteers in the supine position for 30 minutes. We analyzed the linear indices in the time (SDNN [standard deviation of normal to normal] and RMSSD [root-mean square of differences]) and frequency domains (low frequency [LF], high frequency [HF], and LF/HF), and the short-and long-term fractal exponents were obtained by detrended fluctuation analysis. We considered P < 0.05 to be a significant difference.Results: COPD patients presented reduced levels of all linear exponents and decreased short-term fractal exponent (alpha-1: 0.899 +/- 0.18 versus 1.025 +/- 0.09, P = 0.026). There was no significant difference between COPD and control groups in alpha-2 and alpha-1/alpha-2 ratio.Conclusion: COPD subjects present reduced short-term fractal correlation properties of HRV, which indicates that this index can be used for risk stratification, assessment of systemic disease manifestations, and therapeutic procedures to monitor those patients.
Resumo:
This work aims to investigate the efficiency of digital signal processing tools of acoustic emission signals in order to detect thermal damages in grinding process. To accomplish such a goal, an experimental work was carried out for 15 runs in a surface grinding machine operating with an aluminum oxide grinding wheel and ABNT 1045. The acoustic emission signals were acquired from a fixed sensor placed on the workpiece holder. A high sampling rate data acquisition system at 2.5 MHz was used to collect the raw acoustic emission instead of root mean square value usually employed. Many statistics have shown effective to detect burn, such as the root mean square (RMS), correlation of the AE, constant false alarm (CFAR), ratio of power (ROP) and mean-value deviance (MVD). However, the CFAR, ROP, Kurtosis and correlation of the AE have been presented more sensitive than the RMS.
Resumo:
The dynamics of hydration of meso and thermo citrate synthases has been investigated using the EEF1 methodology implemented with the CHARNM program. The native enzymes are composed of two identical subunits, each divided into a small and large domain. The dynamics behavior of both enzymes at 30 degrees C and 60 degrees C has been compared. The results of simulations show that during the hydration process, each subunit follows a different pathway of hydration, in spite of the identical sequence. The hydrated structures were compared with the crystalline structure, and the root mean square deviation (RMSD) of each residue along the trajectory was calculated. The regions with larger and smaller mobility were identified. In particular, helices belonging to the small domain are more mobile than those of the large domain. In contrast, the residues that constitute the active site show a much lower displacement compared with the crystalline structure. Hydration free energy calculations point out that Thermoplasma acidophilum citrate synthase (TCS) is more stable than chicken citrate synthase (CCS), at high temperatures. Such result has been ascribed to the higher number of superficial charges in the thermophilic homologue, which stabilizes the enzyme, while the mesophilic homologue denatures. These results are in accord with the experimental found that TCS keeps activity at temperatures farther apart from the catalysis regular temperature than the CCS. (c) 2005 Wiley Periodicals, Inc.
Resumo:
Background: The literature reports that the eccentric muscular action produces greater force and lower myoelectric activity than the concentric muscular action, while the heart rate (HR) responses are bigger during concentric contraction. Objectives: To investigate the maximum average torque (MAT), surface electromyographic (SEMG) and the heart rate (HR) responses during different types of muscular contraction and angular velocities in older men. Methods: Twelve healthy men (61.7 +/- 1.6years) performed concentric (C) and eccentric (E) isokinetic knee extension-flexion at 60 degrees/s and 120 degrees/s. SEMG activity was recorded from vastus lateralis muscle and normalized by Root Mean Square-RMS (mu V) of maximal isometric knee extension at 60 degrees. HR (beats/min) and was recorded at rest and throughout each contraction. The data were analyzed by the Friedman test for repeated measures with post hoc Dunn's test (p<0.05). Results: The median values of MAT (N.m/kg) was smaller and the RMS (mu V) was larger during concentric contraction (C60 degrees/s=2.80 and 0.99; C120 degrees/s=2.46 and 1.0) than eccentric (E60 degrees/s=3.94 and 0.85; E120 degrees/s=4.08 and 0.89), respectively. The HR variation was similar in the four conditions studied. Conclusion: The magnitude of MAT and RMS responses in older men were dependent of the nature of the muscular action and independent of the angular velocity, whereas HR response was not influenced by these factors.
Resumo:
Ties among event times are often recorded in survival studies. For example, in a two week laboratory study where event times are measured in days, ties are very likely to occur. The proportional hazards model might be used in this setting using an approximated partial likelihood function. This approximation works well when the number of ties is small. on the other hand, discrete regression models are suggested when the data are heavily tied. However, in many situations it is not clear which approach should be used in practice. In this work, empirical guidelines based on Monte Carlo simulations are provided. These recommendations are based on a measure of the amount of tied data present and the mean square error. An example illustrates the proposed criterion.