95 resultados para Relative Positioning
Resumo:
Aiming to evaluate the methodologies of surveys related with the specifications of Geo-referencing Rural Parcels in Brazil, established by INCRA (National Institute of Colonization and Agrarian Reform), in attendance to the Law 10.267/01, and considering aspects of precision and accuracy, a test area was set up in the Assentamento Florestan Fernandes, in the county of Presidente Bernardes, SP. This area was subdivided in three sub-areas in order to simulate the existence of three contiguous rural parcels. The first stage of work consisted in the implantation and determination of the control points coordinates in their respective areas. These control points were determined by the process of direct transport, using dual frequency (L1/L2) GPS receivers and through the process of traverse with baselines of up to 20 km, using single frequency receivers (L1). The coordinates of the points of the perimeter of the three sub-areas were determined using single frequency GPS receivers, from two survey methods, both using static relative positioning. The first one, so called traverse, each point that delimits the property was occupied successively, starting from the control point and closing at another. In other, denominated double irradiation, each point of the property was irradiated from two control points. These procedures were accomplished with the intention to define and to implement a mistake control strategy, to realize redundancy measurements and to use an adjustment method correctly, to obtain trustworthily values in the patterns demanded in each kind of survey. With the data collected and processed some analyses could be accomplished from the discrepancies between the coordinates obtained by different methodologies. The results show that this test area may be used to validate other methodologies and equipments. The results were satisfactory and attended the specifications of Geo-referencing Rural Parcel.
Resumo:
A method of determining spectral parameters p (slope of the phase PSD) and T (phase PSD at 1 Hz) and hence tracking error variance in a GPS receiver PLL from just amplitude and phase scintillation indices and an estimated value of the Fresnel frequency has been previously presented. Here this method is validated using 50 Hz GPS phase and amplitude data from high latitude receivers in northern Norway and Svalbard. This has been done both using (1) a Fresnel frequency estimated using the amplitude PSD (in order to check the accuracy of the method) and (2) a constant assumed value of Fresnel frequency for the data set, convenient for the situation when contemporaneous phase PSDs are not available. Both of the spectral parameters (p, T) calculated using this method are in quite good agreement with those obtained by direct measurements of the phase spectrum as are tracking jitter variances determined for GPS receiver PLLs using these values. For the Svalbard data set, a significant difference in the scintillation level observed on the paths from different satellites received simultaneously was noted. Then, it is shown that the accuracy of relative GPS positioning can be improved by use of the tracking jitter variance in weighting the measurements from each satellite used in the positioning estimation. This has significant advantages for scintillation mitigation, particularly since the method can be accomplished utilizing only time domain measurements thus obviating the need for the phase PSDs in order to extract the spectral parameters required for tracking jitter determination.
Resumo:
Ionospheric scintillations are caused by time-varying electron density irregularities in the ionosphere, occurring more often at equatorial and high latitudes. This paper focuses exclusively on experiments undertaken in Europe, at geographic latitudes between similar to 50 degrees N and similar to 80 degrees N, where a network of GPS receivers capable of monitoring Total Electron Content and ionospheric scintillation parameters was deployed. The widely used ionospheric scintillation indices S4 and sigma(phi) represent a practical measure of the intensity of amplitude and phase scintillation affecting GNSS receivers. However, they do not provide sufficient information regarding the actual tracking errors that degrade GNSS receiver performance. Suitable receiver tracking models, sensitive to ionospheric scintillation, allow the computation of the variance of the output error of the receiver PLL (Phase Locked Loop) and DLL (Delay Locked Loop), which expresses the quality of the range measurements used by the receiver to calculate user position. The ability of such models of incorporating phase and amplitude scintillation effects into the variance of these tracking errors underpins our proposed method of applying relative weights to measurements from different satellites. That gives the least squares stochastic model used for position computation a more realistic representation, vis-a-vis the otherwise 'equal weights' model. For pseudorange processing, relative weights were computed, so that a 'scintillation-mitigated' solution could be performed and compared to the (non-mitigated) 'equal weights' solution. An improvement between 17 and 38% in height accuracy was achieved when an epoch by epoch differential solution was computed over baselines ranging from 1 to 750 km. The method was then compared with alternative approaches that can be used to improve the least squares stochastic model such as weighting according to satellite elevation angle and by the inverse of the square of the standard deviation of the code/carrier divergence (sigma CCDiv). The influence of multipath effects on the proposed mitigation approach is also discussed. With the use of high rate scintillation data in addition to the scintillation indices a carrier phase based mitigated solution was also implemented and compared with the conventional solution. During a period of occurrence of high phase scintillation it was observed that problems related to ambiguity resolution can be reduced by the use of the proposed mitigated solution.
Resumo:
The Global Positioning System (GPS) transmits signals in two frequencies. It allows the correction of the first order ionospheric effect by using the ionosphere free combination. However, the second and third order ionospheric effects, which combined may cause errors of the order of centimeters in the GPS measurements, still remain. In this paper the second and third order ionospheric effects, which were taken into account in the GPS data processing in the Brazilian region, were investigated. The corrected and not corrected GPS data from these effects were processed in the relative and precise point positioning (PPP) approaches, respectively, using Bernese V5.0 software and the PPP software (GPSPPP) from NRCAN (Natural Resources Canada). The second and third order corrections were applied in the GPS data using an in-house software that is capable of reading a RINEX file and applying the corrections to the GPS observables, creating a corrected RINEX file. For the relative processing case, a Brazilian network with long baselines was processed in a daily solution considering a period of approximately one year. For the PPP case, the processing was accomplished using data collected by the IGS FORT station considering the period from 2001 to 2006 and a seasonal analysis was carried out, showing a semi-annual and an annual variation in the vertical component. In addition, a geographical variation analysis in the PPP for the Brazilian region has confirmed that the equatorial regions are more affected by the second and third order ionospheric effects than other regions.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to determine the relative potency of racemic ketamine and S(+)-ketamine for the hypnotic effect and to evaluate the clinical anesthesia produced by equianesthetic doses of these two substances in dogs. One hundred and eight dogs were allocated in groups R2, R2.5, R3, R6, R9, R12, S2, S2.5, S3, S6, S9, and S12, to receive by intravenous route 2, 2.5, 3, 6, 9, and 12 mg/kg of ketamine or S(+)-ketamine, respectively. A dose-effect curve was drawn with the dose logarithm and the percentage of dogs that presented hypnosis in each group. The curve was used to obtain a linear regression, to determine the effective doses 100 and the potency relationship. In another experimental phase, eight groups of five dogs received 3, 6, 9 and 12 mg/kg of ketamine or S(+)-ketamine to evaluate the periods of latency, hypnosis, and total recovery. The times in which the dogs reached the sternal position, attempted to stand up for the first time, recovered the standing position, and started to walk were also recorded. The hypnotic dose for ketamine was 9.82 +/- 3.02 (6.86-16.5) mg/kg and for S(+)-ketamine was 7.76 +/- 2.17 (5.86-11.5) mg/kg. The time of hypnosis was longer in R3 and the first attempt to stand up occurred early in R6 when compared with S3 and S6 respectively. When R9 (100% of hypnosis with ketamine) and S6 [100% of hypnosis with S(+)-ketamine] were compared (1:1.5 ratio), the time to sternal position (12 +/- 2.5 and 20.2 +/- 5.6 min respectively) and the total recovery time (45 +/- 5.5 and 60.2 +/- 5.2 min respectively) were significantly shorter with S(+)-ketamine. It was concluded that the potency ratio between ketamine and S(+)-ketamine in dogs is smaller than the one reported in other species, and that the dose obtained after a reduction of 50%, as usually performed in humans, would not be enough to obtain equianesthetic effects in dogs.
Resumo:
Objetivando avaliar o desenvolvimento relativo dos componentes do peso vivo (PV), dos cortes comerciais e dos tecidos da carcaça, utilizaram-se 40 cabritos Saanen. Os animais foram abatidos ao atingir 5,0; 12,5; 20,0; 27,5 e 35,0 kg de PV e a carcaça foi seccionada em paleta, pescoço, 1ª a 5ª costelas, 6ª a 13ª costelas, peito/fralda, lombo e perna. A perna foi dissecada em ossos, músculos e gordura. Utilizou-se a equação alométrica Y=aXb para estimar o desenvolvimento relativo. O crescimento do tecido ósseo foi precoce, o do tecido muscular intermediário e o da gordura crescimento tardio, uma vez que a gordura subcutânea é depositada mais tardiamente. Os cortes comerciais apresentaram coeficiente de alometria isogônico, com exceção do corte da 6ª a 13ª costelas e do peito/fralda. O desenvolvimento da carcaça e dos não-componentes da carcaça acompanhou o peso de corpo vazio. Cabritos com 35 kg de PV possuem proporção de músculos e relação músculo:osso adequadas, mas apresentam proporção de gordura maior que a observada nos animais abatidos com 20 kg de PV.
Resumo:
GPS precise point positioning (PPP) can provide high precision 3-D coordinates. Combined pseudorange and carrier phase observables, precise ephemeris and satellite clock corrections, together with data from dual frequency receivers, are the key factors for providing such levels of precision (few centimeters). In general, results obtained from PPP are referenced to an arbitrary reference frame, realized from a previous free network adjustment, in which satellite state vectors, station coordinates and other biases are estimated together. In order to obtain consistent results, the coordinates have to be transformed to the relevant reference frame and the appropriate daily transformation parameters must be available. Furthermore, the coordinates have to be mapped to a chosen reference epoch. If a velocity field is not available, an appropriated model, such as NNR-NUVEL-IA, has to be used. The quality of the results provided by this approach was evaluated using data from the Brazilian Network for Continuous Monitoring of the Global Positioning System (RBMC), which was processed using GIPSY-OASIS 11 software. The results obtained were compared to SIRGAS 1995.4 and ITRF2000, and reached precision better than 2cm. A description of the fundamentals of the PPP approach and its application in the integration of regional GPS networks with ITRF is the main purpose of this paper.
Resumo:
The quality of the vertical distribution measurements of humidity in the atmosphere is very important in meteorology due to the crucial role that water vapor plays in the earth's energy budget. The radiosonde is the humidity measurement device that provides the best vertical resolution. Also, radiosondes are the operational devices that are used to measure the vertical profile of atmospheric water vapor. The World Meteorological Organization (WMO) has carried out several intercomparison experiments at different climatic zones in order to identify the differences between the available commercial sensors. This article presents the results of an experiment that was carried out in Brazil in 2001 in which major commercial radiosonde manufacturers [e.g., Graw Radiosondes GmbH & Co., KG (Germany); MODEM (France); InterMet Systems (United States); Sippican, Inc. (United States); and Vaisala (Finland)] were involved. One of the main goals of this experiment was to evaluate the performance of the different humidity sensors in a tropical region. This evaluation was performed for different atmospheric layers and distinct periods of the day. It also considers the computation of the integrated water vapor (IWV). The results showed that the humidity measurements achieved by the different sensors were quite similar in the low troposphere (the bias median value regarding the RS80 was around 1.8%) and were quite dispersed in the superior layers (the median rms regarding the RS80 was around 14.9%).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
After removal of the Selective Availability in 2000, the ionosphere became the dominant error source for Global Navigation Satellite Systems (GNSS), especially for the high-accuracy (cm-mm) demanding applications like the Precise Point Positioning (PPP) and Real Time Kinematic (RTK) positioning.The common practice of eliminating the ionospheric error, e. g. by the ionosphere free (IF) observable, which is a linear combination of observables on two frequencies such as GPS L1 and L2, accounts for about 99% of the total ionospheric effect, known as the first order ionospheric effect (Ion1). The remaining 1% residual range errors (RREs) in the IF observable are due to the higher - second and third, order ionospheric effects, Ion2 and Ion3, respectively. Both terms are related with the electron content along the signal path; moreover Ion2 term is associated with the influence of the geomagnetic field on the ionospheric refractive index and Ion3 with the ray bending effect of the ionosphere, which can cause significant deviation in the ray trajectory (due to strong electron density gradients in the ionosphere) such that the error contribution of Ion3 can exceed that of Ion2 (Kim and Tinin, 2007).The higher order error terms do not cancel out in the (first order) ionospherically corrected observable and as such, when not accounted for, they can degrade the accuracy of GNSS positioning, depending on the level of the solar activity and geomagnetic and ionospheric conditions (Hoque and Jakowski, 2007). Simulation results from early 1990s show that Ion2 and Ion3 would contribute to the ionospheric error budget by less than 1% of the Ion1 term at GPS frequencies (Datta-Barua et al., 2008). Although the IF observable may provide sufficient accuracy for most GNSS applications, Ion2 and Ion3 need to be considered for higher accuracy demanding applications especially at times of higher solar activity.This paper investigates the higher order ionospheric effects (Ion2 and Ion3, however excluding the ray bending effects associated with Ion3) in the European region in the GNSS positioning considering the precise point positioning (PPP) method. For this purpose observations from four European stations were considered. These observations were taken in four time intervals corresponding to various geophysical conditions: the active and quiet periods of the solar cycle, 2001 and 2006, respectively, excluding the effects of disturbances in the geomagnetic field (i.e. geomagnetic storms), as well as the years of 2001 and 2003, this time including the impact of geomagnetic disturbances. The program RINEX_HO (Marques et al., 2011) was used to calculate the magnitudes of Ion2 and Ion3 on the range measurements as well as the total electron content (TEC) observed on each receiver-satellite link. The program also corrects the GPS observation files for Ion2 and Ion3; thereafter it is possible to perform PPP with both the original and corrected GPS observation files to analyze the impact of the higher order ionospheric error terms excluding the ray bending effect which may become significant especially at low elevation angles (Ioannides and Strangeways, 2002) on the estimated station coordinates.
Resumo:
In Brazil, there have been several GPS applications and with the introduction of the Law 10.267/2001 that among other dispositions, deals with georeferencing of the rural parcels. However, most commercial softwares of processing and adjustment of GPS data don't let users to evaluate their results in a reliable way. For example, the constraints are normally used as absolute, which provides results with very optimists precisions. The adoption of additional analyses and the implementation of softwares can reduce these kinds of problems. Thus, a software for adjustment of GPS networks was developed, aiming at assisting the requirements of the Law 10.267/2001 in a reliable way. In this context, in this work it is analyzed the adjustments of GPS networks, by using absolute and relative constraints. In the latter, the adjustments were accomplished considering and not considering the correlations among the coordinate positions.
Resumo:
Considering that counting the percentage of CD4 T lymphocytes can add prognostic information regarding patients infected with HIV, the aim of this study was to evaluate the percentage values of CD4+ T lymphocytes from 81 patients determined by flow cytometry and estimated by flow cytometry in conjunction with a hematology counter. Means were compared through the Student's t-test. Pearson's correlation was determined, and the agreement between results was tested by Bland-Altman. The level of significance was P < 0.05. It was found a significantly higher mean difference between the relative values of CD4+ T lymphocytes to the hematologic counter (P < 0.05), for all strata studied. Positive and significant correlations (P < 0.01) were found between the strata CD4 < 200 cells/mL (r = 0.93), between 200 and 500 cells/mL (r = 0.65), and >500 cells/mL (r = 0.81). The limits of agreement were 1.0 +/- 3.8% for the stratum of CD4 < 200 cells/mL, approximately 2.2 +/- 13.5% for the stratum of CD4 between 200 and 500 cells/mL, and approximately 6.2 +/- 20.4% for the stratum > 500 cells/mL. The differences in the percentages of CD4+ T lymphocytes obtained by different methodologies could lead to conflict when used in clinical decisions related to the treatment and care of people infected with HIV.
Resumo:
Special diets are used to mitigate many human diseases. When these diets require changes in carbohydrate content, then sweetness becomes an important characteristic. The range of low-calorie sweeteners available to the food industry is expanding. It is essential to have an exact knowledge of the relative sweetness of various sweeteners in relation to different sucrose concentrations. The objective of this study was to determine the variation on the relative sweetness of aspartame (APM), stevia [Stevia rebaudiana (Bert.) Bertoni] leaf extract (SrB) and the mixture cyclamate/saccharin - two parts of cyclamate and one part of saccharin - (C/S) with the increase in their concentrations, and in neutral and acid pH in equi-sweet concentration to 10% sucrose, using magnitude estimation. Sweetness equivalence of SrB in relation to sucrose concentrations of 20% or higher and of APM and C/S to sucrose concentrations of 40% or higher could not be determined, because a bitter taste predominated. The potency of all sweeteners decreased as the level of sweetner increased. In equi-sweet concentration of sucrose at 10%, with pH 7.0 and pH 3.0, the potency was practically the same for all sweeteners evaluated.