42 resultados para Perpetual motion
Resumo:
The recovery of sperm from the epididymal cauda may be the last chance to obtain genetic material when sudden death or serious injuries occur in valuable stallions. However, the lack of technical knowledge regarding the storage and transportation of the epididymis often prevents the preservation of the sperm. Therefore, the aim of this study was to compare sperm parameters of sperm obtained immediately after orchiectomy with sperm recovered from epididymal cauda at different times after storage at 5°C and at room temperature (RT). For that, 48 stallions of different breeds were used. In group 1 (control group), eight stallions were used, and the harvest of the epididymal sperm was performed immediately after orchiectomy. In group 2, 40 stallions were used, which were divided into five groups according to the storage time of the epididymis after orchiectomy (6, 12, 18, 24, or 30 hours), making a total of eight stallions per group. One epididymis of each stallion was stored at 5°C, and the contralateral epididymis was stored at RT, both for the same period. The sperm parameters of total motility, progressive motility, progressive linear velocity, curvilinear velocity, percentage of rapid sperm, and plasma membrane integrity were evaluated in all the groups after sperm recovery, resuspension in a sperm freezing diluent, and thawing. In conclusion, the storage of the testis-epididymis complex at 5°C provided better preservation of epididymal sperm than the storage at RT, and regardless of the temperature, the progressive motility is the sperm parameter that is most sensitive to storage time. © 2013 Elsevier Inc.
Resumo:
STUDY DESIGN. Observational cohort study. OBJECTIVE. To investigate spinal coordination during preferred and fast speed walking in pain-free subjects with and without a history of recurrent low back pain (LBP). SUMMARY OF BACKGROUND DATA. Dynamic motion of the spine during walking is compromised in the presence of back pain (LBP), but its analysis often presents some challenges. The coexistence of significant symptoms may change gait because of pain or adaptation of the musculoskeletal structures or both. A history of LBP without the overlay of a current symptomatic episode allows a better model in which to explore the impact on spinal coordination during walking. METHODS. Spinal and lower limb segmental motions were tracked using electromagnetic sensors. Analyses were conducted to explore the synchrony and spatial coordination of the segments and to compare the control and subjects with LBP. RESULTS. We found no apparent differences between the groups for either overall amplitude of motion or most indicators of coordination in the lumbar region; however, there were significant postural differences in the mid-stance phase and other indicators of less phase locking in controls compared with subjects with LBP. The lower thoracic spinal segment was more affected by the history of back pain than the lumbar segment. CONCLUSION. Although small, there were indicators that alterations in spinal movement and coordination in subjects with recurrent LBP were due to adaptive changes rather than the presence of pain. © 2013, Lippincott Williams & Wilkins.
Resumo:
The tapping mode is one of the mostly employed techniques in atomic force microscopy due to its accurate imaging quality for a wide variety of surfaces. However, chaotic microcantilever motion impairs the obtention of accurate images from the sample surfaces. In order to investigate the problem the tapping mode atomic force microscope is modeled and chaotic motion is identified for a wide range of the parameter's values. Additionally, attempting to prevent the chaotic motion, two control techniques are implemented: the optimal linear feedback control and the time-delayed feedback control. The simulation results show the feasibility of the techniques for chaos control in the atomic force microscopy. © 2012 IMechE.
Resumo:
We consider the non-Markovian Langevin evolution of a dissipative dynamical system in quantum mechanics in the path integral formalism. After discussing the role of the frequency cutoff for the interaction of the system with the heat bath and the kernel and noise correlator that follow from the most common choices, we derive an analytic expansion for the exact non-Markovian dissipation kernel and the corresponding colored noise in the general case that is consistent with the fluctuation-dissipation theorem and incorporates systematically non-local corrections. We illustrate the modifications to results obtained using the traditional (Markovian) Langevin approach in the case of the exponential kernel and analyze the case of the non-Markovian Brownian motion. We present detailed results for the free and the quadratic cases, which can be compared to exact solutions to test the convergence of the method, and discuss potentials of a general nonlinear form. © 2013 Elsevier B.V. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This study at aims performing the stability analysis of the rotational motion to artificial satellites using quaternions to describe the satellite attitude (orientation on the space). In the system of rotational motion equations, which is composed by four kinematic equations of the quaternions and by the three Euler equations in terms of the rotational spin components. The influence of the gravity gradient and the direct solar radiation pressure torques have been considered. Equilibrium points were obtained through numerical simulations using the softwares Matlab and Octave, which are then analyzed by the Routh-Hurwitz Stability Criterion.
Resumo:
Background: Although the effect of symptomatic back pain on functional movement has been investigated, changes to spinal movement patterns in essentially pain-free people with a history of recurrent back pain are largely unreported. Reaching activities, important for everyday and occupational function, often present problems to such people, but have not been considered in this population. The purpose of this study was to compare the amplitude and timing of spinal and hip motions during two, seated reaching activities in people with and without a history of recurrent low back pain (RLBP).Methods: Spinal and hip motions during reaching downward and across the body, in both directions, were tracked using electromagnetic sensors. Analyses were conducted to explore the amplitudes, velocities and timings of 3D segmental movements and to compare controls with subjects with recurrent, but asymptomatic lumbar or lumbosacral pain.Findings: We detected significant differences in the amplitude and timing of movement in the lower thoracic region, with the RLBP group restricting movement and demonstrating compensatory increased motion at the hip. The lumbar region displayed no significant between-group differences. The order in which the spinal segments achieved peak velocity in cross-reaching was reversed in RLBP compared to controls, with lumbar motion leading in controls and lagging in RLBP.Interpretation: Subjects with a history of RLBP show a number of altered kinematic features during reaching activities which are not related to the presence or intensity of pain, but which suggest adaptive changes to movement control. (C) 2013 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A mapping scheme is presented which takes quantum operators associated to bosonic degrees of freedom into complex phase space integral kernel representatives. The procedure consists of using the Schrödinger squeezed state as the starting point for the construction of the integral mapping kernel which, due to its inherent structure, is suited for the description of second quantized operators. Products and commutators of operators have their representatives explicitly written which reveal new details when compared to the usual q-p phase space description. The classical limit of the equations of motion for the canonical pair q-p is discussed in connection with the effect of squeezing the quantum phase space cellular structure. © 1993.
Resumo:
During the last 30 years the Atomic Force Microscopy became the most powerful tool for surface probing in atomic scale. The Tapping-Mode Atomic Force Microscope is used to generate high quality accurate images of the samples surface. However, in this mode of operation the microcantilever frequently presents chaotic motion due to the nonlinear characteristics of the tip-sample forces interactions, degrading the image quality. This kind of irregular motion must be avoided by the control system. In this work, the tip-sample interaction is modelled considering the Lennard-Jones potentials and the two-term Galerkin aproximation. Additionally, the State Dependent Ricatti Equation and Time-Delayed Feedback Control techniques are used in order to force the Tapping-Mode Atomic Force Microscope system motion to a periodic orbit, preventing the microcantilever chaotic motion