55 resultados para PUMPS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia de Materiais - FC

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Agricultura) - FCA

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Geociências e Meio Ambiente - IGCE

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work has the purpose to explain how the sugar and alcohol sector works, detail all the processes which uses pumps and assist in the selection and specification of pumps attached with engines, that will make part in important industry processes in the manufacture of sugar and alcohol. A bibliographic revision about the working of sugar and alcohol sector and about pumps were made to help the analysis of a case. This case had the purpose to analyze the selected pumps that were part of a initial project of an industry which aimed a future expansion. The pumps that were selected to made part of the initial project were over dimensioned and were operating out of the best performance point, making the pumps inefficient because the expansion didn't happened. The solution was to select another pump with bigger performance and less power consumption to have a decrease in the energy consumption and in the operational costs of the industry and using the extra electric energy in the industry or selling it

Relevância:

10.00% 10.00%

Publicador:

Resumo:

On the field of the projects of hydraulic systems exists a lot of worries when we talk about the calculate of hydraulic pumps. In this case some facts must be considerate: length of tubes, fluid characteristics, height gauge, temperature, pressure, characteristics of tubes, flow required and others. For that mathematic calculates must be developed with the objective to optimize hydraulic pumps and agree to find an ideal machine (that don't requires more energy than necessary or less energy than it requires; that is the more critical case, cause exists the risk that the fluid pumped do not agree to become in your destiny). The wrong calculate of this machine can super-size its, bringing an excessive energy consumption. Actually it's an important subject because we are in the age of lack of energy what turn it more expensive. So the correct sizing of a hydraulic pump is connected with the fact that you have to uses the enough energy resources avoiding waste. The calculate of ideal pump in the pumping system is studied during years and a lot of specialists in this subject develop equations and theories to calculate its. Some researches study about this subject and all of them become to the same conclusion: to find the ideal pump we have to know the characteristics of fluid (cinematic viscosity), the required flow , overall yield (overall of motor x overall of pump) the high gauge or discharge pressure and the loss of repression. The pressure drop can be calculated with different theories: using Hazen-Williams, Darcy e Weisbach or Chézy (1775 - that starts the researches to calculate the pressure drop). Although the most used theory and what is most near to reality is the Darcy's equation. So, in this job the Darcy's equation were choice to calculate the drop pressure that consider what kind of flow we are studying: laminar or turbulent. The determination of the best pump to be used in the ... ( complete abstract click eletronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study is about a heating line that uses thermal oil. It is located in a facility that produces interlayers used in cars windshields. A plastic resin is melted and is sent to a matrix called DIE where the interlayers are produced. The DIE needs to receive heat from the circulation of thermal oil in four different regions of its interior, to ensure the correct thickness of the interlayer. The thermal energy is provided by electric heaters and the flow of thermal oil is impelled by four mechanically sealed centrifugal pumps (one per region). The key point of this study is the fact that these four pumps of the system have reported successive failures in the mechanical seals. Apparently, a poorly designed project has burdened the system intermittently. The pumps operation condition is located in a region of low efficiency, according to the characteristic curves. This fact is the source of the noticeable reduced time between failures. Changes in the configuration of the facility and in the number of pumps will be proposed, aiming to achieve higher operational efficiency. The proposals will be mathematically analyzed according to the Hydraulic Institute criteria. At the same time, we will also keep focus on an in-depth study of a heating system structure, starting with a detailed approach for each component and discussion about its real need and economic viability. At the end of this paper it is shown that the gain in efficiency achieved with the new proposed configuration reflects not only in the reduction of maintenance costs, but also a potential improvement in energy efficiency. It is shown that these two aspects are closely related and together form the basis for the design of a reliable and efficient pumping system

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present work aims to conduct a study of the economic feasibility of the implementation of variable frequency inverters in pump systems with variable flow rates. The concern with the reduction of energy expenditure in industries raised in 2001 due to the energy crisis that hit Brazil at that time, forcing industries to reduce their electric costs under penalty of fines if this were not done (MOREIRA, 2008). Frequency inverter is an electronic device that allow greater control in the operation of pumping systems and also a reduction in electrical consumption, being a viable solution to achieve a reduction in energy consumption. For the development of this work, approaching important topics in pumping systems was necessary in order to make a correct choice of hydraulic pumping and also other components responsible for the operation of the system , such as electric motors and frequency inverters. In the case study, a theoretical analysis of the behavior of electrical consumption in systems with variable flow rates was performed, comparing when the system is operated via frequency inverters and when the system is operated without such a device. As expected, the result of the implantation of the device was quite satisfactory, and the primary goal of reducing energy expenditure was achieved. Also important to highlight the environmental issue of this work, as all forms of energy production affects nature in some way, achieving a reduction in consumption also contributes indirectly in environmental conservation