35 resultados para Oscillatory bath


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work shows a study about the growing of ZnO nanorods by chemical bath deposition (CBD) and its application as gas sensor. It was prepared ZnO nanorods and Au decorated ZnO nanorods and the samples were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM) and gas sensing response measurements. The results obtained by XRD show the growth of ZnO phase. It was possible to observe the formation of uniform dense well-aligned ZnO nanorods. The results obtained also revealed that Ag nanoparticles have decorated the surface of ZnO nanorods successfully. Au nanoparticles with diameter of a few nanometers were distributed over the ZnO surface nanorods. The gas sensing response measurements showed a behavior of n type semiconductor. Furthermore, the Au-functionalized ZnO nanorods gas sensors showed a considerably enhanced response at 250 and 300 °C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diottix(r) was calibrated at 25 Hz to achieve the frequency indicated in literature as being effective to mobilize the airways secretions. However, the amplitude and frequency of the waves generated by the equipment in different regions of the chest still need to be investigated. The objective of this study was to analyze the frequency and amplitude of waves generated by Diottix(r) in chests of healthy subjects. Diottix(r) was used in the anterior and posterior regions of the chest. The mechanical waves were captured using stethoscopes connected to electret microphones, which were connected to a digital oscilloscope. Frequency and amplitude data were recorded by the stethoscope, positioned in six points in the anterior region and six in the posterior region of the chest, following the positions commonly used in pulmonary auscultation. Signals were recorded and transferred to a computer with software for their analysis. The frequency of waves did not present a significant change (from 24.9 to 26.4 Hz). The wave amplitude in the anterior versus the posterior region in each area of the lung, the upper, middle and lower, had differences. Diottix(r) produces frequencies in the chest according to the calibrated; thus, it can be a complementary resource to bronchial hygiene maneuvers. The amplitudes of waves seem to be affected by other structures like bone parts and heart.