68 resultados para NEUTRON RADIOGRAPHY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The aim of this study was to assess the occurrence of apical root transportation after the use of Pro Taper Universal rotary files sizes 3 (F3) and 4 (F4). Methods: Instruments were worked to the apex of the original canal, always by the same operator. Digital subtraction radiography images were produced in buccolingual and mesiodistal projections. A total of 25 radiographs were taken from root canals of human maxillary first molars with curvatures varying from 23-31 degrees. Quantitative data were analyzed by intraclass correlation coefficient and Wilcoxon nonparametric test (P = .05). Results: Buccolingual images revealed a significantly higher degree of apical transportation associated with F4 instruments when compared with F3 instruments in relation to the original canal (Wilcoxon test, P = .007). No significant difference was observed in mesiodistal images (P = .492). Conclusions: F3 instruments should be used with care in curved canals, and F4 instruments should be avoided in apical third preparation of curved canals. (J Endod 2010;36:1052-1055)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

All methods to detect experimental loss of bone present technique limitations. The sensitivities of image and histological analyses to detect the effects of teriparatide in rats with bone loss after ovariectomy were evaluated. All methods were qualitatively valid.The standardization of methods to assess bone loss after ovariectomy is crucial to establish the degree of experimental osteoporosis. In general, methods per image or histological techniques are used. To validate these two ways to determine the degree of bone loss in ovariectomized rats, we evaluated the sensitivities of bone densitometry, conventional radiography, and histological analysis of the area occupied by collagen, detecting the effects of teriparatide treatment in the femur of ovariectomized rats with bone loss.Wistar rats were divided into three groups: a control group, in which the animals were only subjected to laparotomy; an ovariectomized group, in which bilateral removal of the ovaries was performed; and an ovariectomized + teriparatide group, in which bilateral removal of the ovaries was performed, and the animals were treated with 3 mu g/100 g/day of teriparatide. Three months following the ovariectomy, bone densitometry, radiographic densitometry, and histological analysis of the area occupied by collagen fibers were carried out in the femur diaphysis.The bone densitometry revealed 11.2% reduction in femur density; in the conventional radiography, the loss of bone mass was 14.5%, and with the histological analysis, a 40.9% reduction in the area occupied by collagen was detected in the femur diaphysis.In conclusion, histological analysis could not be quantitatively compared with the methods of bone densitometry and conventional radiography; however, all of these methods were qualitatively valid for assessing the loss of bone stemming from ovariectomy and the therapeutic effect of teriparatide in the prevention of osteoporosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article a new technique for thermal neutron detection using pyroelectric ceramics is described. The detector system is basically constituted of a PZT (lead zirconate titanate) ceramic attached to an uranium disk. The energy released in the uranium fission gives rise to an electrical signal in the detector which is amplified by a lock-in system. The neutron beam impinging on the uranium disk was modulated with a cadmium chopper. Thermal neutron fluxes within the interval of 103 to 106 n/cm2 s have been detected using a U3O8 pellet with 20% enrichment in 235U. © 1992.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We use the Walecka model to investigate the influence of the charge symmetry breaking ρ0-ω mixing interaction on the neutron-proton self-energy difference in nuclear matter. Using 2mρ〈ρ0|H|ω〉 = -4500 MeV2, and employing the Dirac-Hartree-Fock approximation, we find that the neutron-proton self-energy difference is a decreasing function of the nuclear matter density, and that it has a value of the order of 700 keV at the normal density. The results indicate that the Nolen-Schiffer anomaly might be explained by means of relativistic nuclear models in a similar way as it is explained by means of non-relativistic models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have studied the effects of niobium beam filtration on absorbed doses, on image density and contrast, and on photon spectra with conventional and high-frequency dental x-ray generators. Added niobium reduced entry and superficial absorbed doses in periapical radiography by 9% to 40% with film and digital image receptors, decreased the radiation necessary to produce a given image density on E-speed film and reduced image contrast on D- and E-speed films. As shown by increased half-value layers for aluminum, titanium, and copper and by pulse-height analyses of beam spectra, niobium increased average beam energy by 6% to 19%. Despite the benefits of adding niobium on patient dose reduction and on narrowing the beams' energy spectra, the beam can be overhardened. Adding niobium, therefore, strikes the best balance between radiation dose reduction and beam attenuation, with its risks of increased exposure times, motion blur, and diminished image contrast, when it is used at modest thicknesses (30 μm) and at lower kVp (70) settings. © 1995 Mosby-Year Book, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thin uranium films built on muscovite mica basis and obsidian samples having known ages were irradiated with thermal neutrons at the IPEN/CNEN reactor, São Paulo. Comparing thin film performance with the obsidian one, it was observed that the latter feel a greater neutron fluence. Nominal fluences at the used facility are in agreement with the results obtained analysing the obsidian samples. A probable hypothesis to explain this disagreement, namely, the uranium loss from the thin films, was ruled out. © 1995.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Considering the ferromagnetic screening for the decay of the X-ray neutron star magnetic field in the binary accretion phase, the phase transition of ferromagnetic materials in the crust of neutron star induces the ferromagnetic screening saturation of the accreted crust, which results in the minimum surface magnetic field of the accreting neutron star, about 108 G, if the accreted matter has completely replaced the crust mass of the neutron star. The magnetic field evolution versus accreted mass is given as Bs ∝ ΔM-0.9, and the obtained magnetic field versus spin period relation is consistent with the distribution of the binary X-ray sources and recycled pulsars. The further thermal effect on the magnetic evolution is also studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the equation of state for neutron matter using the Walecka model including quantum corrections for baryons and sigma mesons through a realignment of the vacuum. We next use this equation of state to calculate the radius, mass, and other properties of rotating neutron stars.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two auxiliary methods of diagnosing nasopharyngeal airway obstruction were compared. Cephalometric radiography and nasopharyngeal videoendoscopy were evaluated for efficacy in terms of reproducibility and validity. Thirty orthodontic patients (7 to 12 years of age) seeking otorhinolaryngologic treatment for mouth breathing, or mouth and nose breathing, had nasopharyngeal endoscopy and radiographic examinations performed on the same day. Two otorhinolaryngologists analyzed the results. Nasopharyngeal endoscopy was more reliable in identifying all the obstructive nasopharyngeal processes. Endoscopy obtained kappa index scores of almost perfect agreement for diagnosis of posterior nasal septum deviation, of substantial agreement for anterior nasal septum deviation and lower turbinate hypertrophy, and of moderate agreement for middle turbinate hypertrophy. Lateral cephalometric radiography obtained scores of perfect agreement for imaging hypertrophy of the middle turbinate, of almost perfect agreement for imaging hypertrophy of the posterior portion of the inferior turbinate, and of substantial agreement for imaging hypertrophy of the inferior turbinate. Radiographic diagnoses of hypertrophy of the middle and lower turbinates exhibited high sensitivity and low specificity when compared with diagnoses by nasopharyngeal endoscopy.