55 resultados para Motor nerve conduction velocity
Resumo:
This paper presents a design and construct the system of data acquisition with wireless transmission of some important parameters like motor temperature, motor rotation and velocity of Unesp Racing´s formula car prototype from Universidade Estadual Paulista, Campus Guaratinguetá. This system development presents a contribution for the electrical technical features adding important points in the competition due car´s electric, in addition, enables preventive maintenance and fine adjustment of the car with the data obtained during training and racing
Resumo:
The mechanisms underlying improvement of neuromuscular transmission deficits by glucocorticoids are still a matter of debate despite these compounds have been used for decades in the treatment of autoimmune myasthenic syndromes. Besides their immunosuppressive action, corticosteroids may directly facilitate transmitter release during high-frequency motor nerve activity. This effect coincides with the predominant adenosine A(2A) receptor tonus, which coordinates the interplay with other receptors (e.g. muscarinic) on motor nerve endings to sustain acetylcholine (ACh) release that is required to overcome tetanic neuromuscular depression in myasthenics. Using myographic recordings, measurements of evoked [H-3]ACh release and real-time video microscopy with the FM4-64 fluorescent dye, results show that tonic activation of facilitatory A(2A) receptors by endogenous adenosine accumulated during 50 Hz bursts delivered to the rat phrenic nerve is essential for methylprednisolone (03 mM)-induced transmitter release facilitation, because its effect was prevented by the A(2A) receptor antagonist, ZM 241385 (10 nM). Concurrent activation of the positive feedback loop operated by pirenzepine-sensitive muscarinic M-1 autoreceptors may also play a role, whereas the corticosteroid action is restrained by the activation of co-expressed inhibitory M-2 and Al receptors blocked by methoctramine (0.1 mu M) and DPCPX (2.5 nM), respectively. Inhibition of FM4-64 loading (endocytosis) by methylprednisolone following a brief tetanic stimulus (50 Hz for 5 s) suggests that it may negatively modulate synaptic vesicle turnover, thus increasing the release probability of newly recycled vesicles. Interestingly, bulk endocytosis was rehabilitated when methylprednisolone was co-applied with ZM241385. Data suggest that amplification of neuromuscular transmission by methylprednisolone may involve activation of presynaptic facilitatory adenosine A(2A) receptors by endogenous adenosine leading to synaptic vesicle redistribution. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Summary: Neuropathic pain (NP) is a well-recognized feature of leprosy neuropathy. However, the diagnosis of NP is difficult using only clinical criteria. In the study reported here, by means of conventional nerve conduction studies, the authors sought for an association between long-latency responses and NP complaints in leprosy patients with type 1 and 2 reactions. Of the 27 ulnar nerves of leprosy patients, 18 with type 1 reaction (T1R) and 9 with type 2 reaction (T2R) were followed-up for 6 months before and after steroid treatment. Clinical characteristics of pain complaints and clinical function were assessed, as well as the presence of F- and A-waves of the ulnar nerve using nerve conduction studies. The clinical and the neurophysiologic findings were compared to note positive concordances (presence of NP and A-waves together) and negative concordances (absence of NP and A-waves together) before and after treatment. Both reactions presented a high frequency of A-waves (61.1% in T1R and 66.7% in T2R, P < 0.05) and prolonged F-waves (69.4% in T1R and 65.8% in T2R, P = 0.4). No concordances were seen between pain complaints and F-waves. However, significant concordances between NP and A-waves were observed, although restricted to the T2R group ([chi]2 = 5.65, P = 0.04). After treatment, there was a significant reduction in pain complaints, as well as the presence of F- and A-waves in both groups (P < 0.05 for all comparisons). In conclusion, the presence of A-waves correlates well with pain complaints of neuropathic characteristics in leprosy patients, especially in those with type 2 reaction. Probably, such response shares similar mechanisms with the small-fiber dysfunction seen in these patients with NP, such as demyelination, intraneural edema, and axonal sprouting. Further studies using specific tools for small-fiber assessment are warranted to confirm our findings.
Resumo:
Shoulder arthroscopic surgeries evolve with intense postoperative pain. Several analgesic techniques have been advocated. The aim of this study was to compare suprascapular and axillary nerve blocks in shoulder arthroscopy using the interscalene approach to brachial plexus blockade. According to the technique used, sixty-eight patients were allocated into two groups: interscalene group (IG, n=34) and selective group (SG, n=34), with neurostimulation approach used for both techniques. After appropriate motor response, IG received 30 mL of 0.33% levobupivacaine in 50% enantiomeric excess with adrenalin 1:200,000. After motor response of suprascapular and axillary nerves, SG received 15 mL of the same substance on each nerve. General anesthesia was then administered. Variables assessed were time to perform the blocks, analgesia, opioid consumption, motor block, cardiovascular stability, patient satisfaction and acceptability. Time for interscalene blockade was significantly shorter than for selective blockade. Analgesia was significantly higher in the immediate postoperative period in IG and in the late postoperative period in SG. Morphine consumption was significantly higher in the first hour in SG. Motor block was significantly lower in SG. There was no difference between groups regarding cardiocirculatory stability and patient satisfaction and acceptability. Failure occurred in IG (1) and SG (2). Both techniques are safe, effective, and with the same degree of satisfaction and acceptability. The selective blockade of both nerves showed satisfactory analgesia, with the advantage of providing motor block restricted to the shoulder.
Resumo:
JUSTIFICATIVA E OBJETIVO: Cirurgias artroscópicas do ombro cursam com intensa dor pós-operatória. Diversas técnicas analgésicas têm sido preconizadas. O objetivo deste estudo foi comparar o bloqueio dos nervos supraescapular e axilar nas cirurgias artroscópicas de ombro com a abordagem interescalênica do plexo braquial. MÉTODO: Sessenta e oito pacientes foram alocados em dois grupos de 34, de acordo com a técnica utilizada: grupo interescalênico (GI) e grupo seletivo (GS), sendo ambas as abordagens realizadas com neuroestimulador. No GI, após resposta motora adequada foram injetados 30 mL de levopubivacaína em excesso enantiomérico de 50% a 0,33% com adrenalina 1:200.000. No GS, após resposta motora do nervo supraescapular e axilar, foram injetados 15 mL da mesma substância em cada nervo. em seguida, realizada anestesia geral. Variáveis avaliadas: tempo para realização dos bloqueios, analgesia, consumo de opioide, bloqueio motor, estabilidade cardiocirculatória, satisfação e aceitabilidade pelo paciente. RESULTADOS: Tempo para execução do bloqueio interescalênico foi significativamente menor que para realização do bloqueio seletivo. Analgesia foi significativamente maior no pós-operatório imediato no GI e no pós-operatório tardio no GS. Consumo de morfina foi significativamente maior na primeira hora no GS. Bloqueio motor foi significativamente menor no GS. Estabilidade cardiocirculatória, satisfação e aceitabilidade da técnica pelo paciente não diferiram entre os grupos. Ocorreu uma falha no GI e duas no GS. CONCLUSÕES: Ambas as técnicas são seguras, eficazes com mesmo grau de satisfação e aceitabilidade. O bloqueio seletivo de ambos os nervos apresentou analgesia satisfatória, com a vantagem de proporcionar bloqueio motor restrito ao ombro.
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Superficial nerve injuries are very common during varicose vein surgery. In contrast, deep nerve injuries are rare and reported especially when surgery involves the small saphenous vein (SSV). The deep motor nerves most commonly injured are the tibial nerve and the peroneal nerve, which are directly or indirectly affected by extrinsic compression, stretching, or healing process involvement. In this report, two cases of common fibular nerve injury after SSV stripping are described, including treatment used and patient outcomes. Nerve damage mechanisms, anatomy, and prevention strategies are also discussed. In conclusion, fibular nerve damage may occur during SSV stripping. Preventive measures include careful preoperative ultrasonographic investigation of the anatomy of the vein, determining location of the saphenopopliteal joint, and careful dissection far from fibular nerve and restricted to the popliteal fossa.
Resumo:
Although veins and arteries present similar wall structures, there are differences which may be relevant in peripheral nerve reconstruction. Inside-out vein grafts (IOVG) have been satisfactorily used to repair both motor and sensitive nerves. However, the inside-out artery graft (IOAG) is a new technique and not fully investigated. Our study presents comparative morphological data on nerve regeneration achieved with IOVG and IOAG in the repair of Wistar rat sciatic nerves. Jugular veins and aorta arteries were harvested from donor animals and used inside-out to bridge a 10-mm gap. Animals were sacrificed at 10 weeks to evaluate nerve regeneration. Both techniques presented great variability in nervous tissue, though some animals showed satisfactory results. Different intensities of scarring processes might have interfered with nerve regeneration. Although IOVG and IOAG techniques showed similar morphometric results, in general, IOVG presented a closer-to-normal nerve organization than IOAG.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
CAUDA equina syndrome (CES) has long been recognized as a rare complication of spinal anesthesia.(1) CES has been described after administration of spinal anesthetics with lidocaine(2) and bupivacaine.(3) In 1991,(4) CES was reported after continuous spinal anesthesia with 1% tetracaine. In 1980, at our university hospital, six adult female patients underwent perineal gynecologic surgery using a spinal anesthetic of 2 ml tetracaine, 1.2%, in 10% glucose. The concentration of the injected tetracaine was unknown by the anesthetists. In all cases, lumbar puncture was performed at the L3-L4 interspace with a disposable spinal needle while the patients were in the sitting position. CES was first diagnosed 72 h or later postoperatively; previous diagnosis was not possible because patients had an indwelling urethral catheter. The diagnosis of CES was confirmed in all patients. During the past year, after institutional approval and informed consent, clinical, magnetic resonance imaging, electromyographic examinations, and conduction studies were performed in three of the above patients. Examinations were not possible on the other three patients because one had recently died, another could not be located, and the third refused to participate. T1 and T2 magnetic resonance image readings were obtained with Gadolinium contrast from a 0.5 Tesla General Electric apparatus (General Electric, Tokyo, Japan). Bilateral sensory and motor conduction studies of the sciatic nerve branches were obtained using a two-channel Nihon-Kohden Neuropack 2 (Nihom-Kohden Corporation, Tokyo, Japan). Electromyography was performed in accordance with conventional techniques.(5,6)
Resumo:
Despite the frequent use of stepping motors in robotics, automation, and a variety of precision instruments, they can hardly be found in rotational viscometers. This paper proposes the use of a stepping motor to drive a conventional constant-shear-rate laboratory rotational viscometer to avoid the use of velocity sensor and gearbox and, thus, simplify the instrument design. To investigate this driving technique, a commercial rotating viscometer has been adapted to be driven by a bipolar stepping motor, which is controlled via a personal computer. Special circuitry has been added to microstep the stepping motor at selectable step sizes and to condition the torque signal. Tests have been carried out using the prototype to produce flow curves for two standard Newtonian fluids (920 and 12 560 mPa (.) s, both at 25 degrees C). The flow curves have been obtained by employing several distinct microstep sizes within the shear rate range of 50-500 s(-1). The results indicate the feasibility of the proposed driving technique.
Resumo:
Nerve regeneration in a sensory nerve was obtained by the application of different techniques: inside-out vein graft (IOVG group) and standard vein graft (SVG group). These techniques provide a good microenvironment for axon regeneration in motor nerves, but their efficiency for regeneration of sensory nerves is controversial. The saphenous nerve was sectioned and repaired by the inside-out and standard vein graft techniques in rats. After 4, 12, and 20 weeks the graft and the distal stump were observed under electron microscopy. In each studied period, the pattern, diameters, and thickness of the myelin sheaths of the regenerated axons were measured in the graft and distal stump. A comparative study about the regenerated nerve fibers by these two different techniques was performed. Regenerated nerve fibers were prominent in both vein grafts 4 weeks after the surgical procedures. On the other hand, in the distal stump, regenerated nerve fibers were observed only from 12 weeks. In both inside-out vein graft and standard vein graft statistical difference was not observed about the diameters and thickness of the myelinated fibers after 20 weeks. On the other hand, the inside-out group had greater regenerated axon number when compared to the standard group. There is a capillary invasion in both graft and distal stump, especially in the IOVG group. The regenerated axons follow these capillaries all the time like satellite microfascicles. After 20 weeks, the diameters of regenerated fibers repaired by the standard vein graft technique were closer to the normal fibers compared to the inside-out vein graft. On the other hand, the pattern of these regenerated axons was better in the IOVG group.
Resumo:
The ulnar-to-median nerve anastomosis in the forearm is a very rare occurrence, not mentioned in many anatomical text books. We found only 4 cases cited in medical literature. Here we describe 2 new cases, for which diagnosis was suspected when the compound muscle action potential of the abductor pollicis brevis muscle (APB), obtained by maximal stimulation of the median nerve at the elbow, was lower than that obtained at the wrist. The diagnosis was confirmed by stimulation of the ulnar nerve at the elbow, which evoked a compound muscle action potential of the APB with a clear negative initial deflection without volume-conducted potential.
Resumo:
Introduction: Children with Moebius syndrome may present paralysis of cranial nerves III, IV, V, VI, VII, VIII, IX, X and XII, compromising motor and sensorial functions. Hands and feet defects (syndactyly, equinovarus and arthrogryposis) are frequently associated. These manifestations can be attributed to the use of misoprostol during pregnancy to induce abortion. Study design: Clinical prospective. Aim: To evaluate the main clinical manifestations, hearing acuity and possible etiologic factors in children with Moebius syndrome. Material and method: The children were submitted to clinical, otolaryngological and hearing acuity assessment. Hearing acuity was evaluated through behavioral tests, pure tone audiometry, tympanometry and auditory brainstem response (ABR). We investigated possible etiologic factors. Results: Three boys and two girls were evaluated. The main manifestations were: facial paralysis, paralysis of masseter muscle, defects in dental occlusion, retraction of tympanic membrane, equinovarus, oblique palpebral fissure and tongue atrophy. Conductive hearing loss was detected in three children and sensorineural hearing loss in one child. The use of misoprostol during pregnancy was reported by four mothers. Conclusions: The children with Moebius syndrome evaluated in the present study manifested palsies of various cranial nerves, especially V, VII and XII nerves, responsible for motor and sensorial alterations. Inadequate eustachian tube function associated to conductive hearing loss was frequent. The use of misoprostol during pregnancy was reported by the mothers and it was considered a possible etiologic factor.