43 resultados para Meteorological instruments


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Ozone has been used as an alternative method for the decontamination of water, food, equipment and instruments. The objective of this study was to evaluate the antimicrobial effects of ozonated water on the sanitization of dental instruments that were contaminated by Escherichia coli, Staphylococcus aureus, Candida albicans and the spores of Bacillus atrophaeus. Methods: A total of one hundred and twenty standardized samples of diamond dental burs were experimentally contaminated with E. coli (ATCC 25922), S. aureus (ATCC 6538) and C. albicans (ATCC 18804) and the spores of B. atrophaeus (ATCC 6633) for 30min. After the contamination, the samples were exposed to ozonated water (10mg/L O3) for 10 or 30min. The control group was composed of samples that were exposed to distilled water for 30min. After the exposure to the ozonated water, 0.1mL aliquots were seeded onto BHI agar to count the colony-forming units per milliliter (CFU/mL) of E. coli, S. aureus, and B. atrophaeus. Sabouraud dextrose agar was used to count the CFU/mL of C. albicans. The results were subjected to an analysis of variance and the Tukey test. Results: For all of the microorganisms studied, the ozonated water reduced the number of CFU/mL after 10 and 30. min of sanitization, and this microbial reduction was dependent on the duration of the exposure to the ozonated water. E. coli exhibited the greatest reduction in CFU/mL (2.72-3.78. log) followed by S. aureus (2.14-3.19. log), C. albicans (1.44-2.14. log) and the spores of B. atrophaeus (1.01-1.98. log). Conclusion: The ozonated water was effective in reducing the CFU of E. coli, S. aureus, C. albicans and B. atrophaeus spores, suggesting that ozonated water can be used for the sanitization of dental instruments. © 2012 King Saud Bin Abdulaziz University for Health Sciences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Ciência do Solo) - FCAV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Ciência do Solo) - FCAV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O experimento foi realizado na área experimental do Departamento de Engenharia Rural da Faculdade de Ciências Agronômicas – Unesp/Botucatu, Estado de São Paulo, em duas estufas dispostas em diferentes orientações geográficas, Leste/Oeste e Norte/Sul. A alface (Lactuva sativa L.) cv. Elisa foi cultivada em ambas estufas, sendo semeada em 05/05/99, transplantada em 29/05/99 e colhida em 31/06/99. Utilizou-se tensiômetros para monitorar o potencial de água no solo para realizar o manejo do sistema de irrigação por gotejamento. Microevaporímetros eqüidistantes de 3 m e colocados em 3 alturas, 0.50, 1.00 e 1.50 m, termohigrógrafos e tanques Classe “A” foram instalados nas duas estufas. Através de análise geoestatística, não se observou dependência espacial nem variabilidade espacial da evaporação nas duas estufas. Entretanto, a altura dos evaporímetros apresentou diferenças significativas: a evaporação à altura de 1.50 foi menor que nas outras duas.As médias de temperatura, umidade relativa e déficit de pressão de vapor do arnão diferiram estatisticamente entre as estufas e o ambiente externo. Os valores médios de evaporação de água no tanque Classe A instalado fora das estufas diferiram estatisticamente quando comparados com os instalados no interior das estufas, porém, entre as orientações não se constatou diferença significativa. Pôde-se verificar que não houve diferença significativa das características agronômicas da alface em ambas orientações estudadas. No entanto, houve diferença significativa para essas características entre os canteiros no interior das mesmas, havendo variância espacial para os dados de matéria fresca apenas na estufa N/S.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The best irrigation management depends on accurate estimation of reference evapotranspiration (ET0) and then selection of the appropriate crop coefficient for each phenological stage. However, the evaluation of water productivity on a large scale can be done by using actual evapotranspiration (ETa), determined by coupling agrometeorological and remote sensing data. This paper describes methodologies used for estimating ETa for 20 centerpivots using three different approaches: the traditional FAO crop coefficient (K-c) method and two remote sensing algorithms, one called SEBAL and other named TEIXEIRA. The methods were applied to one Landsat 5 Thematic Mapper image acquired in July 2010 over the Northwest portion of the Sao Paulo State, Brazil. The corn, bean and sugar cane crops are grown under center pivot sprinkler irrigation. ET0 was calculated by the Penman-Monteith method with data from one automated weather station close to the study site. The results showed that for the crops at effective full cover, SEBAL and TEIXEIRA's methods agreed well comparing with the traditional method. However, both remote sensing methods overestimated ETa according to the degree of exposed soil, with the TEIXEIRA method presenting closer ETa values with those resulted from the traditional FAO K-c method. This study showed that remote sensing algorithms can be useful tools for monitoring and establishing realistic K-c values to further determine ETa on a large scale. However, several images during the growing seasons must be used to establish the necessary adjustments to the traditional FAO crop coefficient method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The wide territorial extension of Brazil derails the installation and maintenance of instruments for measuring solar radiation, which makes necessary the development and application of models that are able to estimate reliable and sufficient data for many different activities that use such data. And these, in most cases, are estimated from the Ångström equation. Based on this model, this project aimed to estimate the global solar radiation at Presidente Prudente-SP, Brazil, using daily data from 1999 to 2007. The solar radiation data have been extracted from the paper tapes of actinograph bi-metallic (Robitsch) daily records at the meteorological station in the Faculty of Science and Technology, UNESP. These tapes were scanned, resulting in digital images with x and y coordinates pairs (x = time; y = solar radiation, cal/min.cm²). The daily global solar radiation is the area under the curve of the image. This value has been calculated by computer algorithms. After the acquisition and calculation of the values needed to develop the Ångström equation have been determined the constants a and b, using linear regression between the values of Rg/R0 (solar radiation/solar radiation on a horizontal surface at the top of atmosphere), as ordered, and n/N (number of hours of sunshine/day length in hours) as abscissa. The slope of the line will be the constant b and the linear coefficient, the constant a. The estimated results were compared to the observed using the Kolmogorov-Smirnov test, realizing that the models can be accepted. So, the equation to aim the solar global radiation is: Rg = R0 (0,2662+0,3592 n/N)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the increase of the cervical area and dentin thickness in mesial and distal walls of the mesial canals from mandibular molars after the use of LA Axxess (LA), CP Drill (CP) and Gates-Glidden (GG) rotary instruments. Material and Methods: Sixty root canals from thirty mandibular first molar were sectioned 3 mm below the cement-enamel junction, divided in 3 groups (n = 20 root canals, each) according to rotary instrument used, and the cervical images were captured before and after pre-enlargement instrumentation. The increase of the instrumented cervical area (mm2) and the dentin removal thickness (mm), at mesial and distal walls were calculated using Image tools software, by comparison of images. Data were analyzed by ANOVA and Tukey tests (p=0.05). Results: All rotary instruments promoted thickness reduction in dentin walls. In mesial wall, all rotary instruments promoted similar thickness reduction of dentinal wall and did not differ from each other (p>0.05). In distal wall, LA Axxess instrument promoted higher dentin thickness reduction than other groups (p<0.05). The three rotary instruments promoted different increase at the instrumented cervical area (p<0.05), LA promoted the highest increase area and GG and CP presented similar results. Conclusion: LA 20/0.06 promoted the highest thickness reduction in distal wall and increase of cervical area of root canal. On the other hand, CP was the safest instrument, with lower dentin removal of distal wall and similar increased area to GG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: This clinical report presents a new method for retrieving separated instruments from the root canal with minimally invasive procedures. Background: The presence of separated instrument in root canal may interfere in the endodontic treatment prognosis. There are several recommended methods to retrieve separated instruments, but some are difficult in clinically practice. Case report: This study describes two cases of separated instrument removal from the root canal using a stainless-steel prepared needle associated with a K-file. Case 1 presented a fractured gutta-percha condenser within the mandibular second premolar, it was separated during incorrect intracanal medication calcium hydroxide placement. Case 2 had a fractured sewing needle within the upper central incisor that the patient used to remove food debris from the root canal. After cervical preparation, the fractured instruments were fitted inside a prepared needle and then an endodontic instrument (#25 K-file) was adapted with clockwise turning motion between the needle inner wall and the fragment. Conclusion: The endodontic or atypical nonendodontic separated instrument may be easily pull on of the root canal using a single and low cost device. Clinical significance: The methods for retrieving separated instruments from root canal are difficult and destructive procedures. The present case describes a simple method to solve this problem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To describe the surgical technique and initial experience with a single-port retroperitoneal renal biopsy (SPRRB).Materials and Methods: Between January and April 2013, five children underwent SPRRB in our hospital. A single 1.5 cm incision was performed under the 12th rib at mid-axillary line, and an 11 mm trocar was inserted. A nephroscope was used to identify the kidney and dissect the perirenal fat. After lower pole exposure, a laparoscopic biopsy forceps was introduced through the nephroscope working channel to collect a renal tissue sample.Results: SPRRB was successfully performed in five children. The mean operative time was 32 minutes, and mean estimated blood loss was less than 10 mL. The hospital stay of all patients was two days because they were discharged in the second postoperative day, after remaining at strict bed rest for 24 hours after the procedure. The average number of glomeruli present in the specimen was 31.Conclusion: SPRRB is a simple, safe and reliable alternative to open and videolaparoscopic approaches to surgical renal biopsy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study is an analytical review of the methodology used in studies of efficacy of screening instruments to detect harmful use/ alcohol dependence according to the gender in population surveys. Systematic review of bibliography was done, using data from Web of Science, Pubmed and PsycInfo. Population studies were included without date range, in English, Spanish or Portuguese languages, with sample of adults, evaluating psychometric characteristics of any alcohol screening instrument, whereas studies in special population or under treatment as well as prevalence of alcohol consumption were excluded. Thirteen studies were selected to be included in the present review. According to the studies, the instruments that presented a better performance among men were AUDIT and its derivatives (6 studies) and CAGE (2 studies), whereas among women, AUDIT and its derivatives (7 studies), followed by CAGE (3 studies). The increase of consumption and problems related to alcohol use and its implications for public health indicate the need and urgency for adequacy of screening instruments to differences of gender in general population. The population surveys in the area are scarce. Furthermore, the found studies present heterogeneous methodology which makes accurate comparisons difficult.