262 resultados para Mandibular reconstruction
Resumo:
AIM: To evaluate the host response of the gel and porous polyethylene implants in anophthalmic cavities using the B scan ultrasound.METHODS: Thirty-six white rabbits underwent unilateral enucleation with placement of gel or porous polyethylene spheres implants. The animals were submitted to clinical examination weekly and to ultrasound evaluation on 30, 60 and 90 days after surgery.RESULTS: All rabbits with gel polyethylene spheres, except one, showed implant extrusion probably because the gel spheres have hydrated and increased in volume. The B ultrasound of the gel polyethylene implant did not show vessels inside during the following period. Five animals (27.8%) with porous polyethylene spheres presented implant extrusion after 30 days of surgery. According to B ultrasound, the porous polyethylene implant showed irregular and heterogeneous architecture and reflective peaks similar to vascularized tissues.CONCLUSION: More studies are required to determine the ideal volume of gel polyethylene implant necessary to correct the diminished orbital content in the anophthalmic cavity. The B ultrasound effectiveness showed in this study for anophthalmic socket implants evaluation provides useful information for further in vivo studies and might substitute expensive methods of implants vascularization evaluation,
Resumo:
A 59-year-old white man developed a ventral ulcer with irregular limits in the middle portion of the penis. The result of the pathologic analysis was compatible with invasive squamous cell urethral carcinoma. A total penectomy was performed. In these cases, the usually recommended urinary diversion is perineal urethrostomy. However, due to the specifications of the case, perineal urethrostomy could not be performed. The literature did not offer any other alternative for patients with this same condition. Therefore, a urethral reconstruction using a groin skin flap had to be performed. Copyright (C) 2004 S. Karger AG, Basel.
Resumo:
Descreve-se um surto de abscesso mandibular em ovelhas da raça Bergamácia no município de Botucatu, estado de São Paulo. do rebanho de 120 animais, 35 apresentaram aumento de volume mandibular com a presença de nódulos únicos, de consistência pétrea, de diferentes tamanhos, fistulados ou não e sem indicativos de inflamação dos tecidos moles adjacentes. Os animais eram criados em pasto de Panicum maximum cv. Tanzânia com água e sal mineral ad libitum e everminados, via oral, com pistolas dosificadoras. O material para diagnóstico microbiológico e antibiograma foi coletado de cinco animais acometidos, por punção e aspiração dos nódulos. Dos 35 animais acometidos, 19 foram submetidos ao exame radiográfico, um ao exame tomográfico e outro à biópsia óssea da região submandibular. O único ovino que morreu, encontrava-se em estado de caquexia provavelmente devido à localização do aumento de volume que afetou a implantação dos dentes molares daquela região impedindo a apreensão e mastigação adequadas levando a perda da condição corporal e morte. Ao exame necroscópico, observaram-se áreas de necrose caseosa na mandíbula direita de onde isolou-se Pseudomonas aeruginosa. O tratamento utilizado foi baseado na aplicação de iodeto de sódio a 10% por via intramuscular e antibioticoterapia segundo antibiograma com enrofloxacina por via intramuscular, porém com pouca eficácia. Diante do quadro clínico, dos dados de anamnese, da localização das lesões no tecido ósseo mandibular, do resultado do cultivo microbiológico, das alterações radiográficas e tomográficas foi feito o diagnóstico de abscesso mandibular causado por Pseudomonas aeruginosa.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objetivou-se, com este experimento, avaliar a ação da ropivacaína a 0,5% no bloqueio do nervo alveolar mandibular de gatos. Vinte gatos adultos, sem raça definida, machos ou fêmeas, receberam clorpromazina (1,0mg kg-1, VO) e propofol (3,0mg kg-1, IV). Ropivacaína a 0,5% foi administrada com uma agulha 13x3,8 em forma de L, inserida no ângulo da mandíbula direita, aproximadamente 1,0cm rostral ao processo angular e 0,5cm dorsal à superfície medial do ramo da mandíbula, a fim de depositá-la próximo ao nervo alveolar mandibular, no forame mandibular. As freqüências cardíaca e respiratória foram mensuradas antes da administração da clorpromazina, 20 minutos após administração desta (T0), 20 minutos após o bloqueio do nervo alveolar mandibular com ropivacaína (T20) e, em intervalos de 20 minutos, até a volta da sensibilidade na região anestesiada. Observou-se o período de latência e a duração da anestesia por meio do pinçamento da pele e gengiva da região lateral direita da mandíbula. Encontrou-se início da anestesia após 22 minutos, com duração de 164,25 minutos. Os parâmetros de freqüência cardíaca e freqüência respiratória tiveram alterações, porém sem significado clínico para a espécie. A ropivacaína a 0,5% anestesia a região dos dentes pré-molares, molares, caninos, incisivos, pele e mucosa oral e lábio inferior, sem causar efeitos colaterais.
Resumo:
This study aimed to develop a plate to treat fractures of the mandibular body in dogs and to validate the project using finite elements and biomechanical essays. Mandible prototypes were produced with 10 oblique ventrorostral fractures (favorable) and 10 oblique ventrocaudal fractures (unfavorable). Three groups were established for each fracture type. Osteosynthesis with a pure titanium plate of double-arch geometry and blocked monocortical screws offree angulanon were used. The mechanical resistance of the prototype with unfavorable fracture was lower than that of the fcworable fracture. In both fractures, the deflection increased and the relative stiffness decreased proportionally to the diminishing screw number The finite element analysis validated this plate study, since the maximum tension concentration observed on the plate was lower than the resistance limit tension admitted by the titanium. In conclusion, the double-arch geometry plate fixed with blocked monocortical screws has sufficient resistance to stabilize oblique,fractures, without compromising mandibular dental or neurovascular structures. J Vet Dent 24 (7); 212 - 221, 2010
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Odontogenic myxomas are considered to be a benign odontogenic tumor with locally aggressive behavior. Because these neoplasms are rare in the oral cavity, the possible surgical management can be quite variable. Literature recommendation can vary from simple curettage and peripheral ostectomy to segmental resection. The authors report a case of a 20-year-old patient with an odontogenic myxoma tumor located in the left mandibular angle, ascending ramus, and mandibular symphysis. It was treated by radical resection followed by titanium reconstruction with condylar prosthesis, which allowed rapid return of function with improvement in quality of life and restoration of cosmetic and functional deficits. The lesion did not recur after surgical procedure.
Resumo:
This study verified the resistance to displacement of six miniplate fixation methods after sagittal split osteotomy (SSO). SSO was performed in 30 polyurethane synthetic mandible replicas. The distal segments were advanced (4 mm) and specimens were grouped according to the fixation method: four-hole standard miniplate; four-hole locking miniplate; six-hole standard miniplate; six-hole locking miniplate; six-hole standard sagittal miniplate; six-hole locking sagittal miniplate. Biomechanical evaluation was performed by applying compression loads to three points on the second molar region, using an Instron universal testing machine until a 3 mm displacement of the segments occurred. Compression loads able to produce 3 mm displacement were recorded in kN and subjected to analysis of variance (P < 0.01) and Tukey's tests for comparison between groups (P < 0.05). The locking sagittal miniplate showed higher resistance to displacement than the regular four- and six-hole locking and standard miniplates. No significant differences were observed between the locking sagittal miniplate and the regular sagittal or the four-hole locking miniplates. Two of the three groups with the best results had locking plate fixation methods. Fixation of SSO with a single miniplate is better accomplished using six-hole locking sagittal miniplates, six-hole standard sagittal miniplates, or four-hole locking miniplates; these methods are more resistant to displacement.
Resumo:
Traumatic injuries treatment of the fronto-naso-orbito-ethmoidal region has been one of the most challenging treatments within maxillofacial surgery, particularly of extensive orbital defects, very common in this type of pathologic condition. A 48-year-old man involved in a car collision presented an extensive bilateral fracture of the orbit medial wall, nasal bones, the nasal septum, and the frontal anterior table. The clinical and tomographic findings concluded the diagnosis of a maxilla and fronto-naso-orbito-ethmoidal fracture. Among the variety of biomaterials, the titanium mesh was elected because of the extension and magnitude of the bone defect, obtaining this way esthetic and functional results with better prognosis.
Resumo:
This article reports the 20-month clinical outcome of the use of 4 zygomatic implants with immediate occlusal loading and reverse planning for the retreatment of atrophic edentulous maxilla after failed rehabilitation with autogenous bone graft reconstruction and maxillary implants. The intraoral clinical examination revealed mispositioned and loosened implants underneath a maxillary complete denture. The panoramic radiograph showed 6 maxillary implants. One implant was displaced into the right maxillary sinus, and the implant anchored in the region of tooth 21 was fractured. The other implants presented peri-implant bone loss. The implants anchored in the regions of teeth 21 to 23 and 11 to 13 were first removed. After 2 months, the reverse planning started with placement of 4 zygomatic fixtures, removal of the implants migrated into the sinus cavity and anchored in the region of tooth 17, and installation of a fixed denture. After 20 months of follow-up, no painful symptoms, peri-implant inflammation or infection, implant instability, or bone resorption was observed. The outcomes of this case confirm that the zygoma can offer a predictable anchorage and support function for a fixed denture in severely resorbed maxillae.
Resumo:
Objective: The objective of the study was to analyze 2-flap designs for surgical extraction of third molar, evaluating the periodontal status of the second lower molar.Study Design: Forty-five lower third molars were extracted from 24 patients. In 23 teeth, a vertical incision to the mandibular ramus was used (technique A), whereas 22 teeth were submitted to classic L-shaped flap (technique B) with controls at 60 and 90 days postoperatively.Results: Pearson correlation coefficient analysis showed a significant correlation only between immediate preoperative probing depth variables from techniques A and B in the studied surfaces. Statistical significances in the preoperative (vestibular) and postoperative day 60 (distovestibular and vestibular) were noted. In contrast, Student t-test showed no statistical difference in probing depths between preoperative and postoperative values, as well as no statistically significant difference regarding the type of incision alone.Conclusions: Technique A allowed a less traumatic surgery, guaranteeing a more comfortable postoperative period.
Resumo:
Purpose: The aim of this study was to evaluate the bone repair process in the maxillary sinus in monkeys treated with high-density porous polyethylene (Medpor)Methods: Four capuchin monkeys (Cebus apella) were submitted to bilateral horizontal osteotomies in the anterior wall of the maxillary sinus and divided into 2 groups: control group, left side with no implants, and porous polyethylene group, right side with Medpor. After a period of 145 days after implant placement, the maxillae were removed for histologic and histometric analyses.Results: Bone repair in osteotomized areas took place by connective tissue in 58.5% and 58.7% in the control group and the porous polyethylene group, respectively. In the contact surface with Medpor, bone repair occurred in 41.3%.Conclusions: Medpor was not reabsorbed within the period of this study and allowed bone repair surrounding it. The porous polyethylene constitutes a feasible alternative for bone defect reconstruction.