49 resultados para MITRAL VALVE STENOSIS
Resumo:
Objectives: To analyze the potential contribution of contractility state and ventricular geometry to the development of heart failure in rats with aortic stenosis.Methods: Rats were divided into three groups: compensated aortic stenosis (AS, n = 11), heart failure AS (n = 12) and control rats (C, n = 13).Results: After 21 weeks, failing AS rats presented higher systolic (C = 36.6 +/- 3.1, AS-78.6 +/- 4.8*, failing AS = 104.6 +/- 7.8*) and diastolic meridian stress (C = 6.9 +/- 0.4, AS = 20.1 +/- 1.1*, failing AS = 43.2 +/- 3.2*(dagger)), hydroxyproline (C = 3.6 +/- 0.7 mg/g, AS = 6.6 +/- 0.6* mg/g, failing AS = 9.2 +/- 1.4*(dagger) mg/g) and cross-sectional area (C = 338 +/- 25 mu m(2), AS = 451 +/- 32* mu m(2), failing AS = 508 +/- 36*(dagger) mu m(2)), in comparison with control and compensated AS animals (*p < 0.05 vs. control, (dagger)p < 0.05 vs. AS). In the isometric contraction study, considering the time from peak tension to 50% relaxation (RT50), the relative variation responses, following post-rest contraction and increase in Ca2+ concentration, were higher in failing AS than compensated AS animals. In contrast, following post-rest contraction, compensated AS group presented higher values of the peak developed tension (DT) than failing AS group. Following beta-adrenergic stimulation, control animals presented higher values of +dT/dt and -dT/dt than AS animals. In addition, failing AS animals presented higher TPT values than compensated AS animals.Conclusion: Myocardial contractile dysfunction contributes to the development of heart failure in rats with aortic stenosis. (c) 2006 Elsevier B.V.. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective. To report a case of cardiac arrhythmia related to a low dose of endovenous lanatoside C. Case report. A 23-year-old pregnant woman with mitral regurgitation complicated with preeclampsia and pulmonary edema presented 2 episodes of atrial tachycardia induced by a intravenous digitalis (2 mg, IV and 1 mg, IV, respectively). Conclusion. This case calls attention to the need for further studies analysing the security of digoxin use in preeclampsia.
Resumo:
CONTEXTO: Válvula de uretra posterior (VUP) é uma conhecida malformação congênita urinária, geralmente diagnosticada em exames ultra-sonográficos pré-natais ou ao nascimento. Raramente, esta doença pode ser encontrada em adolescentes e em adultos. RELATO DE CASOS: Este artigo mostra dois casos de VUP, encontrados em um adolescente e em um adulto. Ambos apresentavam sinais clínicos de infecção do trato urinário e sintomas obstrutivos infravesicais. Os diagnósticos foram realizados por uretrocistografia miccional e uretrocistoscopia. Fulguração endoscópica das válvulas foi o tratamento de escolha para ambos os casos. O acompanhamento demonstrou melhora importante dos sintomas após o tratamento.
Resumo:
In this paper the performances of different cutting fluids and grinding wheel types were analysed in the grinding of SAE HVN-3 workpieces. The resulting residual stress, wheel wear and roughness were evaluated. The influence of the cutting fluid jet velocity v(j) was also analysed. As a conclusion, the lubrication ability seems to be the governing factor in the cutting fluid performance. The use of CBN wheels can significantly reduce the thermal damage in grinding, leading to compressive residual stresses. The CBN wheel and the cutting oil give an optimum combination for performing this grinding operation.
Resumo:
Atherosclerotic renal artery stenosis (RAS) and coronary artery disease (CAD) arise from the same multiple risk factors. The purpose of this study was to assess the frequency of previously undiagnosed CAD in patients with angiographically confirmed RAS, by conducting coronary arteriography in the same setting. of 57 consecutive patients referred for renal arteriography on clinical grounds during a 14-month period, 28 had no RAS and 6 had RAS, but previously documented CAD. of the remainder 23 patients. 17 (74%; CI 56%-92%) had both RAS and CAD (7 single vessel, 4 two-vessel, and 7 multivessel disease). The clinical characteristics, such as age, blood pressure (BP) levels, signs of heart failure, were no different between those with and without CAD, although the 4 diabetic patients, the 4 patients with fundoscopic findings of grade III retinopathy, 11 of 14 with peripheral arterial disease, and 7 of 8 patients with prior stroke belonged in the CAD group. None developed complications as a result of the two consecutive procedures. The data suggest that in patients with RAS the frequency of silent CAD is high and cannot be predicted on clinical grounds alone, therefore coronary angiography should be routinely recommended in the same setting.
Resumo:
The aim of this work is to characterize a metallic slurry (Al-4.5%Cu) flow during thixoforming of an automotive valve. The necessary globular structure was obtained by first inoculating the alloy with TIBAL (5%Ti, 1%B, Al - rest) at 750.0°C, and then reheating to a state between liquidus and solidus prior to thixoforming. Two metallic slurries, with a solid phase of approximately 86.1 and 78.2 percent, were used to generate different experimental flow patterns during the thixoforming process. The flow of the material into the die was observed for total, and partial displacement (2.7, 5.4, 7.5mm) of the punch. The first displacement shows formation of the valve rod. The patterns at each step of displacement of the punch were preserved by quenching in water, thus revealing the profile of the die fill and microstructural evolution. Degeneration of the globular phase was observed along the piece thixoextruded. Thixoextrusion forces versus time curves were generated for partial and full displacement of the punch. Porosity was visible along the billet prior to thixoforming. However, some areas show that the porosity gradually decreased to zero as the thixoextrusion pressure increased. Turbulent, transient and laminar flow are analyzed in this work.
Resumo:
Caustic ingestion is a leading cause of esophageal stenosis in children. Herein we report four cases using mitomycin C (MMC), a drug that inhibits cell division, protein synthesis and fibroblast proliferation and has been used as an adjuvant therapy for caustic esophageal stenosis that is recalcitrant to conventional dilation techniques. A retrospective chart review was performed on four pediatric patients with severe, recurrent esophageal stricture after caustic ingestion. The patients had required six to 20 esophageal dilations over a 4-16-month period before MMC application. MMC was applied after an endoscopic dilation on saturated pledgets at a dose of 0.1 mg/mL for 2 min in the area where the strictures had been lyzed. From the four children treated with MMC, two have been asymptomatic for 16 and 20 months and two still require esophageal dilation, however, at longer intervals. All patients have shown satisfactory weight gain with food intake exclusively per oral. Although further studies are required, there is strong evidence that MMC is a safe and effective adjuvant therapy in the treatment of esophageal caustic stenosis. © 2008 The Authors.
Resumo:
This paper proposes a straightforward compromising method to determine the output power of all committed units during the scheduling time horizon. Unlike the conventional methods that work based on a constant pollution control cost (CPCC), this method works based on the system topology such as demand, minimum cost and minimum output emission of the system. In order to have a meaningful compromise between costs and emission in economic and emission dispatch (EED) problem, a flexible pollution control cost (FPCC) is proposed. Also a dynamic economic emission dispatch (DEED) approach is considered where the ramping constraints couple the scheduling hours; the inclusion of valve-point effect makes the DEED modeling more practical. The validity and effectiveness of the unproblematic FPCC approach is verified through an IEEE 30-bus test system with 6 unit for the 6-hour scheduling horizon. © 2013 IEEE.