248 resultados para Loss Determination in Microsphere Resonators


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the construction of an electrode of the second kind, Pt\Hg\Hg-2(Bzt)(2)\graphite, sensitive to benzoate ion (Bzt). The electrode provides a near-Nernstian response (-58.19 mV/decade at 25 degrees C) to benzoate ion in the concentration range 1.11 x 10(-1) to 5.00 x 10(-4) M at pH 7.0 and ionic strength 0.500-3.00M, adjusted with NaClO4. The electrode is easily constructed, shows a fast response time, is low in cost, has excellent response stability, and has a lifetime greater than 24 months. which is much longer than those earlier reported for other systems. A further salient feature of the electrode is that perchlorate does not interfere in its response, which may be advantageous in the analysis of perchloric acid-treated samples. It was applied to the determination of sodium benzoate in some commercial expectorating medicinal syrups using the standard additions method. The results obtained by the proposed procedure compare very favorably with those obtained through the reference method recommended by the United States Pharmacopeia. (C) 1998 Academic Press.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Screen-printed carbon electrode (SPCE) modified with poly-L-histidine film can be successfully applied for chromium(VI) determination based on its pre-concentration. Optimum adherence and stability of the POIY-L-histidine film was obtained by direct addition of PH solution 1% (w/v) on the electrode surface, followed by heating at 80 degrees C during 5 min. Linear response range, sensitivity and limit of detection were 0. 1-150 [mu mol L-1, 4. 13 LA mu mol L` and 0.046 mu mol L-1. The repeatability of the proposed sensor, evaluated in terms of relative standard deviation, was measured as 3.2% for 10 experiments in 40 mu mol L-1 using the same electrode and 4.0% using screen-printed electrode as disposable sensor, respectively. The voltammetric sensor was applied to determination of Cr(VI) and indirect determination of Cr(III) in wastewater samples previously treated by a leather dyeing industry and the average recovery for these samples was around 97%. (C) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Arsenic and germanium have been evaluated as internal standards to minimize matrix effects on the direct determination of selenium in milk by graphite furnace atomic absorption spectrometry (GFAAS) using tubes with integrated platform, pre-treated with W together with I'd as chemical modifier. The efficiency of As and Ge as internal standards for 25 mu g L-1 Se plus 500 mu g (L)-1 As or Ge in diluted (1 + 9 v/v) milk plus 1.0% (v/v) HNO3 was evaluated by means of correlation graphs plotted from the normalized absorbance signals (n = 20) of internal standard (axis gamma) versus analyte (axis x). The equations that describe the linear regression were: A(As)= - 0.004 +/- 0.019 +/- 1.02 + 0.019 A(Se) (r=0.9967 +/- 0.005); A(Ge)= - 0.0 17 +/- 0.015 + 1.01 +/- 0.015 A(Se) (r = 0.9978 +/- 0.004). Samples and reference solutions were automatically spiked with 500 mu g L-1 Ge or As and 1.0% (v/v) HNO3 by the autosampler. For 20 mu L of aqueous standard solutions, analytical curves in the 5.00-40.0 mu g L-1 Se range were established using the ratio of Se absorbance to internal standard absorbance (A(Se)A(IS)) versus analyte concentration, and good linear correlations were obtained. The characteristic mass was 40 pg Se. Limits of detection were 0.55 and 0.40 mu g L-1 with As and Ge as the internal standard, respectively. Relative standard deviations (RSD) for a sample containing 25 mu g L-1 Se were 1.2% and 1.0% (n = 12) using As and Ge, respectively. The RSD without internal standardization was about 6%. The accuracy of the proposed method was evaluated by an addition-recovery experiment and all recovered values were in the 99-105% range with IS and in the 70-80% range without IS. Using Ge as the internal standard, results of analysis of standard reference materials were in agreement with certified values at a 95% confidence level. The selenium concentration for 10 analyzed milk samples varied from 5.0 to 20 mu g L-1. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A flow-injection (FI) method was developed for the determination of oxalate in urine. It was based on the use of oxalate oxidase (E.C. 1.2.3.4) immobilized on ground seeds of the BR-303 Sorghum vulgare variety. A reactor was filled with this activated material, and the samples (200 μL) containing oxalate were passed through it, carried by a deionized water flow. The carbon dioxide produced by the enzyme reaction permeated through a microporous PTFE membrane, and was received in a water acceptor stream, promoting conductivity changes proportional to the oxalate concentration in the sample. The results obtained showed a useful linear range from 0.05 to 0.50 mmol dm-3. The proposed method, when compared with the Sigma enzymatic procedure, showed good correlation (Y = 0.006(±0.016) + 0.98(±0.019)X; r = 0.9995, Y = conductivity in μS, and X = concentration in mmol dm-3), selectivity, and sensitivity. The new immobilization approach promotes greater stability, allowing oxalate determination for 6 months. About 13 determinations can be performed per hour. The precision of the proposed method is about ± 3.2 % (r.s.d).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Abbott Cell-Dyn 3000 automated hematological analyzer prepares a histogram of platelet volume, which is measured by a technique using electrical impedance, inferring from its platelet count (PLT), mean platelet volume (MPV) and platelet distribution width (PDW). This equipment also calculates the plateletcrit (PCT). These platelet parameters may be important to evaluate platelet function, but they require standardization, because platelets swell when in contact with ethylenediaminetetra-acetic acid salts, hence an increase in blood sample storage time produces artificially increased results. To assess the effect of storage time on MPV, PLT, PDW and PCT, blood samples from 23 sickle cell anemia patients during steady state (Group I) and 50 from healthy controls (Group II) were placed in Vacutainer® tubes with dipotassium ethylenediaminetetra-acetic acid and measured over a period of 1440 minutes (24 h) at the following times: immediately after the venipuncture (time 0), 15, 30, 60, 120, 240, 360, 480 and 1440 minutes. The mean values of MPV and PCT were significantly increased (p<0.00001) along the storage time in both groups. The mean values of PLT and PDW were practically stable (p>0.05) throughout the storage time in both groups.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An analysis of the performances of three important methods for generators and loads loss allocation is presented. The discussed methods are: based on pro-rata technique; based on the incremental technique; and based on matrices of circuit. The algorithms are tested considering different generation conditions, using a known electric power system: IEEE 14 bus. Presented and discussed results verify: the location and the magnitude of generators and loads; the possibility to have agents well or poorly located in each network configuration; the discriminatory behavior considering variations in the power flow in the transmission lines. © 2004 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Low flexibility and reliability in the operation of radial distribution networks make those systems be constructed with extra equipment as sectionalising switches in order to reconfigure the network, so the operation quality of the network can be improved. Thus, sectionalising switches are used for fault isolation and for configuration management (reconfiguration). Moreover, distribution systems are being impacted by the increasing insertion of distributed generators. Hence, distributed generation became one of the relevant parameters in the evaluation of systems reconfiguration. Distributed generation may affect distribution networks operation in various ways, causing noticeable impacts depending on its location. Thus, the loss allocation problem becomes more important considering the possibility of open access to the distribution networks. In this work, a graphic simulator for distribution networks with reconfiguration and loss allocation functions, is presented. Reconfiguration problem is solved through a heuristic methodology, using a robust power flow algorithm based on the current summation backward-forward technique, considering distributed generation. Four different loss allocation methods (Zbus, Direct Loss Coefficient, Substitution and Marginal Loss Coefficient) are implemented and compared. Results for a 32-bus medium voltage distribution network, are presented and discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Open access philosophy applied by regulatory agencies may lead to a scenario where captive consumers will solely face the responsibility on distribution network's losses even with Independent Energy Producers (also known as Distributed Generation) and Independent Energy Consumers connected to the system. This work proposes the utilization of a loss allocation method in distribution systems where open access is allowed, in which cross-subsidies, that appear due to the influence the generators have over the system losses, are minimized. Thus, guaranteeing to some extent the efficiency and transparency of the economic signals of the market. Results obtained through the Zbus loss allocation method adapted for distribution networks are processed in such a way that the corresponding allocation to the generation buses is divided among the consumer buses, while still considering consumers spatial characteristics. © 2007 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and applicable method for non-exhaustive aerobic evaluation in running rats is described. Wistar rats were submitted to running test at different velocities (10, 15, 20, 25 m/min) with 48 h recovery among them. At each velocity, the rats ran two bouts of 5 min with 2 min of rest between bouts. Blood samples were collected at the end of each bout for lactate determination. For each intensity, delta lactate was calculated and using deltas obtained by four tests, an individual linear interpolation was plotted. The y-intercept of linear interpolation was the null delta lactate equivalent to the critical velocity (CV). To verify the lactate stabilization at CV, the animals were submitted to 25 min of continuous exercise (15, 20, 25 m/min), with blood collection every 5 min. The estimated CV was 16.6±0.7 m/min, with significant linear regressions (R=0.90±0.03). The rats presented maximal lactate steady state (MLSS) at 3.9±0.4 mmol/L, at 20 m/min. The CV was less than MLSS but significantly correlated with this parameter (r=0.78). This non-exhaustive test seems to be valid for the aerobic evaluation of sedentary rats and this protocol underestimates the MLSS in 20%. This test seems to be the interesting method for the evaluation of rats submitted to acute exercise or physical training.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work the chaotic behavior of a micro-mechanical resonator with electrostatic forces on both sides is suppressed. The aim is to control the system in an orbit of the analytical solution obtained by the Method of Multiple Scales. Two control strategies are used for controlling the trajectory of the system, namely: State Dependent Riccati Equation (SDRE) Control and Optimal Linear Feedback Control (OLFC). The controls proved effectiveness in controlling the trajectory of the system. Additionally, the robustness of each strategy is tested considering the presence of parametric errors and measurement noise in control. © 2012 American Institute of Physics.