175 resultados para Leg Length
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Aim. Duplex scanning has been used in the evaluation of the aorta and proximal arteries of the lower extremities, but has limitations in evaluating the arteries of the leg. The utilization of ultrasonographic contrast (USC) may be helpful in improving the quality of the image in these arteries. The objective of the present study was to verify whether the USC increases the diagnostic accuracy of patency of the leg arteries and if it diminishes the time needed to perform duplex scanning.Methods. Twenty patients with critical ischemia (20 lower extremities) were examined by standard duplex scanning, duplex scanning with contrast and digital subtraction arteriography (DSA). The 3 arteries of the leg were divided into 3 segments, for a total of 9 segments per limb. Each segment was evaluated for patency in order to compare the 3 diagnostic methods. Comparison was made between standard duplex scanning and duplex scanning with contrast in terms of quality of the color-coded Doppler signal and of the spectral curve, and also of the time to perform the exams.Results. Duplex scanning with contrast was similar to arteriography in relation to patency diagnosis (p>0.3) and even superior in some of the segments. Standard duplex scanning was inferior to arteriography and to duplex scanning with contrast (p<0.001). There were improvements of 70% in intensity of the color-coded Doppler signal and 76% in the spectral curve after the utilization of contrast. The time necessary to perform the examinations was 23.7 minutes for standard duplex scanning and 16.9 minutes for duplex scanning with contrast (p<0.001).Conclusion. The use of ultrasonographic contrast increased the accuracy of the diagnosis of patency of leg arteries and diminished the time necessary for the execution of duplex scanning.
Resumo:
OBJETIVO: Avaliar o desempenho da análise de imagem digital na estimativa da área acometida pelas úlceras crônicas dos membros inferiores. MÉTODOS: Estudo prospectivo em que foram mensuradas úlceras empregando o método planimétrico clássico, utilizando desenho dos seus contornos em filme plástico transparente, medida sua área posteriormente por folha milimetrada. Esses valores foram utilizados como padrão para a comparação com a estimativa de área pelas fotografias digitais padronizadas das úlceras e dos desenhos das mesmas em filme plástico. Para criar um referencial de conversão dos pixels em milímetros, foi empregado um adesivo com tamanho conhecido, adjacente à úlcera. RESULTADOS: foram avaliadas 42 lesões em 20 pacientes portadores de úlceras crônicas de membros inferiores. As áreas das úlceras variaram de 0,24 a 101,65cm². Observou-se forte correlação entre as medidas planimétricas e as fotos das úlceras (R²=0,86 p<0,01), porém a correlação das medidas planimétricas com as fotos digitais dos desenhos das úlceras foi ainda maior (R²=0,99 p<0,01). CONCLUSÃO: A fotografia digital padronizada revelou-se método rápido, preciso e não-invasivo capaz de estimar a área afetada por úlceras. A avaliação das medidas fotográficas dos contornos das úlceras deve ser preferida em relação à análise de sua fotografia direta.
Resumo:
Objective: Alterations in the size of the [CAG](n) repeats of the AR gene have been described in several types tumors. The purpose of this study was to evaluate if there is an association between the AR [CAG](n) repeat alleles and the relative risk for head and neck cancer and to analyse microsatellite instability (MSI) and loss of heterozygosity (LOH) in these tumors.Design: Matched samples of blood and head and neck tumors were evaluated using two methodologies, silver-stained gels to perform the analyses of MSI and LOH, and automated analysis to confirm these results and for genotyping of the AR [CAG](n), repeat length. Sixty-nine individuals without cancer were used as a control group for both procedures. The Log-rank test was used to compare overall survival and disease-free survival curves. The Cox proportional hazards regression models were performed to determine the [CAG], repeats as an independent prognostic factor.Results: Patients with alleles <= 20 in the male group showed a correlation with lower disease-free survival (P = 0.0325) and with recurrence or metastasis (RR 2.52, CI 95%). in the female group, the allele 2 (longer allele) showed a significant lower mean of [CAG](n), repeat when compared to the control group. Microsatellite instability was detected in nine cases in both procedures. In six out of these nine cases, we observed a reduction of the AR [CAG](n) repeat length. LOH was detected in one out of 17 women informative for oral cancer in both procedures.Conclusion: These results suggest that short [CAG](n) repeat length (: 20) polymorphism is associated with poor prognosis in a subset of male patients with head and neck cancer and that AR gene microsatellite instability is uncommon in these tumors. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Avaliaram-se o desempenho e a qualidade da carne de frangos de corte alimentados com diferentes níveis de sorgo, do cultivar SAARA, com 0,49g/kg de tanino, em substituição ao milho. Os 2600 pintos sexados de um dia de idade, da linhagem Ross 308, foram distribuídos em delineamento inteiramente ao acaso, com esquema fatorial 5×2 (cinco níveis de sorgo - 0, 25, 50, 75 e 100% e dois sexos), e quatro repetições de 65 aves por unidade experimental. Não houve efeito (P>0,05) da substituição do milho pelo sorgo sobre as características de desempenho, de rendimentos de carcaça, carne de peito e pernas, de composição química e sensoriais. O pH observado nas carnes de peito e pernas foi maior para os machos (P<0,05), e houve diminuição do pH à medida que se aumentaram os níveis de substituição. Os machos apresentaram os maiores valores nas medidas de comprimento, largura e espessura do filé. Na carne do peito dos machos, ocorreu maior perda de peso por cozimento e força de cisalhamento (P<0,05). Observou-se diminuição (P<0,05) dos valores de a (vermelho) e b (amarelo) e aumento de L (luminosidade) à medida que aumentaram os níveis de substituição.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
O trabalho foi conduzido com o objetivo de avaliar o efeito de diferentes linhagens (conformação versus convencionais) sobre o desempenho, rendimento de carcaça e partes, medidas físicas (espessura, largura e comprimento do filé do peito) e qualidade da carne do peito (perda de peso por cozimento, maciez e pH) em frangos de corte com 35, 42 e 49 dias. Foram utilizados 2400 pintos de um dia, distribuídos em um delineamento inteiramente casualizado em fatorial 5x2, com cinco linhagens (conformação A, B e C ; e convencionais D e E) e dois sexos, com quatro repetições de 60 aves cada. O crescimento das aves foi diferente, havendo linhagens com maior crescimento tanto entre as de conformação quanto entre as convencionais. As linhagens apresentaram desempenho diferenciado para ganho de peso, consumo de ração e conversão alimentar. Os animais de algumas linhagens de conformação apresentaram desempenho superior às convencionais, mas o oposto também foi verificado. O rendimento de carcaça diferiu aos 35 dias, com as linhagens de conformação apresentando os maiores rendimentos. O rendimento de pernas e carne de pernas foi semelhante ou melhor nas linhagens convencionais e os maiores rendimentos de peito e carne de peito ocorreram nas linhagens de conformação. A gordura abdominal diferiu aos 42 dias somente entre as linhagens de conformação. A espessura, largura e comprimento dos filés do peito também foram diferentes, com as linhagens de conformação apresentando valores semelhantes entre si e superiores aos das linhagens convencionais. Não houve diferenças nos parâmetros de qualidade da carne. O sexo das aves teve influência tanto no desempenho quanto no rendimento de carcaça e partes, porém não afetou a qualidade da carne do peito.
Resumo:
This study aimed to evaluate the effects of probiotics and prebiotics of bacterial and yeast origin on the performance, development of the digestive system, carcass yield and meat quality of free-range broiler chickens. Five hundred and sixty male chicks of the strain ISA S757-N were reared from one to 84 days old. The birds were distributed in four treatments according to a completely randomized block design: T1 = Control, T2 = Probiotics and Prebiotics of bacterial origin, T3 = Probiotics and prebiotics of yeast origin, T4 = Probiotics and prebiotics of bacterial origin + probiotics and prebiotics of yeast origin. There were four repetitions with 35 birds per repetition, and the birds had access to a pasture area after 35 days of age. Characteristics evaluated were performance, development of the digestive system, carcass and parts yield, abdominal fat, breast meat physical measurements (length, width and height) and meat quality parameters (pH from breast and leg meat, cooking loss and shearing force from breast meat). Lower mortality (p<0.05) and higher weight gain from 64 to 77 and 64 to 84 days of age were seen in birds supplemented with probiotics and prebiotics of bacterial origin compared to the non-supplemented birds (control). There were significant differences (p<0.05) among treatments for carcass yield. Birds supplemented with both probiotics and prebiotics of microbial and yeast origin (T4) showed higher carcass yield than control birds. Supplementation with probiotics and prebiotics of bacterial origin (T2) or the supplementation of these together with those of yeast origin (T4) reduced mortality and increased the carcass yield in free-range broiler chickens.
Resumo:
Speciation of Taenia in human stool is important because of their different clinical and epidemiological features. DNA analysis has recently become possible which overcomes the problems of differentiating human taeniid cestodes morphologically. In the present study, we evaluated PCR coupled to restriction fragment length polymorphism to differentiate Taenia solium from Taenia saginata eggs present in fecal samples from naturally infected patients. A different Dral-RFLP pattern: a two-band pattern (421 and 100 bp) for T saginata and a three-band pattern (234, 188, and 99 bp) for T solium was observed allowing the two species to be separated.. The lower detection limit of the PCR-RFLP using a non-infected fecal sample prepared with a given number of T saginata eggs was 34 eggs in 2 g stool sediment. The 521 bp mtDNA fragment was detected in 8 out of 12 Taenia sp. carriers (66.6%). of these, three showed a T solium pattern and five a T saginata pattern. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Objectives: the purpose of this study is to employ optical microscopy to measure the thickness of the hybrid layer and the penetration (tags) of an aggressive self-etching adhesive system into sound dentin.Methods: occtusat cavities were prepared in 40 extracted human posterior teeth. The prepared teeth were randomly assigned to four experimental groups with 10 specimens each. The self-etching adhesive system Adper Prompt L-Pop was applied to the dentin surface as follows: Group 1: cavosurface enamel was etched for 60 s and dentin for 20 s with 35% phosphoric acid get, immediately followed by application of the self -etching adhesive with a brush to the entire cavity for 15 s; Groups 2, 3, and 4: no pre-etching was performed, and the self -etching adhesive was applied to both enamel and dentin for 15, 30 and 45 s, respectively. After curing, the cavities were fitted with composite resin Fittek Z250. Afterwards, the teeth were decalcified and the restorations were carefully removed for later embedding in paraffin. The specimens were serially sectioned at 6 mu m of thickness and sequentially mounted in glass slides. These sections were stained with Brown and Brenn staining for posterior analysis and measurement of the hybrid layer and resin tags on a tight microscope with a micrometric ocular 40/075. The results were submitted to analysis of variance at the 5% level.Results: whenever there was significance, the Tukey test was applied at the 5% level. The specimens receiving application of acid etching before the selfetching. adhesive displayed a larger thickness of the hybrid layer; on the other hand, specimens receiving only application of the self -etching adhesive on dentin for 15, 30 and 45 s exhibited similar thickness of the hybrid layer. As regards the resin tags, no statistically significant differences could be found between the study groups.Conclusions: it could be concluded that the increase in the time of application of the self-etching adhesive Adper Prompt L-Pop did not significantly influence the formation and thickness of hybrid layer, as well as its penetration into the sound dentin surface. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Purpose: the purpose of this in vivo study was to compare the accuracy of primary incisor length determined by direct digital radiography (straight-line measurement and grid superimposition) and measurement of the actual tooth length. Methods. Twenty-two primary maxillary incisors that required extractions were selected from 3- to 5-year-old children. The teeth were radiographed with an intraoral sensor using the long cone technique and a sensor holder (30-cm focus-to-sensor distance). The exposure time was 03 seconds. Tooth length was estimated by using straight-line and grid measurements provided by the distance measurement feature of the Computed Dental Radiography digital dental imaging system. The actual tooth length was obtained by measuring the extracted tooth with G digital caliper. Data were analyzed statistically by Pearson's correlation coefficient and a paired t test. Results: There were statistically significant differences (P=.007) between the 2 measurement techniques and between the actual tooth lengths and grid measurements. There was no statistically significant difference (P=38) between straight-line measurements and actual tooth lengths, showing that the straight-line measurements were more accurate. Underestimation of the actual tooth length, however, occurred in 45% of the straight-line measurements and in 73% of the grid measurements. Conclusion: It is possible to determine primary tooth length in digital radiographs using onscreen measurements with 0 reasonable degree of accuracy.
Resumo:
P>AimTo compare the efficacy of different digital radiographic imaging systems for determining the length of endodontic files.MethodologyK-type endodontic files were introduced into the canals of 40 extracted human permanent single-rooted teeth and fixed in place at random lengths. The teeth were radiographed using Digora Optime (R), CygnusRay MPS (R) and CDR Wireless (R) digital imaging systems. Six observers measured every file length in all the images and repeated this procedure in 50% of the image samples, and assigned a score to the level of difficulty found. Analysis of variance for differences between digital systems and Tukey's test were performed. The level of intraobserver agreement was measured by intraclass correlation. The assigned scores were evaluated by Kruskal-Wallis and Dunn's tests.ResultsThe CDR Wireless values did not differ significantly from the actual lengths and the CygnusRay MPS values. The Digora Optime system was significantly different from the others and overestimated the values (P < 0.05). The Digora Optime was significantly easier to use for taking measurements and the CygnusRay MPS the most difficult (P < 0.05). All digital radiographic imaging systems showed excellent agreement with the Intraclass Correlation Coefficient > 0.95.ConclusionsThe three digital radiographic imaging systems were precise. The CDR Wireless system was significantly more accurate in determining endodontic file lengths, and similarly to Digora Optime, was considered the least difficult to use when assessing endodontic file lengths.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJETIVO: Verificar a influência de dois diferentes intervalos de recuperação (IR) entre as séries no exercício leg-press sobre o número e sustentabilidade das repetições e no volume total, em idosas não treinadas. MÉTODOS: Onze idosas (66,5 ± 5,0 anos; 59,2 ± 9,1kg; 146,4 ± 34,9cm) foram submetidas a duas sessões experimentais de exercícios com pesos com intensidade de 15 repetições máximas. Cada sessão experimental foi composta por três séries realizadas até a fadiga muscular utilizando IR de um (IR-1) ou três minutos (IR-3). As sessões experimentais foram separadas por, no mínimo, 48 horas. Todas as participantes realizaram ambos os protocolos e um delineamento cross-over balanceado foi utilizado para determinar a ordem das sessões experimentais. RESULTADOS: Para ambos os IR entre as séries, reduções significativas (P < 0,05) no número e na sustentabilidade das repetições foram observadas da primeira para a segunda e terceira séries e da segunda para a terceira séries. Diferenças significativas (P < 0,05) entre os IR foram observadas nas duas séries finais. O volume total da sessão realizada com IR-3 foi estatisticamente superior (20,4%; P < 0,05) quando comparada a sessão IR-1. CONCLUSÃO: O número e a sustentabilidade das repetições e o volume total de treino de idosas não treinadas são influenciados pelo IR empregado entre as séries. Maiores IR devem ser utilizados quando a finalidade for otimizar o volume de treino por meio da sustentabilidade das repetições. Em contrapartida, menores IR devem ser utilizados quando a meta for obter maiores níveis de fadiga muscular.