94 resultados para Isometric Axial Rotation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Soil and subsoil aluminium toxicity has been one of the main limiting factors for soybean and wheat yields in tropical soils. Usually liming is the most effective way to deal with soil acidity and Al toxicity, but in no-till systems the soil is not disturbed making it impossible to incorporate lime in the arable layer, and lime has been usually applied on the soil surface. In this paper soybean and wheat responses to lime applied on the soil surface and/or incorporated in the soil arable layer were evaluated during the transition from conventional tillage to a no-till system. The experiment was conducted for 3 years in Parana, Brazil, using a wheat-soybean rotation. Lime rates ranging from 0.0 to 9.0 t ha(-1) were incorporated down to 20 cm and 4.5 t ha(-1) were spread or not on the soil surface. Soil samples were taken down to 60 cm, 39 months after the first lime application. Soil chemical characteristics were affected by lime application down to 60 cm deep in the profile. Soybean responded to lime irrespective of application method, but the highest accumulated yield was obtained when lime was incorporated into the arable layer. For wheat, the more sensitive the cultivar, the greater was the response to lime. During the introduction of a no-till system, lime must be incorporated into the arable layer when the wheat cultivar is Al-sensitive. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of this study were to evaluate, through panoramic radiographs, the mesiodistal axial inclinations of the maxillary anterior teeth at the beginning and end of nonextraction orthodontic treatment, and to compare the results with the mesiodistal axial inclinations of a control sample with normal (acceptable) occlusions. Methods: the experimental sample consisted of 40 white patients (20 male, 20 female; mean age, 14 years) with Class I maloccusions who were treated orthodontically with a standard edgewise (not preadjusted) technique without extractions. The mean treatment period was 1.6 years. The control sample comprised 42 white subjects (14 male, 28 female; age range, 12-17 years) with untreated normal (acceptable) occlusions. Panoramic radiographs were taken of the patients at the beginning (T1) and end (T2) of treatment. The mean values of the mesiodistal axial inclination at T1 were compared with the mean values at T2, and both were compared with the mesiodistal axial inclinations of the control sample. Results- the mesiodistal axial inclinations of the maxillary anterior teeth of the experimental group at T1 were different from those of the control group for 50% of the evaluated teeth. In contrast, the inclinations at T2 were consistent with the normal anatomical configuration of the controls. Conclusions: the panoramic radiograph is an effective tool for evaluating the mesiodistal axial inclinations of maxillary anterior teeth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show that all Green's functions of the Schwinger and axial models can be obtained one from the other. In particular, we show that the two models have the same chiral anomaly. Finally it is demonstrated that the Schwinger model can keep gauge invariance for an arbitrary mass, dispensing with an additional gauge group integration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The feasibility of Portland cement analysis by introduction of slurries in an inductively coupled plasma optical emission spectrometer (ICP-OES) with axial viewing has been evaluated. After a fast manual grinding of the cement samples, owing to the pulverized state of this material, 0.1% m/v slurries were prepared in 1% v/v HCl. The calibration was performed adopting two strategies: one based on slurries prepared from different masses (50, 75, 100 and 125 mg) of a Portland cement standard reference material (NIST SRM 1881), and the other one based on aqueous reference solutions. A complete analysis of cement for major (Al, Ca, Fe, Mg and Si), minor and trace elements (Mn, P, S, Sr and Ti) was accomplished. Both strategies led to accurate results for commercial Portland cement samples, except for Si and Ti. for which the calibration with aqueous reference solutions resulted in low values. Applying a paired t-test it was shown that most results were in agreement at a 95% confidence level with a conventional fusion decomposition procedure. The ICP-OES with axial viewing and end-on gas configuration for removal of the recombination plasma zone was effective for cement slurry analysis without any undesirable particle deposition in the pre-optics interface and without severe spectral interferences. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a comparative analysis about the behaviour of pile caps supported by 3 piles subjected to axial loading. Piles with 20 cm and 30 cm diameters were analysed. The main reinforcement was maintained in all the specimens, however, the arrangement of the secondary reinforcement varied. The main reinforcement consisted of steel bars connecting the piles. The secondary reinforcement was made up of: (a) bars going through the piles and through the projection of the column, (b) bars forming a network, and (c) vertical and horizontal stirrups. The main objective was the observation of the pile cap behaviour regarding the cracks and the modes of rupture. The real scale specimens were subjected to experimental tests until failure by rupture. Instruments were placed with the aim to obtain the displacement of the bases, the strains in the main and secondary reinforcement bars, in the compression struts, in the lower and upper nodal zones and in the sides of the caps. None of the caps reached failure by rupture with a load less than 1.12 times the theoretical load. The specimens ruptured due to the cracking of the compression strut and/or the yielding of the reinforcement bars in one direction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider an extension of the axial model where local gauge symmetries are taken into account. The result is a mixing of the axial and Schwinger models. The anomaly of the axial current is calculated by means of the Fujikawa path integral technique and the model is also solved. Besides the well-known features of the particular models (axial and Schwinger) an effective interaction of scalar and gauge fields via a topological current is obtained. This term is responsible for the appearance of massive poles in the propagators that are different from those of both models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magneto-optical rotation was measured at room temperature for glasses containing Bi2O3-CdO-GeO2 (BCG), and Bi2O3-PbO-GeO2-B2O3 (BPGP). A pulsed magnetic field between 50 and 80 KG was used to measure Faraday rotation at 632.8 nm as a function of the concentration of Bi and Cd for BCG and Bi and Pb for BPGB. Verdet constant as high as 0.162 min G-1 cm-1 at 632.8 nm for the BPGB sample with the highest concentrations of Bi and Cd was found. Verdet constant increases linearly with the heavy-metal concentration for the BPGB whereas it reaches some saturation for the BCG system. Measurements of the magneto-optical rotation at other wavelengths in the visible and the refractive index at 632.8 nm are also reported. © 1998 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we consider the two-point Green's functions in (1 + 1)-dimensional quantum electrodynamics and show that the correct implementation of analytic regularization gives a gauge invariant result for the vacuum polarization amplitude and the correct coefficient for the axial anomaly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to analyze the electromyographic (EMG) signal behavior of rectus femoris (RF), vastus medialis (VM), vastus lateralis (VL) and biceps femoris (caput longum) (BFCL) from nine women during fatiguing dynamic and isometric knee extensions tests and to determine their EMGFT (Electromyographic Fatigue Threshold). Surface electrodes, biological signal acquisition module, analogical-digital converter board and specific software were used. The RMS (Root Mean Square) values obtained from concentric phase (80 to 30 degrees) of the dynamic knee extension andfrom isometric contraction were correlated with time on each load by linear regression analysis. The respective slopes were correlated with the correspondent load to determine the EMGFT. Force (Kgf) and median frequency - MF (Hz) obtained during MIVC (Maximal Isometric Voluntary Contraction) performed before and after the fatiguing tests were calculated in Matlab environment. The results demonstrated that the endurance time decreases with higher loads the EMG amplitude increase with time and was greater at higher loads, between muscles in dynamic exercise the RF and VL showed higher slopes, and in isometric exercise the VL showed the same behavior The EMGFT values were similar in both exercises; the force values predominantly decreased after fatiguing tests; however the MF only decreased after some loads. The protocols proposed allowed standardizing protocols at least to induce the fatigue process and to determine the EMGFT as an endurance indicative, which may be used to evaluate the effectiveness of rehabilitative or training interventions indicated to reduce muscle weakness and fatigue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to investigate if chronic eccentric strength training (ST) affects heart rate (HR) and heart rate variability (HRV) during sub-maximal isometric voluntary contractions (SIVC). The training group (TG) (9 men, 62 ± 2) was submitted to ST (12 weeks, 2 days/week, 2 - 4 sets of 8-12 repetitions at 75-80% peak torque (PT). The control group (CG) (8 men, 64 ± 4) did not perform ST. The HR and the HRV (RMSSD index) were evaluated during SIVC of the knee extension (15, 30 and 40% of PT). ST increased the eccentric torque only in TG, but did not change the isometric PT and the duration of SIVC. During SIVC, the HR response pattern and the RMSSD index were similar for both groups in pre- and post-training evaluations. Although ST increased the eccentric torque in the TG, it did not generate changes in HR or HRV. © Springer-Verlag 2008.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to compare the torque, torque ratio (Hamstrings:Quadriceps - H:Q), electromyographic (EMG) activity and EMG ratio (knee flexors:knee extensors EMG) in soccer players (SG, N=10) and active subjects (AG, N=10). Subjects performed three maximal voluntary isometric knee extensions and flexions at 45° and 90° to determine the peak torque and EMG activity. Torque and EMG activity of the knee flexor (biceps femoris [BF] and semitendinosus [ST]) were divided by the torque and EMG activity of the knee extensor (vastuls lateralis [VL] and rectus femoris [RF]) to calculate torque ratios (H:Q) and EMG ratios (BF:VL, BF:RF, ST:VL, ST:RF). The flexion torque was significantly higher for SG (p<0.05) in 45° and 90°. EMG activity for SG was significantly higher in agonist contractions for VL, RF and ST, and significantly lower in antagonist contractions for RF and ST when compared to AG Torque and EMG ratios were similar between groups and there were good correlations between torque ratio and BF:VL ratio (r=0.71, p=0.02) and BF:RF ratio (r=0.81, p=0.004) at 45. The EMG results could overestimate the joint balance calculated using torque ratios. Differences in recruitment pattern between soccer players and non-athletes can be related to the training routines and the EMG ratios presents applicable in trained populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The correct radiographic identification of ossification of the pterygospinous and pterygoalar ligaments plays an important role in surgical procedures for the treatment of trigeminal neuralgia. Most of these procedures are performed through the foramen ovale, a site where these ligaments can be found to be partially or completely ossified. We studied the radiographic features of these ossified ligaments and their location in relation to the foramen ovale by the Hirtz axial technique. For this purpose, 93 dry skulls from the Discipline of Anatomy, São José dos Campos Dental School, UNESP, which presented partial or complete ossification of these ligaments, were radiographed. The pterygospinous ligament was detected on 27.97% of radiographs and was partially ossified in 19.36% of cases and completely ossified in 8.61%. The pterygoalar ligament was present in 62.35% of radiographs, being partially ossified in 49.44% and completely ossified in 12.91%. The pterygospinous ligaments was found to be partially and completely ossified on the same radiograph in 3.23% of cases, whereas the pterygoalar ligament appeared partially and completely ossified on the same radiograph in 6.45%. Furthermore, the pterygospinous ligament was thinner than the pterygoalar ligament and located more medially in relation to the foramen ovale. The pterygoalar ligament formed a large bone bar lateral to the foramen ovale, often obliterating the lumen of the latter. The Hirtz axial technique is an excellent tool for the observation of complete or partial ossification of the pterygospinous and pterygoalar ligaments in surgical procedures for the treatment of trigeminal neuralgia performed through the foramen ovale.