116 resultados para Instrumentation (Physics)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To evaluate the healing of experimentally induced chronic periapical lesions in dogs at 30, 75, and 120 days after root canal instrumentation with rotary NiTi files or manual K-files, with or without a calcium hydroxide/1% chlorhexidine paste intracanal dressing.Study design. The second, third, and fourth mandibular premolars and the second and third maxillary premolars of 5 dogs (12 to 18 months of age, weighing 8 to 15 kg) were selected for treatment (a total of 82 root canals). After pulp removal, the root canals were left exposed to the oral cavity for 7 days to allow microbial contamination, after which the root canals were sealed with ZOE cement until periapical lesions were confirmed with radiography. Group I and II teeth were instrumented with manual K-files using the crown-down technique. In group III and IV teeth, NiTi rotary files were used. The apical delta was perforated by using #20 to #30 K-files at the length of the tooth, thus creating a standardized apical opening. The apical stop was enlarged to size 70, with 2.5% sodium hypochlorite irrigation at each file change. Teeth in groups II and IV were dressed with calcium hydroxide (Ca(OH)(2))/1% chlorhexidine (CHX) paste for 15 days before root filling. Group I and III teeth did not receive an intracanal dressing. The access openings of the teeth were permanently restored with silver amalgam condensed on a glass ionomer cement base. Pairs of standardized periapical radiographs were taken at the beginning of the treatment (0 days) and at 30, 75, and 120 days after filling.Results. There was no significant difference in the rate of radiographic healing of the periapical lesions between manual and rotary instrumentation. Radiographs taken at 120 days showed that the treatment with Ca(OH)(2)/1% CHX paste resulted in a significant reduction in mean size of the periapical lesions in comparison to single-session treatment. These findings were also true for histologic observations.Conclusion. The findings support the hypothesis that, regardless of the instrumentation technique (manual or rotary), the use of an intracanal dressing is important in the endodontic treatment of dog's teeth with experimentally induced chronic periapical lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper explains the conceptual design of instrumentation that measures electric quantities defined in the Std. 1459-2000. It is shown how the instantaneous-space-phasor approach, based on alpha, beta, 0 components, can be used to monitor electric energy flow, evaluate the utilization of transmission line, and quantify the level of harmonic pollution injected by nonlinear loads.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The DO experiment at Fermilab's Tevatron will record several petabytes of data over the next five years in pursuing the goals of understanding nature and searching for the origin of mass. Computing resources required to analyze these data far exceed capabilities of any one institution. Moreover, the widely scattered geographical distribution of DO collaborators poses further serious difficulties for optimal use of human and computing resources. These difficulties will exacerbate in future high energy physics experiments, like the LHC. The computing grid has long been recognized as a solution to these problems. This technology is being made a more immediate reality to end users in DO by developing a grid in the DO Southern Analysis Region (DOSAR), DOSAR-Grid, using a available resources within it and a home-grown local task manager, McFarm. We will present the architecture in which the DOSAR-Grid is implemented, the use of technology and the functionality of the grid, and the experience from operating the grid in simulation, reprocessing and data analyses for a currently running HEP experiment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The SLD Barrel Cherenkov Ring Imaging Detector was fully operational in the 1992 physics data run. The electron drift velocity and magnetic field deflection of electron trajectories have been measured. Cherenkov rings have been observed from both the liquid and gas radiators. The number and the resolution of the angle of Cherenkov photons have been measured to be approximately equal to design specifications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: the purpose of this study was to evaluate the effect of erbium:yttrium-aluminum-garnet laser instrumentation of root surfaces on the morphology of fibroblasts from continuous lineage. Method and materials: Dentinal slices with 4 mm(2) of surface area were obtained from teeth extracted for severe periodontal involvement. Specimens were assigned to one of three treatment groups: group 1, application of the laser with an energy level of 250 mJ at 103 pulses per second; group 2, application of the laser with an energy level of 80 mJ at 166 pulses per second; and group 3, similar to group 2, but with concomitant water irrigation of the device. The specimens were incubated in multiwell plates containing cell culture media. After 24 hours, the specimens were submitted to routine preparation for scanning electron microscopy. Three independent and blind examiners used photomicrographs to evaluate the morphology of the fibroblasts: 0 = without cells; 1 = flat cells; 2 = round cells; and 3 = combination of round and flat cells. Results: Statistical analysis indicated that there were significant differences among treatment groups and that group 3 was significantly different from groups 1 and 2. Conclusion: There was no difference between groups 1 and 2 in the morphology of fibroblasts. Laser instrumentation with concomitant irrigation impaired the adhesion of fibroblasts to dentinal surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We explore the potential of the Next Linear Collider, operating in the e γ mode, to disentangle new physics scenarios in single W production. We study the effects related to the exchange of composite fermions in the reaction e γ→Wνe, and compare them with those arising from trilinear gauge boson anomalous couplings. We stress the role played by the initial state polarization to increase the reach of this machine and to discriminate the possible origin of the new phenomena.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We obtain constraints on possible anomalous interactions of the top quark with the electroweak vector bosons arising from the precision measurements at the Z pole. In the framework of SU(2)L ⊕ U(1)Y chiral Lagrangians, we examine all effective CP-conserving operators of dimension five which induce fermionic currents involving the top quark. We constrain the magnitudes of these anomalous interactions by evaluating their one-loop contributions to the Z pole physics. Our analysis shows that the operators that contribute to the LEP observables get bounds close to the theoretical expectation for their anomalous couplings. We also show that those which break the SU(2)C custodial symmetry are more strongly bounded. © 1997 Elsevier Science B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work deals with the design of the Institute of Physics of the University of São Paulo (IFUSP) main racetrack microtron accelerator end magnets. This is the last stage of acceleration, comprised of an accelerating section (1.04 m) and two end magnets (0.1585 T), in which a 5.10 MeV beam, produced by a racetrack microtron booster has its energy raised up to 31.15 MeV after 28 accelerations. POISSON code was used to give the final configuration that includes auxiliary pole pieces (clamps) and auxiliary homogenizing gaps. The clamps create a reverse fringe field region and avoid the vertical defocusing and the horizontal displacement of the beam produced by extended fringe fields; PTRACE code was used to perform the trajectory calculations in the fringe field region. The auxiliary homogenizing gaps improve the field uniformity as they create a magnetic shower that provides uniformity of ±0.3%, before the introduction of the correcting coils that will be attached to the pole faces. This method of correction, used in the IFUSP racetrack microtron booster magnets, enabled uniformity of ±0.001% in an average field of 0.1 T and will also be employed for these end magnets. © 1999 The American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a model of fermion masses based on a minimal, non-Abelian discrete symmetry that reproduces the Yukawa matrices usually associated with U(2) theories of flavor. Mass and mixing angle relations that follow from the simple form of the quark and charged lepton Yukawa textures are therefore common to both theories. We show that the differing representation structure of our horizontal symmetry allows for new solutions to the solar and atmospheric neutrino problems that do not involve modification of the original charged fermion Yukawa textures, or the introduction of sterile neutrinos. (C) 2000 Elsevier Science B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The purpose of this study was to evaluate the effect of erbium:yttrium-aluminum-garnet laser instrumentation of root surfaces on the morphology of fibroblasts from continuous lineage. Method and materials: Dentinal slices with 4 mm2 of surface area were obtained from teeth extracted for severe periodontal involvement. Specimens were assigned to one of three treatment groups: group 1, application of the laser with an energy level of 250 mJ at 103 pulses per second; group 2, application of the laser with an energy level of 80 mJ at 166 pulses per second; and group 3, similar to group 2, but with concomitant water irrigation of the device. The specimens were incubated in multiwell plates containing cell culture media. After 24 hours, the specimens were submitted to routine preparation for scanning electron microscopy. Three independent and blind examiners used photomicrographs to evaluate the morphology of the fibroblasts: 0 = without cells; 1 = flat cells; 2 = round cells; and 3 = combination of round and flat cells. Results: Statistical analysis indicated that there were significant differences among treatment groups and that group 3 was significantly different from groups 1 and 2. Conclusion: There was no difference between groups 1 and 2 in the morphology of fibroblasts. Laser instrumentation with concomitant irrigation impaired the adhesion of fibroblasts to dentinal surfaces.