124 resultados para Industrial water supply


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this study was to evaluate the urinary fluoride excretion of 2- to 7-year-old children exposed to different water fluoride concentrations in the city of Catolé do Rocha, PB, Brazil. Forty-two children were allocated to 3 groups according to the concentration of fluoride in the water: G1 (n=10; 0.5-1.0 ppm F), G2 (n=17; 1.1-1.5 ppm F) and G3 (n= 15; >1.51 ppm F). The study was carried out in two 1-week phases with 1-month interval between the moments of data collection: in the first phase, the children used a fluoride toothpaste (FT) (1,510 ppm F) for 1 week, whereas in the second phase a non-fluoride toothpaste (NFT) was used. The urine was collected in a 24-h period in each week-phase according to Marthaler's protocol. The urinary fluoride excretion data expressed as mean (SD) in ì g/24 h were: G1-FT= 452.9 (290.2); G1-NFT= 435.1 (187.0); G2-FT= 451.4 (224.0); G2-NFT= 430.3 (352.5); G3-FT=592.3 (390.5); and G3-NFT=623.6 (408.7). There was no statistically significant difference between the water fluoride groups, and regardless of the week phase (ANOVA, p>0.05). The use of fluoride toothpaste (1,510 ppmF) did not promote an increase in urinary fluoride excretion. There was a trend, though not significant, as to the increase of urine fluoride concentration in relation to fluoride concentrations in the water. The excretion values suggest that some children are under risk to develop dental fluorosis and information about the appropriate use of fluoride is necessary in this area.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This work introduces an innovative urinal for public convenience, that promotes at the same time water reuse and personal higiene, in a safe and economical way . Furthermore it demonstrates the latest technology and its technical and economical viabillity of utilization in new and already existing buildings facilities. This new model of personal higiene equipment offers as main benefits the improved economy with subsequent decrease in drinkable water consumption, sanitary safety, low cost and easy installation due to its simplicity and to the fact that it can be installed in already existing facilities. The proposal is constituted by a higienic, ecological and smart system for flushing of public urinals. It is a conjugated system of lavatory and urinal that reuses hands higienization water from the lavatory for flushing purpose. The proposed urinal can be operated manually or automatically by means of a presential sensor. The system promotes drinkable water economy by a rational utilization by avoiding the use of waste water from hand washing in place of clean water for flushing. The proposed equipment increases the economy of clean water in a simple and economical way and it can be installed in any type of public lavatory facilitie such as schools, public buildings, hospitals, commercial buildings, bus terminals, airports, stadiums, parking buildings and shopping centers. Additional benefits of the proposed system is the suggestion of hands washing before and after the use of the urinal without contamination risks from focet handling.and render more attractive the installation for a rational use of clean water in commercial and industrial buildings. Pay-back has shown to be very attractive for a number of internal return rates and also very attractive from the point of view of environmental protection.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The microbiological quality of bottled mineral water of various domestic brands sold in Brazil was investigated, with particular focus on the heterotrophic plate count (HPC). Neither total coliforms nor Escherichia coli were found in any 1.5 L bottle samples. Total coliforms were found in 2.9% of the small bottles, while in 20 L bottles the presence of total coliforms and E. coli was demonstrated in 15.5 and 2.4% of samples, respectively. Pseudomonas aeruginosa was detected in 4.3, 4.5 and 9.5% of small, 1.5 and 20 L bottles, respectively. In 36.4% of the samples of 1.5 L bottles, the HPC was above 500 cfu/mL. This percentage of samples with an HPC above 500 cfu/mL increased to 52.0 and 61.9% in small and 20 L bottles, respectively. Higher contamination by total coliforms, E. coli, P. aeruginosa and HPCs occurred in 20 L bottles. In conclusion, several samples in this study were outside the international quality standard for mineral water and the large number of samples with high HPCs shows that more work must be done on the use of HPC in mineral water and the damaging effects that these microorganisms may cause to humans. The bottled mineral water was confirmed as a particularly important public health problem, due to the poor microbiological quality of the products that are marketed. © IWA Publishing 2012.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The municipality of Petrolina, located in the semi-arid region of Brazil, is highlighted as an important agricultural growing region, however the irrigated areas have cleared natural vegetation inducing a loss of biodiversity. To analyze the contrast between these two ecosystems the large scale values of biomass production (BIO), evapotranspiration (ET) and water productivity (WP) were quantified. Monteithś equation was applied for estimating the absorbed photosynthetically active radiation (APAR), while the new SAFER (Simple Algorithm For Evapotranspiration Retrieving) algorithm was used to retrieve ET. The water productivity (WP) was analysed by the ratio of BIO by ET at monthly time scale with four bands of MODIS satellite images together with agrometeorological data for the year of 2011. The period with the highest water productivity values were from March to April in the rainy period for both irrigated and not irrigated conditions. However the largest ET rates were in November for irrigated crops and April for natural vegetation. More uniformity of the vegetation and water variables occurs in natural vegetation, evidenced by the lower values of standard deviation when comparing to irrigated crops, due to the different crop stages, cultural and irrigation managements. The models applied with MODIS satellite images on a large scale are considered to be suitable for water productivity assessments and for quantifying the effects of increasing irrigated areas over natural vegetation on regional water consumption in situations of quick changing land use pattern. © 2012 SPIE.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Common Bean (Phaseolus vulgaris L.) is widespread in the social and economic scene in Brazil, as well it is Brazilian population main dish, and it also helps small and medium farmers' income. The objective of this study was to compare the productivity performance of common bean Carioca - IAC Alvorada with irrigation suppression in each of the five phenological phases. The experiment was conducted in plots in a greenhouse at College of Agronomical Sciences, São Paulo State University (UNESP), Botucatu - SP. The hypothesis is that if the water supply is suppressed in one of the five development stages of irrigated common beans, the yield reduction would be at least 20%. The treatments consisted of suppression irrigation in one of the five development stages (stage V1 to V3, stage V4 to early flowering, flowering stage, pod formation stage and pod filling stage) compared with the irrigation at all stages and suppression of irrigation at all stages, with seven treatments and four replications. The treatments most affected by water suppression were those which suffered suppression of irrigation during the vegetative phase and flowering stage. Treatments with water suppression in all stages, and suppression during the phases (stage V1 to V3, stage V4 to early flowering, flowering stage, pod formation stage and pod filling stage) showed yield reduction of approximately 95%, 55.1%, 49.5%, 63,1%, 30.2% and 35.6%, respectively, when compared to treatment with irrigation all stages. All treatments considered confirmed the hypothesis.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fluoride levels in the public water supplies of 40 Brazilian cities were analyzed and classified on the basis of risk/benefit balance. Samples were collected monthly over a seven-year period from three sites for each water supply source. The samples were analyzed in duplicate in the laboratory of the Center for Research in Public Health - UNESP using an ion analyzer coupled to a fluoride-specific electrode. A total of 19,533 samples were analyzed, of which 18,847 were artificially fluoridated and 686 were not artificially fluoridated. In samples from cities performing water fluoridation, 51.57% (n=9,720) had fluoride levels in the range of 0.55 to 0.84 mg F/L; 30.53% (n=5,754) were below 0.55 mg F/L and 17.90% (n=3,373) were above 0.84 mg F/L (maximum concentration=6.96 mg F/L). Most of the cities performing fluoridation that had a majority of samples with fluoride levels above the recommended parameter had deep wells and more than one source of water supply. There was some variability in the fluoride levels of samples from the same site and between collection sites in the same city. The majority of samples from cities performing fluoridation had fluoride levels within the range that provides the best combination of risks and benefits, minimizing the risk of dental fluorosis while preventing dental caries. The conduction of studies about water distribution systems is suggested in cities with high natural fluoride concentrations in order to optimize the use of natural fluoride for fluoridation costs and avoid the risk of dental fluorosis.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Geociências e Meio Ambiente - IGCE

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Ciências Biológicas (Biologia Celular e Molecular) - IBRC

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil - FEIS

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Groundwater in the Rio Claro district is predominantly extracted from low productivity wells on the Itararé Aquifer, from depths greater than 150 m. These factors in conjunction with increasing demand for water supply have stimulated many industries to exploit the Rio Claro Aquifer, constituted by Cenozoic sediments of the Rio Claro Formation, where hydraulic properties are poorly known. For this reason, it is necessary to study the possible vulnerable to contamination punctual locations of the aquifer, in order to enable proper management of these groundwater reserves and to allow continuity of supply. Thus, this study aims to assess the vulnerability to groundwater on contamination Rio Claro Aquifer, punctually in Mandu mining site area, located in the District of Ajapi, Rio Claro - SP, the company which operates and sells industrial sand. The risk of groundwater contamination depends on the relationship between the hydrogeological characteristics of the aquifer layer (vulnerability to contamination) and the pollutant load. To evaluate the susceptibility to contamination it was applied the method GOD (FOSTER and HIRATA, 1987; FOSTER et. al., 2002) and, in addition, field and laboratory tests were performed to chacacterize the granulometry of the strata, hydraulic conductivity and some physical indices to make the evaluation more assertive and detailed. Punctual contamination vulnerability found in the aquifer Rio Claro, was moderate, which means that the aquifer is vulnerable to some contaminants, but when continuously discharged or leached. Thus, Mandu mining has a great role on preventing the emission of contaminants in the process of extraction and processing of sand... (Complete abstract click electronic access below)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The growing interest in the use of groundwater resources is directly related to the economic advantages that the groundwater exploitation offers when compared to surface waters. This happens especially in large urban centers, such as the city of Americana / SP, where the rivers are increasingly contaminated by household and industrial waste. Therefore, this study aimed to characterize the Tubarão Aquifer System, in the city of Americana, to identify and evaluate the spatial distribution of different hydrogeochemical facies as well as understand the rock-fluid interaction through the construction of a conceptual hydrogeochemical model. This study was made based on the recognition of the possible chemical reactions that print the chemical characteristics of groundwater in the area. To do the job, there were two water sampling campaigns of all deep wells used by the City of Americana public water supply. From the results of hydrochemical, classification of water was made by Piper and Stiff diagrams as well as geostatistical data using cluster analysis of principal components. Based on information from the profiles obtained from the survey SIAGAS as well as in geological profiles provided by the city of Americana, we sought to detail the subsurface geology of the Subgroup Itararé in the city of Americana. The results obtained allowed the identification of three hydrochemical types in the study area: Bicarbonated calcium-sodium (1), bicarbonate sodium (2) and sodium chloride (3). The waters have bicarbonate alkaline pH to alkaline and can be considered weakly saline, with electrical conductivity values of around 161 mS / cm. Samples classified as sodium bicarbonate average of 174.99 mS / cm. The pH values ranging from 6.74 to 7.99, averaging 7.52. For the group of waters classified as sodium chloride, conductivity average is 164.32 mS / cm and pH values ranging... (Complete abstract click electronic access below)