35 resultados para Hand Hygiene


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The main function of the mucociliary system is the removal of particles or substances that are potentially harmful to the respiratory tract. The tuning fork therapeutic for the purpose of bronchial hygiene has still not been described in the literature. The optimal vibration frequency to mobilize secretions is widely debated and varies between 3 and 25 Hz. It is expected that a tuning fork is able to generate vibrations in the thorax, facilitating bronchial hygiene. The aim of the present study is to develop tuning forks with different frequencies, for use in bronchopulmonary hygiene therapy. Methods: The first tuning fork was made with a fixed frequency of 25 Hz and it was recorded in the Brazilian institution of patent registration. This device generated a frequency of 25 Hz and had a weight of 521 g, with dimensions of 600 mm in total length. The device is characterized by a bottom end containing a transducer with a diameter of 62 mm and a thickness of 5/16 mm (8''), a rod removable 148 mm, fork length of 362 mm and an extension at the upper end of sinuous shape bilaterally.The tuning forks must be applied at an angle of 90° directly on the chest wall of the patient after pulmonary auscultation for location of secretions. The tuning fork is activated by squeezing the tips of the extensions together and releasing them in a sudden movement. Results: This study shows the result of the development of others three tuning forks of different dimensions to generate different frequencies. Each equipment reaches a fixed frequency preset of 12, 15 and 20 Hz measured by digital oscilloscope. Conclusions: The tuning fork models developed in this study generated different frequencies proposed by the scientific literature as effective in the mobilization of pulmonary secretions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Developmental Dyslexia negatively affects children's reading and writing ability and, in most cases, performance in sensorimotor tasks. These deficits have been associated with structural and functional alterations in the cerebellum and the posterior parietal cortex (PPC). Both neural structures are active during visually guided force control and in the coordination of load force (LF) and grip force (GF) during manipulation tasks. Surprisingly, both phenomena have not been investigated in dyslexic children. Therefore, the aim of this study was to compare dyslexic and non-dyslexic children regarding their visuomotor processing ability and GF-LF coordination during a static manipulation task. Thirteen dyslexic (8-14YO) and 13 age- and sex-matched non-dyslexic (control) children participated in the study. They were asked to grasp a fixed instrumented handle using the tip of all digits and pull the handle upward exerting isometric force to match a ramp-and-hold force profile displayed in a computer monitor. Task performance (i.e., visuomotor coordination) was assessed by RMSE calculated in both ramp and hold phases. GF-LF coordination was assessed by the ratio between GF and LF (GF/LF) calculated at both phases and the maximum value of a cross-correlation function (r(max)) and its respective time lag calculated at ramp phase. The results revealed that the RMSE at both phases was larger in dyslexic than in control children. However, we found that GF/LF, rmax, and time lags were similar between groups. Those findings indicate that dyslexic children have a mild deficit in visuomotor processing but preserved GF-LF coordination. Altogether, these findings suggested that dyslexic children could present mild structural and functional alterations in specific PPC or cerebellum areas that are directly related to visuomotor processing. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to optimize a radiographic technique for hand examinations using a computed radiography (CR) system and demonstrate the potential for dose reductions compared with clinically established technique. An exposure index was generated from the optimized technique to guide operators when imaging hands. Homogeneous and anthropomorphic phantoms that simulated a patient's hand were imaged using a CR system at various tube voltages and current settings (40-55 kVp, 1.25-2.8 mAs), including those used in clinical routines (50 kVp, 2.0 mAs) to obtain an optimized chart. The homogeneous phantom was used to assess objective parameters that are associated with image quality, including the signal difference-to-noise ratio (SdNR), which is used to define a figure of merit (FOM) in the optimization process. The anthropomorphic phantom was used to subjectively evaluate image quality using Visual Grading Analysis (VGA) that was performed by three experienced radiologists. The technique that had the best VGA score and highest FOM was considered the gold standard (GS) in the present study. Image quality, dose and the exposure index that are currently used in the clinical routine for hand examinations in our institution were compared with the GS technique. The effective dose reduction was 67.0%. Good image quality was obtained for both techniques, although the exposure indices were 1.60 and 2.39 for the GS and clinical routine, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Bases Gerais da Cirurgia - FMB

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)