52 resultados para HEAT EXCHANGER EFFICIENCY


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEB

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study aims to evaluate structurally a heat exchanger that has been in operation since the mid-60's and was built COSAN for operation in one of its sugar production plants in São Paulo, this equipment as well as many similar devices are operation in plants throughout Brazil, and thus to be acquired by large corporations as in the case of COSAN, pass the scrutiny of inspection work, and work such as recalculations in the latter case in structural evaluations to verify the possible need for adjustments to project or operation and thus ensure the structural integrity of the equipment. To this were first done field survey using techniques of NDT and NDT's for determining the thickness of the main parts of the equipment, made the revaluation dimensional and existing project and considering the loads operating performing the characterization of the equipment as specified in the standard regulatory number 13 - NR13 and the other for this type of equipment and finally an analysis using a static approach, as an analysis tool using the finite element method

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study aims to determine the most suitable type of heat exchanger to be applied to the water cooling the mold of a continuous casting process. Basically been studied four types of heat exchangers: shell and tube operating in counterflow, shell and tube operating in parallel flow, plate type and operating counterflow and plates operating in parallel flow. Initially is displayed design of heat exchangers for the conditions of the proposed application. With the heat exchangers dimensioned comparisons were made in order to set the heat exchanger more suitable for application. In the study, one comes to the conclusion that the plate type heat exchangers operating shows counterflow major advantage for this application

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The object of this study is a glass heating machine for rolling process, designed in 2006 and which is manufactured regularly. By customer request it is intended to increase the production capacity of this machine. However, initial tests have shown that the existing heat exchanger cannot supply the necessary thermal energy demand. A study of the thermal characteristics of the equipment was performed in order to obtain the required information to study alternatives for expanding its capacity taking into account space limitations and the need to rationalize costs, avoiding unnecessary oversizing

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study aims to analyze the capacity of a helical coil heat exchanger to reach the requested heat transfer rates by a sodium hypochlorite production process. This heat exchanger was installed in an experimental way in order to reuse a source of low-temperatures water in such a way to become a more economical alternative than the existing cooling tower. Firstly, the concepts related to the theory of heat transfer applicable to the case were introduced. Then, the mapping of the main information about the production process and the technical specification of the current cooling system equipment's was realized. Using the dimensions of the heat exchanger installed today as reference, the calculations for determining the ideal length of the coil to different flows of hot fluid were performed. Finally, it was concluded that the heat exchanger currently employed does not provide heat transfer rates required for the maximum flow rate value supported by the cooling tower

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The modernization of the world made the speed, accuracy and reliability of all existing processes become increasingly necessary. For this evolution to occur every day, the evolution of the equipment was strategic, but not as much as needed. It is necessary for such equipment to ensure its function and, in case of failure, an early diagnosis to prevent loss. Therefore the evolution of maintainability and reliability in equipment is also paramount. Thus, the growth of forms of maintenance was driven by this scenario, forming maintenance philosophies. Among many, there is the RCM, which have its focus on the identification, parameters development and performance preview. One of those methodologies from this idea is the FMEA, process that has been studied and implemented this work, aiming the anticipation of failure modes and guidance for the use of a heat exchanger and a pump. This implementation has the aid of another process of RCM, the PHA, which was also shown and implemented, these results being used to start the FMEA process. The results show the activities with the highest chance of failure, presenting also the measures to be taken to avoid or minimize them. It is shown, in this paper, concern with the valves because they maintain control and system security, and its flaws related to accidents with possible danger to people and the whole system, emphasizing the priority of action

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The increase in the use of natural gas in Brazil has stimulated public and private sectors to analyse the possibility of using combined cycle systems for generation of electrical energy. Gas turbine combined cycle power plants are becoming increasingly common due to their high efficiency, short lead times, and ability to meet environmental standards. Power is produced in a generator linked directly to the gas turbine. The gas turbine exhaust gases are sent to a heat recovery steam generator to produce superheated steam that can be used in a steam turbine to produce additional power. In this paper a comparative study between a 1000 MW combined cycle power plant and 1000 kW diesel power plant is presented. In first step, the energetic situation in Brazil, the needs of the electric sector modification and the needs of demand management and integrated means planning are clarified. In another step the characteristics of large and small thermoelectric power plants that use natural gas and diesel fuel, respectively, are presented. The ecological efficiency levels of each type of power plant is considered in the discussion, presenting the emissions of particulate material, sulphur dioxide (SO2), carbon dioxide (CO2) and nitrogen oxides (NOx). (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work aims with an approach for cogeneration plants evaluation based on thermoeconomic functional diagram analysis. The second law of thermodynamics is used to develop a methodology to analyse cogeneration systems, based on exergoeconomics evaluation. The thermoeconomic optimisation method developed is applied to allow a better configuration of the cogeneration plant associated to a university hospital. Also ecological efficiency is evaluated. The method was efficient and contributes for thermoeconomics modelling and analysis and can be applied to any sort of thermal system, especially those with combined heat and power in thermal parity. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper evaluates and quantifies the environmental impact resulting from the combination of biodiesel fuel (pure or blended with diesel), and diesel combustion in thermoelectric power plants that utilize combined cycle technology (CC). In regions without natural gas, the option was to utilize diesel fuel; the consequence would be a greater emission of pollutants. Biodiesel is a renewable fuel which has been considerably interesting in Brazil power matrix in recent years. The concept of ecological efficiency, largely evaluates the environmental impact caused by CO(2), SO(2), NO(x) and particle matter (PM) emissions. The pollution resulting from biodiesel and diesel combustion is analyzed, separately considering CO(2), SO(2), NO(x) and particulate matter gas emissions, and comparing them international standards currently used regarding air quality. It can be concluded that it is possible to calculate the qualitative environmental factor, and the ecological effect, from a thermoelectric power plant utilizing central heat power (CHP) of combined cycle. The ecological efficiency for pure biodiesel fuel (B100) is 98.16%; for biodiesel blended with conventional diesel fuel, B20 (20% biodiesel and 80% diesel) is 93.19%. Finally, ecological efficiency for conventional diesel is 92.18%, as long as a thermal efficiency of 55% for thermoelectric power plants occurs. Crown Copyright (C) 2009 Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)