51 resultados para Ground control lines
Resumo:
MCF-7 (estrogen receptor positive - ER(+)) and MDA-MB-231 (estrogen receptor negative - ER(-)) are human breast cancer cell lines which express functional thyroid hormone receptors (c-erb A alpha 1 and c-erb beta 1) as indicated by stimulation of mitochondrial alpha-glycerophosphate dehydrogenase. In MCF-7, mimicking E(2), T-3 stimulated growth in a dose-dependent (10(10) M-10(-8) M) manner, induced the expression of progesterone receptor and growth factor TGF alpha mRNAs and inhibited that of TGF beta mRNA; T-3 also increased progesterone binding and LDH5 isozyme activities. None of these effects were observed in (ER(-)) MDA-MB-231 cells. 10(-6) M tamoxifen (TAM) reverted growth stimulation, suppressed progesterone receptor and TGF alpha mRNA induction and restored TGF beta mRNA to control levels in T-3-treated MCF-7 cells. That T-3 is acting in MCF-7 cells via its binding to ER is suggested by the immunoprecipitation of pre-bound I-125-T-3 from MCF-7 nuclear extracts by an ER-specific monoclonal antibody and by the displacement of H-3-estradiol binding to ER by radioinert T-3. Copyright (C) 1996 Elsevier B.V. Ltd.
Resumo:
Initially this paper shows the ground wire reduction process for generic multiphase transmission lines and after, the ground wire reduction process for a specilic 440-kV three-phase overhead transmission line. Following this, the influence of the ground wire reduction process considering two situations is shown: first, considering frequency independence and second, when these parameters are considered as frequency dependent. This paper presents analytical results for generic multiphase transmission lines. For a specific 440-kV three-phase overhead transmission line, analytical and graphic results are shown considering real data for every frequency between 10 Hz and 1 MHz.
Resumo:
The results presented in this paper are based on a research about the application of approximated transformation matrices for electromagnetic transient analyses and simulations in transmission lines. Initially, it has developed the application of a single real transformation matrix for a double three-phase transmission lines, because the symmetry of the distribution of the phase conductors and the ground wires. After this, the same type of transformation matrix has applied for symmetrical single three-phase transmission lines. Analyzing asymmetrical single three-phase lines, it has used three different line configurations. For these transmission line types, the errors between the eigenvalues and the approximated results, called quasi modes, have been considered negligible. on the other hand, the quasi mode eigenvalue matrix for each case was not a diagonal one. and the relative values of the off-diagonal elements of the approximated quasi mode matrix are not negligible, mainly for the low frequencies. Based on this problem, a correction procedure has been applied for minimizing the mentioned relative values. For the correction procedure application, symmetrical and asymmetrical single three-phase transmission line samples have been used. Checking the correction procedure results, analyses and simulations have been carried out in mode and time domain. In this paper, the last results of mentioned research are presented and they related to the time domain simulations.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A model for preventive control in electrical systems is presented, taking into account the dynamic aspects of the network. Among these aspects, the effects provoked by perturbations which cause oscillations in synchronous machine angles (transient stability), such as electric equipment outages and short circuits, are presented. The energy function is used to measure the stability of the system using a procedure defined as the security margin. The control actions employed are load shedding and generation reallocation. An application of the methodology to a system located in southern Brazil, which is composed of 10 synchronous machines, 45 busses, and 72 transmission lines. The results confirm the theoretical studies.
Resumo:
5-azacytidine (5-azaC) treatment combined with cytosine arabinoside (ara-C) or caffeine were performed in vitro in Chinese hamster cells, CHO-K1 (wild-type) and xrs-5 (mutant) cell lines, in order to compare the cell response to the induction of chromosomal aberrations. Exponentially growing cells were treated with 5-azaC (4-16 uM) for 1 h, the cells were washed and incubated for 7 h, and 500 uM caffeine or 5 uM ara-C were added to the cultures for the last 2 h. In both cell lines, 5-azaC induced a significantly increase (P<0.01) in the frequencies of aberrations; in the combined treatments (5-azaC + Ara-C), a significant reduction (P<0.05) was observed for the aberrations which were randomly distributed. Caffeine had no influence at the same conditions. 5-azaC induced-DNA lesions were probably processed at S/G2 phase in a common pathway in both cell lines, but alternatively, 5-azaC may cause xrs-5 cells to revert to the wild-type.
Resumo:
In order to evaluate the use of shallow seismic technique to delineate geological and geotechnical features up to 40 meters depth in noisy urban areas covered with asphalt pavement, five survey lines were conducted in the metropolitan area of São Paulo City. The data were acquired using a 24-bit, 24-channel seismograph, 30 and 100 Hz geophones and a sledgehammer-plate system as seismic source. Seismic reflection data were recorded using a CMP (common mid point) acquisition method. The processing routine consisted of: prestack band-pass filtering (90-250 Hz); automatic gain control (AGC); muting (digital zeroin) of dead/noisy traces, ground roll, air-wave and refracted-wave; CMP sorting; velocity analyses; normal move-out corrections; residual static corrections; f-k filtering; CMP stacking. The near surface is geologically characterized by unconsolidated fill materials and Quaternary sediments with organic material overlying Tertiary sediments with the water table 2 to 5 m below the surface. The basement is composed of granite and gneiss. Reflections were observed from 40 milliseconds to 65 ms two-way traveltime and were related to the silt clay layer and fine sand layer contact of the Tertiary sediments and to the weathered basement. The CMP seismic-reflection technique has been shown to be useful for mapping the sedimentary layers and the bedrock of the São Paulo sedimentary basin for the purposes of shallow investigations related to engineering problems. In spite of the strong cultural noise observed in these urban areas and problems with planting geophones we verified that, with the proper equipment, field parameters and particularly great care in data collection and processing, we can overcome the adverse field conditions and to image reflections from layers as shallow as 20 meters.
Resumo:
The objective of this paper is to show an alternative representation in time domain of a non-transposed three-phase transmission line decomposed in its exact modes by using two transformation matrices. The first matrix is Clarke's matrix that is real, frequency independent, easily represented in computational transient programs (EMTP) and separates the line into Quasi-modes α, β and zero. After that, Quasi-modes a and zero are decomposed into their exact modes by using a modal transformation matrix whose elements can be synthesized in time domain through standard curve-fitting techniques. The main advantage of this alternative representation is to reduce the processing time because a frequency dependent modal transformation matrix of a three-phase line has nine elements to be represented in time domain while a modal transformation matrix of a two-phase line has only four elements. This paper shows modal decomposition process and eigenvectors of a non-transposed three-phase line with a vertical symmetry plane whose nominal voltage is 440 kV and line length is 500 km. ©2006 IEEE.
Resumo:
The paper shows an alternative methodology to calculate transmission line parameters per unit length and to apply it in a three-phase line with a vertical symmetry plane. This procedure is derived from a general procedure where the modal transformation matrix of the line is required. In this paper, the unknown modal transformation matrix requested by general procedure is substituted by Clarke's matrix. With the substitution that is shown in the paper, the transmission line parameters can be obtained starting from impedances measured in one terminal of the line. First, the article shows the classical methodology to calculate frequency dependent transmission line parameters by using Carson and Pollaczeck's equations for representing the ground effect and Bessel's functions to represent the skin effect. After that, a new procedure is shown to calculate frequency dependent transmission line parameters directly from currents and voltages of an existing line. Then, this procedure is applied in a non-transposed three-phase transmission line whose parameters have been previously calculated by using the classical methodology. Finally, the results obtained by using the new procedure and by using the classical methodology are compared. The article shows simulation results for typical frequency spectra of switching transients (10 Hz to 10 kHz). Results have shown that procedure has © 2006 IEEE.
Resumo:
The restructuring of energy markets to provide free access to the networks and the consequent increase of the number of power transactions has been causing congestions in transmission systems. As consequence, the networks suffer overloads in a more frequent way. One parameter that has strong influence on transfer capability is the reactive power flow. A sensitivity analysis can be used to find the best solution to minimize the reactive power flows and relief, the overload in one transmission line. The proposed methodology consists on the computation of two sensitivities based on the use of the Lc matrix from CRIC (Constant Reactive Implicitly Coupled) power flow method, that provide a set of actions to reduce the reactive power flow and alleviate overloads in the lines: (a) sensitivity between reactive power flow in lines and reactive power injections in the buses, (b) sensitivity between reactive power flow in lines and transformer's taps. © 2006 IEEE.
Resumo:
In a general way, in an electric power utility the current transformers (CT) are used to measurement and protection of transmission lines (TL) 1 The Power Line Carriers systems (PLC) are used for communication between electrical substations and transmission line protection. However, with the increasing use of optical fiber to communication (due mainly to its high data transmission rate and low signal-noise relation) this application loses potentiality. Therefore, other functions must be defined to equipments that are still in using, one of them is detecting faults (short-circuits) and transmission lines insulator strings damages 2. The purpose of this paper is to verify the possibility of using the path to the ground offered by the CTs instead of capacitive couplings / capacitive potential transformers to detect damaged insulators, since the current transformers are always present in all transmission lines (TL's) bays. To this a comparison between this new proposal and the PLC previous proposed system 2 is shown, evaluating the economical and technical points of view. ©2010 IEEE.
Resumo:
Nine ruminally cannulated cows fed different energy sources were used to evaluate an avianderived polyclonal antibody preparation against specific ruminal bacteria and monensin on microbial community diversity. The experimental design was three Latin squares 3 x 3 distinguished by the main energy source in the diet [dry-ground corn grain, high moisture corn silage or citrus pulp]. Inside each Latin square, animals received one of the feed additives per period [control, monensin or polyclonal antibody preparation]. Each period lasted 21 days where 20 were used for treatments adaptation and the last one for sampling collection. Microbial diversity was evaluated by protozoa counts and denaturing gradient gel electrophoresis. Polyclonal antibodies plus citrus pulp (CiPu) addition in the diet resulted in an increase of relative counting of Isotricha protozoa that indicates a possible effect on this ruminal ciliate population. In general lines, in the present experiment, it was not possible to assign that there was a pattern in the structures of amplification of Bacteria and Archaea communities of the ruminal content. Oral passive immunization is a technology that arises as an effective alternative for feed additive production. Further research is still necessary to better understand its mechanisms of action.
Resumo:
This paper presents a method for analyzing electromagnetic transients using real transformation matrices in three-phase systems considering the presence of ground wires. So, for the Z and Y matrices that represent the transmission line, the characteristics of ground wires are not implied in the values related to the phases. A first approach uses a real transformation matrix for the entire frequency range considered in this case. This transformation matrix is an approximation to the exact transformation matrix. For those elements related to the phases of the considered system, the transformation matrix is composed of the elements of Clarke's matrix. In part related to the ground wires, the elements of the transformation matrix must establish a relationship with the elements of the phases considering the establishment of a single homopolar reference in the mode domain. In the case of three-phase lines with the presence of two ground wires, it is unable to get the full diagonalization of the matrices Z and Y in the mode domain. This leads to the second proposal for the composition of real transformation matrix: obtain such transformation matrix from the multiplication of two real and constant matrices. In this case, the inclusion of a second matrix had the objective to minimize errors from the first proposal for the composition of the transformation matrix mentioned. © 2012 IEEE.
Resumo:
To investigate morphological and genomic differences between cutting and racing lines of Quarter Horses, 120 racing and 68 cutting animals of both sexes, registered at the Brazilian Association of Quarter Horse Breeders, were used. Blood samples were collected, and the following physical traits were measured: weight; height at withers; body length; length of the shank, pastern, rump, head, and neck; and chest, shank, and hoof circumference. For analysis of genomic differences, 54,602 single-nucleotide polymorphisms (SNPs) were genotyped using the Equine SNP50 BeadChip, and the quality of individual and SNP genotype data were evaluated. The fixation index, FST, was used to identify genome regions that were altered in the lines by selection. The results showed significant differences between the lines in all physical traits. Quality control led to the exclusion of four cutting animals with a call rate of <0.95. After filtering, 12,544, 13,815, and 13,370 SNPs were excluded for the whole population (n = 184), the 120 racing animals, and the 64 cutting animals, respectively. The number of informative polymorphisms detected in each line and in the whole population indicated that the Equine SNP50 BeadChip can be used in genetic studies of Quarter Horses. The fixation index, FST, identified 2,558 genome regions that may have been modified by divergent selection. © 2013 Elsevier Inc.
Resumo:
The objective was to evaluate reproductive tract development (ovary and uterus) and onset of puberty in two lines of Nellore heifers (Bos indicus) selected for postweaning weight. A total of 123 heifers, including 46 from the control Nellore line (NeC) and 77 from the selection Nellore line (NeS) were used. Every 18 to 21 days from 12 to 24 months of age, average ovarian area (OVA), endometrial thickness (ETh), and diameter of the largest follicle in each ovary were evaluated (using transrectal ultrasonography), and body weight, hip height, and body condition score were measured. There were no differences between NeS and NeC heifers for ETh or OVA (P < 0.05). Genetic selection for higher postweaning weight had no negative influence on the onset of puberty, with 52% and 48% of NeC and NeS heifers, respectively, pubertal at 24 months of age (P = 0.49). Heifers that reached puberty at the end of the study were heavier (NeC, 296.9 vs. 276.7 kg; NeS, 343.5 vs. 327.9 kg; P < 0.01) and younger (NeC, 23.4 vs. 24.2 mo; NeS, 22.7 vs. 24.0 months; P < 0.01) than those that did not. Furthermore, heifers that were heavier at weaning reached puberty earlier. Pubertal heifers had a greater OVA (4.15 vs. 3.14 cm2; P < 0.01) and ETh (12.15 vs. 9.93 mm; P < 0.01) than nonpubertal heifers. Taken together, OVA and ETh had positive effects (P < 0.01) on the onset of puberty and were suitable indicator traits of heifer sexual precocity in pasture management systems. However, selection for weight did not alter ovarian or endometrial development, or manifestation of puberty at 24 months of age. Among the growth traits studied, weaning weight and weight at puberty had significant positive effects on manifestation of first estrus. © 2013 Elsevier Inc.