40 resultados para Fire engines


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: The effects of fire ensure that large areas of the seasonal tropics are maintained as savannas. The advance of forests into these areas depends on shifts in species composition and the presence of sufficient nutrients. Predicting such transitions, however, is difficult due to a poor understanding of the nutrient stocks required for different combinations of species to resist and suppress fires. Methods: We compare the amounts of nutrients required by congeneric savanna and forest trees to reach two thresholds of establishment and maintenance: that of fire resistance, after which individual trees are large enough to survive fires, and that of fire suppression, after which the collective tree canopy is dense enough to minimize understory growth, thereby arresting the spread of fire. We further calculate the arboreal and soil nutrient stocks of savannas, to determine if these are sufficient to support the expansion of forests following initial establishment. Results: Forest species require a larger nutrient supply to resist fires than savanna species, which are better able to reach a fire-resistant size under nutrient limitation. However, forest species require a lower nutrient supply to attain closed canopies and suppress fires; therefore, the ingression of forest trees into savannas facilitates the transition to forest. Savannas have sufficient N, K, and Mg, but require additional P and Ca to build high-biomass forests and allow full forest expansion following establishment. Conclusions: Tradeoffs between nutrient requirements and adaptations to fire reinforce savanna and forest as alternate stable states, explaining the long-term persistence of vegetation mosaics in the seasonal tropics. Low-fertility limits the advance of forests into savannas, but the ingression of forest species favors the formation of non-flammable states, increasing fertility and promoting forest expansion. © 2013 Springer Science+Business Media Dordrecht.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multisensor data fusion is a technique that combines the readings of multiple sensors to detect some phenomenon. Data fusion applications are numerous and they can be used in smart buildings, environment monitoring, industry and defense applications. The main goal of multisensor data fusion is to minimize false alarms and maximize the probability of detection based on the detection of multiple sensors. In this paper a local data fusion algorithm based on luminosity, temperature and flame for fire detection is presented. The data fusion approach was embedded in a low cost mobile robot. The prototype test validation has indicated that our approach can detect fire occurrence. Moreover, the low cost project allow the development of robots that could be discarded in their fire detection missions. © 2013 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present article is to assess and compare the performance of electricity generation systems integrated with downdraft biomass gasifiers for distributed power generation. A model for estimating the electric power generation of internal combustion engines and gas turbines powered by syngas was developed. First, the model determines the syngas composition and the lower heating value; and second, these data are used to evaluate power generation in Otto, Diesel, and Brayton cycles. Four synthesis gas compositions were tested for gasification with: air; pure oxygen; 60% oxygen with 40% steam; and 60% air with 40% steam. The results show a maximum power ratio of 0.567 kWh/Nm(3) for the gas turbine system, 0.647 kWh/Nm(3) for the compression ignition engine, and 0.775 kWh/Nm(3) for the spark-ignition engine while running on synthesis gas which was produced using pure oxygen as gasification agent. When these three systems run on synthesis gas produced using atmospheric air as gasification agent, the maximum power ratios were 0.274 kWh/Nm(3) for the gas turbine system, 0.302 kWh/Nm(3) for CIE, and 0.282 kWh/Nm(3) for SIE. The relationship between power output and synthesis gas flow variations is presented as is the dependence of efficiency on compression ratios. Since the maximum attainable power ratio of CIE is higher than that of SIE for gasification with air, more research should be performed on utilization of synthesis gas in CIE. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Species from the Solenopsis saevissima (Smith) (Hymenoptera: Formicidae) species group are native to South America and have a cosmopolitan distribution because they have been accidentally introduced in many countries around the world. In Brazil, they have a wide distribution, including urban areas. The present study was conducted to investigate the characterization of Solenopsis genus populations associated with urban/human interference sites in Brazil by analyzing the mitochondrial gene cytochrome oxidase I and estimating the degree of relatedness of these populations to make inferences about their phylogeny and also observe the patterns of mitochondrial haplotype (mitotype) distribution across their range. The results revealed complete geographical coherence and polyphyly for the Solenopsis invicta Buren and Solenopsis saevissima species groups, which confirms the diversity of the genera. It also suggests the possibility that reproductively-isolated populations occur, resulting in the evolutionary process of speciation. No predominant haplotype was found in the populations analyzed, but some were more prevalent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

QuestionsWe aimed to analyse the effect of fire on flowering in subtropical grasslands, by addressing the following questions: will fire history affect flowering? If yes, do fire feedbacks influence flowering or is it just the removal of above-ground biomass? Are there differences in burned and mowed plots?LocationSubtropical grasslands in Southern Brazil (30 degrees 03S, 51 degrees 07W).MethodsWe established plots in areas with different fire histories: 30d (30 plots: five replicates), 1yr (14 replicates), 3yr (30 plots: five replicates) since the last fire, in experimentally burned and mowed plots (14 replicates each). We counted the number of flowering species, as well as the number of flowering stalks.ResultsGraminoid species flowered in highest numbers 1yr after fire, whilst forbs had more species flowering just after fire, indicating different reproductive strategies in post-fire environments. Mowing was not as efficient as fire in stimulating flowering. Finally, the different functional groups showed different flowering responses to time since last fire and to the different types of management.ConclusionsOur results show fire stimulated flowering. Although mowing can be a good alternative for maintaining plant diversity, our study showed that this practice is not as efficient as fire in stimulating flowering. However, fire season should be noted as a limiting factor to the recovery of C-3 grasses in these subtropical grasslands, and annual burns may be harmful to C-4 grasses, since they delay their flowering to the next post-fire growing season.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work has the purpose to explain how the sugar and alcohol sector works, detail all the processes which uses pumps and assist in the selection and specification of pumps attached with engines, that will make part in important industry processes in the manufacture of sugar and alcohol. A bibliographic revision about the working of sugar and alcohol sector and about pumps were made to help the analysis of a case. This case had the purpose to analyze the selected pumps that were part of a initial project of an industry which aimed a future expansion. The pumps that were selected to made part of the initial project were over dimensioned and were operating out of the best performance point, making the pumps inefficient because the expansion didn't happened. The solution was to select another pump with bigger performance and less power consumption to have a decrease in the energy consumption and in the operational costs of the industry and using the extra electric energy in the industry or selling it

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)