51 resultados para Fire Extinguishing Equipment.
Resumo:
Biomass consumption and carbon release rates during the process of forest clearing by fire in five test plots are presented and discussed. The experiments were conducted at the Caiabi Farm near the town of Alta Floresta, state of Mato Grosso, Brazil, in five square plots of 1 ha each designated A, B, C, D, and E, with different locations and timing of fire. Plot A was located in the interface with a pasture, with three edges bordering on the forest, and was cut and burned in 1997. Plots B,C, D, and E were located inside the forest. Plot B was cut and burned in 1997. Plot C was inside a deforested 9-ha area, which was cut and burned in 1998. Plot D was inside a deforested 4-ha area, which was cut in 1998 and burned in 1999. Plot E was inside a deforested 4-ha area which was cut and burned in 1999. Biomass consumption was 22.7%, 19.5%, 47.5%, 61.5% and 41.8%, for A, B, C, D, and E, respectively. The effects of an extended curing period and of increasing the deforested area surrounding the plots could be clearly observed. The consumption for areas cut and burned during the same year, tended toward a value of nearly 50% when presented as a function of the total area burned. The aboveground biomass of the test site and the amount of carbon before the fire were 496 Mg ha-1 and 138 Mg ha-1, respectively. Considering that the biomass that remains unburned keeps about the same average carbon content of fresh biomass, which is supported by the fact that the unburned material consists mainly of large logs and considering the value of 50% for consumption, the amount of carbon released to the atmosphere as gases was 69 Mg ha-1. The amounts of CO2 and CO released to the atmosphere by the burning process were then estimated as 228 Mg ha-1 and 15.9 Mg ha-1, respectively. Observations on fire propagation and general features of the slash burnings in the test areas complete the paper. Copyright 2001 by the American Geophysical Union.
Resumo:
The double pulley equipment was tested on ten male volunteers during contraction of the semitendinosus and biceps femoris (caput longum) muscles in the following movements of the lower limbs: 1) hip extension with extended knee and erect trunk, 2) hip extension with flexed knee and erect trunk, 3) hip extension with flexed knee and erect trunk, 3) hip extension with extended knee and inclined trunk, 5) hip abduction along the midline, 7) hip abduction with extension beyond the midline, 8) adduction with hip flexion beyond the midline, 8) adduction with hip flexion beyond the midline, and 9) adduction with hip extension beyond the midline. The myoelectric signals were taken up by Lec Tec surface electrodes connected to a 6-channel Lynx electromyographic signal amplifier coupled with a computer equipped with a model CAD 10/26 analogue digital conversion board and with a specific software for signal recording and analysis. The semitendinosus and biceps femoris muscles presented the highest potentials in movements 1; 2; 7, 8 and 9, whereas the potentials in the remaining movements were negligible. The pattern of activity of the semitendinosus and the biceps femoris was similar in exercises 1, 2, 3, 4 and 8. The potentials of the semitendinosus prevailed in movements 5, 6 and 7, and the strongest potentials observed in movement 9 were those of the biceps femoris.
Resumo:
It was evaluated movements of lower limb in the double pulley system equipment on ten male volunteers during contraction of gastrocnemius (caput laterale ) and gluteus maximus muscles in the following movements: 1) hip extension with extended knee and erect trunk, 2) hip extension with flexed knee and erect trunk, 3) hip extension with flexed knee and erect trunk, 3) hip extension with extended knee and inclined trunk, 5) hip abduction along the midline, 7) hip abduction with extension beyond the midline, 8) adduction with hip flexion beyond the midline, 8) adduction with hip flexion beyond the midline, and 9) adduction with hip extension beyond the midline. Myoelectric signals were taken up by Lec Tec surface electrodes connected to a 6-channel Lynx electromyographic signal amplifier coupled with a computer equipped with a model CAD 10/26 analogue digital conversion board and with a specific software for signal recording and analysis. We observed weak gastrocnemius muscle activity for all movements studied. In the case of gluteus maximus, the most important potentials were observed for movement 2, while for the remaining movements the actions were of reasonable intensity. Compared to gluteus, gastrocnemius was less required for all movements.
Resumo:
There are several difficulties in the control of quick spreading and highly contagious poultry diseases such as avian influenza and Newcastle disease, which require large numbers of poultry to be rapidly killed inside the poultry houses in order to minimize human exposure and disease spreading. We have built and tested an equipment that uses a waterbased foam from high expansion fire detergent that induces poultry anoxia measured by sensorial signs, time to death, lethality and macro and microscopically lesions. Two hundred 78-weeks old hens were divided into ten groups and exposed to different times of death according to exposure to water-foam varying from 5min30s to 8min15s. All poultry died after six minutes of water-foam cover. Foam bubbles were observed in oral cavity and trachea of all poultry at each time of exposure to foam, revealing physical asphyxia. Macroscopically, congestion in oral cavity and in trachea mucosa was observed. Histopathology revealed diffuse and moderate hemorrhage in lungs and no lesion in trachea. The efficacy of water-foam procedure for poultry depopulation was demonstrated validating its recommendation in case of emergency.
Resumo:
Although common in Brazil, the biology of the fire ant Solenopsis saevissima (Smith) is still poorly studied. Larval descriptions are useful to genus-level ant systematics and sometimes to species-level taxonomy. This study presents a detailed description of juveniles of S. saevissima from Brazil, which were compared with Brazilian specimens of Solenopsis invicta Buren, Solenopsis geminata (Fabricius), and Solenopsis altipunctata Pitts. Different larval instars were separated by diagnostic morphological traits which were confirmed by observing moults. Reproductive larvae could be easily sorted by their distinctive body dimensions and shape. Contrary to previous reports on this species, the larvae of S. saevissima proved to be generally identical to those of S. invicta, while a few specimens resembled those of other close species, such as Solenopsis megergates Trager. Mature larvae thus presented considerable intraspecific variation in some characters recently proposed to aid fire ant species separation (morphology of head hairs). © 2012 Eduardo Gonalves Paterson Fox et al.
Resumo:
Fire ants are aggressive Neotropical ants that are extensively similar in general biology and morphology, making species identification difficult. Some fire ant species are top-rated pests spreading throughout the world by trade vessels. Many researchers attempted to sort between invasive and native species by using chemical characters, including patterns of venom alkaloids. The present study is the first to report intraspecific variation in some chemical characters, namely, cuticular hydrocarbons and venom alkaloids, within the Brazilian fire ant species Solenopsis saevissima and also reports on within-nest variations among members of different castes. Two different haplotypes (cryptic species) of S. saevissima were clearly identified, one presenting a predominant combination of the venom alkaloids cis- and trans-2-methyl-6-undecylpiperidine with the cuticular hydrocarbons C23, 3-Me-C23, 10-C 25:1, C25, and 3-Me-C25, and the other a predominant combination of cis- and trans-2-methyl-6-tridecenylpiperidine with predominance of 12-C25:1, C25, 11-Me-C25, 3-Me-C25, 13-C27:1, C27, and 13-Me-C 27. Intranest variations revealed that the proportions among these compounds varied sensibly among workers of different sizes, gynes, and males (no alkaloids were detected in the latter). Larva contained vestiges of the same compounds. The recorded chemical profiles are quite different from previous reports with S. saevissima samples from So Paulo. The finds thus support other recent claims that S. saevissima includes cryptic species; the study, moreover, adds the find that they can occur in the same geographical location. © 2012 Eduardo Gonalves Paterson Fox et al.
Resumo:
The invasive fire ant Solenopsis invicta is medically important because its venom is highly potent. However, almost nothing is known about fire ant venom proteins because obtaining even milligram-amounts of these proteins has been prohibitively challenging. We present a simple and fast method of obtaining whole venom compounds from large quantities of fire ants. For this, we separate the ants are from the nest soil, immerse them in dual-phase mixture of apolar organic solvent and water, and evaporate each solvent phase in separate. The remaining extract from the aqueous phase is largely made up of ant venom proteins. We confirmed this by using 2D gel electrophoresis while also demonstrating that our new approach yields the same proteins obtained by other authors using less efficient traditional methods. © 2013 Elsevier Ltd.
Design of personal protective equipment: To promote of Brazilian artefacts with ergonomic attributes
Resumo:
This research aims to investigate a topic sometimes overlooked among the research of ergonomics. Particularly, we treat the garments as personal protective equipment. In this study we abode on clothing produced and used in Brazil, making notes about the management of occupational safety for the use of such equipment. In turn, identify Relevant requirements for the design of personal protective equipment used in Brazil, in line with what is being studied in global forums on the subject. © 2013 Taylor & Francis Group.
Resumo:
Aims: The effects of fire ensure that large areas of the seasonal tropics are maintained as savannas. The advance of forests into these areas depends on shifts in species composition and the presence of sufficient nutrients. Predicting such transitions, however, is difficult due to a poor understanding of the nutrient stocks required for different combinations of species to resist and suppress fires. Methods: We compare the amounts of nutrients required by congeneric savanna and forest trees to reach two thresholds of establishment and maintenance: that of fire resistance, after which individual trees are large enough to survive fires, and that of fire suppression, after which the collective tree canopy is dense enough to minimize understory growth, thereby arresting the spread of fire. We further calculate the arboreal and soil nutrient stocks of savannas, to determine if these are sufficient to support the expansion of forests following initial establishment. Results: Forest species require a larger nutrient supply to resist fires than savanna species, which are better able to reach a fire-resistant size under nutrient limitation. However, forest species require a lower nutrient supply to attain closed canopies and suppress fires; therefore, the ingression of forest trees into savannas facilitates the transition to forest. Savannas have sufficient N, K, and Mg, but require additional P and Ca to build high-biomass forests and allow full forest expansion following establishment. Conclusions: Tradeoffs between nutrient requirements and adaptations to fire reinforce savanna and forest as alternate stable states, explaining the long-term persistence of vegetation mosaics in the seasonal tropics. Low-fertility limits the advance of forests into savannas, but the ingression of forest species favors the formation of non-flammable states, increasing fertility and promoting forest expansion. © 2013 Springer Science+Business Media Dordrecht.
Resumo:
Multisensor data fusion is a technique that combines the readings of multiple sensors to detect some phenomenon. Data fusion applications are numerous and they can be used in smart buildings, environment monitoring, industry and defense applications. The main goal of multisensor data fusion is to minimize false alarms and maximize the probability of detection based on the detection of multiple sensors. In this paper a local data fusion algorithm based on luminosity, temperature and flame for fire detection is presented. The data fusion approach was embedded in a low cost mobile robot. The prototype test validation has indicated that our approach can detect fire occurrence. Moreover, the low cost project allow the development of robots that could be discarded in their fire detection missions. © 2013 IEEE.
Resumo:
Pós-graduação em Fonoaudiologia - FFC
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Design - FAAC
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)