50 resultados para Fatores hard e soft
Resumo:
Osteodistraction is a clinical reality, available in the last decades for the resolution of large bone deficiencies, in cases that there are pre-existing, but misplaced implants and teeth. The aims of thearticle is to present a case report in which a new possibility for bone distraction, based on tooth-implant bone distractors, made from standard orthodontic expansion-screws, was used in an area where there was an extensive need of alveolar bone and aesthetical recovery, allied to teeth and dental implant misplacement. This technique presented good clinical results, associated to effective simplicity and low cost, becoming viable clinical solution for bone tissue augmentation and aesthetical optimization. In resume, it is possible to say that the suggested technique achieved its objectives, improving the hard and soft tissue profile, whilst allowing completion of oral rehabilitation.
Resumo:
ObjectiveTo compare peri-implant tissue healing at implants installed in sites prepared with conventional drills or a sonic device.Material and methodsIn six Beagle dogs, the mandibular premolars and first molars were extracted bilaterally. After 3 months, full-thickness muco-periosteal flaps were elevated and recipient sites were prepared in both sides of the mandible. In the right side (control), the osteotomies were prepared using conventional drills, while, at the left side (test), a sonic device (Sonosurgery((R))) was used. Two implants were installed in each side of the mandible. After 8weeks of non-submerged healing, biopsies were harvested and ground sections prepared for histological evaluation.ResultsThe time consumed for the osteotomies at the test was more than double compared to the conventional control sites. No statistically significant differences were found for any of the histological variables evaluated for hard and soft tissue dimensions. Although not statistically significant, slightly higher mineralized bone-to-implant contact was found at the test (65.4%) compared to the control (58.1) sites.ConclusionsSimilar healing characteristics in osseointegration and marginal hard tissue remodeling resulted at implants installed into osteotomies prepared with conventional drills or with the sonic instrument (Sonosurgery((R))).
Resumo:
ObjectiveTo compare the sequential healing at immediately loaded implants installed in a healed alveolar bony ridge or immediately after tooth extraction.Material and methodsIn the mandible of 12 dogs, the second premolars were extracted. After 3months, the mesial roots of the third premolars were endodontically treated and the distal roots extracted. Implants were placed immediately into the extraction sockets (test) and in the second premolar region (control). Crowns were applied at the second and third maxillary premolars, and healing abutments of appropriate length were applied at both implants placed in the mandible and adapted to allow occlusal contacts with the crowns in the maxilla. The time of surgery and time of sacrifices were planned in such a way to obtain biopsies representing the healing after 1 and 2weeks and 1 and 3months. Ground sections were prepared for histological analyses.ResultsAt the control sites, a resorption of the buccal bone of 1mm was found after 1week and remained stable thereafter. At the test sites, the resorption was 0.4mm at 1-week period and further loss was observed after 1month. The height of the peri-implant soft tissue was 3.8mm both at test and control sites. Higher values of mineralized bone-to-implant contact and bone density were seen at the controls compared with the test sites. The differences, however, were not statistically significant.ConclusionsDifferent patterns of sequential early healing were found at implants installed in healed alveolar bone or in alveolar sockets immediately after tooth extractions. However, three months after implant installation, no statistically significant differences were found for the hard- and soft-tissue dimensions.
Resumo:
To compare peri-implant soft- and hard-tissue integration at implants installed juxta- or sub-crestally. Furthermore, differences in the hard and soft peri-implant tissue dimensions at sites prepared with drills or sonic instruments were to be evaluated. Three months after tooth extraction in six dogs, recipient sites were prepared in both sides of the mandible using conventional drills or a sonic device (Sonosurgery(®) ). Two implants with a 1.7-mm high-polished neck were installed, one with the rough/smooth surface interface placed at the level of the buccal bony crest (control) and the second placed 1.3 mm deeper (test). After 8 weeks of non-submerged healing, biopsies were harvested and ground sections prepared for histological evaluation. The buccal distances between the abutment/fixture junction (AF) and the most coronal level of osseointegration (B) were 1.6 ± 0.6 and 2.4 ± 0.4 mm; between AF and the top of the bony crest (C), they were 1.4 ± 0.4 and 2.2 ± 0.2 mm at the test and control sites, respectively. The top of the peri-implant mucosa (PM) was located more coronally at the test (1.2 ± 0.6 mm) compared to the control sites (0.6 ± 0.5 mm). However, when the original position of the bony crest was taken into account, a higher bone loss and a more apical position of the peri-implant mucosa resulted at the test sites. The placement of implants into a sub-crestal location resulted in a higher vertical buccal bone resorption and a more apical position of the peri-implant mucosa in relation to the level of the bony crest at implant installation. Moreover, peri-implant hard-tissue dimensions were similar at sites prepared with either drills or Sonosurgery(®) .
Resumo:
Brazil occupies an outstanding position as a producer and exporter of chicken meat, and the maintenance and expansion of this position require a constant evolution, especially in variables which determine quality. An important quality parameter of poultry meat is the amount of water absorbed by the carcass during processing. In Brazil, carcasses chilling is done by immersion in chilled water. In this process, the carcass is rehydrated and the water lost during transport and initial operations is replaced. At this stage, some care is needed to prevent the absorption of water upper than the level allowed by Brazilian law. This project aimed to evaluate extrinsic factors that can influence the absorption of water by the chicken meat. For this, 144 Cobb chickens divided into 24 groups of six birds were used. At 42 days of age, one chicken of each group, with weight ranging up to 10% more or less from the average of the group, was slaughtered in an experimental pilot scale abattoir where slaughter procedures were conducted under strictly controlled conditions. The chilling procedure was performed following a completely randomized design with factorial arrangement 3x2, where the factors were: three temperatures in the first section of the chilling system (4, 10 and 16ºC) and two degrees of water hardness (hard and soft water), with six treatments and four replications. Brazilian law provides that the water temperature in the first section of the chiller must not be higher than 16ºC, and the length of the carcasses in this section shall not exceed 30 minutes. All carcasses remained in the first section of the chiller for 30 minutes and then were transferred to another tank with water at 4ºC, remaining there until reaching 7ºC. The carcasses were weighed before and after chilling, to evaluate the percentage of water absorbed. The water absorption was influenced by the initial temperature of the water in the chiller and by the water hardness. When initially immersed in water at 4ºC, carcasses water absorption averaged 2.70%, a significantly lower absorption than the values found for the carcasses that were initially immersed in water at 16ºC, 3.83% (p<0.05). The carcasses immersed in water at 10ºC had mean water absorption of 3.66%, not differing from the means observed in the other two treatments (p>0.05). In hard water, the average water absorption was 2.46% and, in soft water, 4.33% (p<0.05). In all treatments, the water absorption did not exceed the limit established by Brazilian legislation, which is a maximum of 8%. This information is important to control the absorption of water by carcasses in chicken meat processing, preventing consumers from being harmed.
Resumo:
This case report is an 8-year follow-up of a malpositioned single implant, which was treated with segmental osteotomy, to confirm the treatment's characteristics, indications, and advantages. Deep buccal positioning of an endosseous implant placed in the maxillary left central incisor area did not permit acceptable prosthetic rehabilitation, despite its favorable bone insertion with no significant marginal bone loss. The surgical procedure included osteotomy and block movement performed toward the lingual and cervical position, fixed with a provisional prosthesis and miniplates and mini-implants. A connective tissue graft was necessary for esthetics optimization and was performed in a second stage. Advantages including the prevention of alveolar ridge damage, the improvement of gingival contour, and the use of an already integrated implant are presented. Clinically satisfactory hard and soft tissue stability permitted us to consider segmental surgery as a reliable alternative for malpositioned osseointegrated implants.
Resumo:
Próteses sobre implantes esteticamente favoráveis estão diretamente relacionadas com a condição dos tecidos moles e duros que as envolvem. A preservação dos tecidos mucogengivais ao redor de implantes dentários instalados na maxila anterior propicia um sorriso harmonioso, com uma estética bastante agradável. No entanto, em alguns casos, isso não ocorre principalmente pela grande reabsorção tecidual na região, na qual deveria ter sido realizado enxerto ósseo, antes mesmo da instalação dos implantes. Desse modo, o objetivo deste trabalho foi apresentar uma solução reabilitadora estética para essas possíveis falhas durante o planejamento com reabilitações sobre implantes, por meio de gengiva artificial cerâmica.
Resumo:
This paper concerns a type of rotating machine (centrifugal vibrator), which is supported on a nonlinear spring. This is a nonideal kind of mechanical system. The goal of the present work is to show the striking differences between the cases where we take into account soft and hard spring types. For soft spring, we prove the existence of homoclinic chaos. By using the Melnikov's Method, we show the existence of an interval with the following property: if a certain parameter belongs to this interval, then we have chaotic behavior; otherwise, this does not happen. Furthermore, if we use an appropriate damping coefficient, the chaotic behavior can be avoided. For hard spring, we prove the existence of Hopf's Bifurcation, by using reduction to Center Manifolds and the Bezout Theorem (a classical result about algebraic plane curves).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Forced orthodontic eruption (FOE) is a non-surgical treatment option that allows modifying the osseous and gingival topography. The aim of this article is to present a clinical case of a FOE, which resulted in an improvement of the amount of available bone and soft-tissues for implant site development. Patient was referred for treatment of mobility and unesthetic appearance of their maxillary incisors. Clinical and radiographic examination revealed inflamed gingival tissue, horizontal and vertical tooth mobility and interproximal angular bone defects. It was chosen a multidisciplinary treatment approach using FOE, tooth extraction, and immediate implant placement to achieve better esthetic results. The use of FOE, in periodontally compromised teeth, promoted the formation of a new bone and soft-tissue in a coronal direction, without additional surgical procedures, enabling an esthetic, and functional implant-supported restoration.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this study was to investigate the histological changes that occur in rat soft and hard tissues after Er,Cr:YSGG laser surgery. Each of 20 rats was submitted to four procedures which were randomly distributed to the right and left sides of the animal: procedure 1 dorsal incision with a scalpel; procedure 2 dorsal incision with a 2.0-W Er,Cr:YSGG laser; procedure 3 skull defect created with a diamond bur; procedure 4 skull defect created with a 3.0-W Er,Cr:YSGG laser. The animals were killed 3, 7, 15 and 30 days after surgery, and histological examinations were performed. The histometric analysis of the bone defects was evaluated using an unpaired t-test. Initially, the dorsum showed more histological signs of repair following procedure 1, although similar healing responses following procedures 1 and 2 were seen on day 30 after surgery. By day 30 the bone formation observed following procedure 4 was much more evident than following procedure 3. The unpaired t-test identified significant differences in bone formation on day 30 (p = 0.01), whereas a greater bone percentage was seen following procedure 4 than following procedure 3 (79.96 +/- 10.30% and 58.23 +/- 9.99%, respectively). Thus, histological repair of the Er,Cr:YSGG laser wounds was similar to that of the scalpel wounds. However, skull defects created with the Er,Cr:YSGG laser showed greater bone formation than defects created with the bur. Within the limitations of this study, we can conclude that the Er,Cr:YSGG laser is a promising surgical instrument in vivo, particularly for bone surgery.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)