234 resultados para Enteral feeding tube


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The tick Rhipicephalus sanguineus is a very common parasite of dogs worldwide. Dogs seem unable to acquire resistance against this tick species, whereas guinea pigs demonstrate a very strong resistance following primary infestation. We studied the inflammatory reaction at the R. sanguineus tick feeding site on dogs and guinea pigs during primary and tertiary infestations at different time intervals after attachment. Biopsies were collected after 4, 24, 48 and 96 hours. Changes that were found in all experimental groups included a cone of cement around the mouthparts of the tick, epidermal hyperplasia, edema and inflammatory cell infiltration in the dermis directly underneath the tick attachment site. Dogs reacted to ticks mainly with neutrophils, particularly after repeated exposure. Mast cells and mononuclear leukocytes were also present. Guinea pigs reacted to R. sanguineus mainly with mononuclear cells, eosinophils and basophils. These cells were particularly numerous after repeated exposure to R. sanguineus. Our results suggest that basophils and eosinophils are involved in resistance of guinea pigs to R. sanguineus and that neutrophils in dogs have little effect against this tick species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate the chemical characteristics of the forage and ingestive behavior of Nellore heifers fed hydrolyzed sugarcane in different periods of storage. Twenty-four heifers with initial body weight of 119.6±8.1 kg were utilized. The experimental design was completely randomized, in which the treatments were diets with fresh sugarcane and hydrolyzed sugarcane (5 g of lime kg-1 of chopped sugarcane) stored for 24, 48 or 72 hours as the only roughage. The addition of lime to sugarcane associated with its storage up to 72 hours provided an increase of 20% of the potentially degradable cell wall of carbohydrates, from 382.4 to 458.8 g kg-1 of total carbohydrates. The in vitro digestibility of dry matter was altered by the storage of hydrolyzed sugarcane, increasing 7.08% when the storage time was increased from 24 to 72 hours. Heifers fed fresh sugarcane remained more time consuming compared with heifers fed other diets. The time used for water intake was not influenced by the diet. The rumination time presented a quadratic variation in relation to storage time of the hydrolyzed sugarcane, with higher values for the of hydrolyzed sugarcane diets stored for 48 hours. Heifers fed hydrolyzed sugarcane spent more time on other activities than those fed fresh sugarcane. The supply of hydrolyzed sugarcane stored up to 72 hours in the proportion of 600 g kg-1 of dry matter in the diet, alters the intake patterns, reducing the feed intake in Nellore heifers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A main purpose of a mathematical nutrition model (a.k.a., feeding systems) is to provide a mathematical approach for determining the amount and composition of the diet necessary for a certain level of animal productive performance. Therefore, feeding systems should be able to predict voluntary feed intake and to partition nutrients into different productive functions and performances. In the last decades, several feeding systems for goats have been developed. The objective of this paper is to compare and evaluate the main goat feeding systems (AFRC, CSIRO, NRC, and SRNS), using data of individual growing goat kids from seven studies conducted in Brazil. The feeding systems were evaluated by regressing the residuals (observed minus predicted) on the predicted values centered on their means. The comparisons showed that these systems differ in their approach for estimating dry matter intake (DMI) and energy requirements for growing goats. The AFRC system was the most accurate for predicting DMI (mean bias = 91 g/d, P < 0.001; linear bias 0.874). The average ADG accounted for a large part of the bias in the prediction of DMI by CSIRO, NRC, and, mainly, AFRC systems. The CSIRO model gave the most accurate predictions of ADG when observed DMI was used as input in the models (mean bias 12 g/d, P < 0.001; linear bias -0.229). while the AFRC was the most accurate when predicted DMI was used (mean bias 8g/d. P > 0.1; linear bias -0.347). (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A broca do cacho do coqueiro, Homalinotus coriaceus (Gyllenhal), é uma praga limitante da produção de coco no Brasil, sendo que tanto as larvas como os adultos provocam a queda das flores femininas e dos frutos imaturos, pela interceptação do fluxo de seiva ou pela alimentação direta nas estruturas reprodutivas. em virtude da escassez de informações sobre sua biologia, realizou-se esse trabalho com o objetivo de desenvolver uma metodologia mais adequada para a criação da praga em laboratório. Foram utilizados os parâmetros biológicos para avaliação e comparação dos sistemas de criação estudados.Toletes de cana-de-açúcar foram utilizados como substrato para alimentação dos adultos coletados no campo e obtenção dos ovos. As larvas foram criadas em três substratos alimentares no Laboratório de Entomologia da Empresa Brasileira de Pesquisa Agropecuária (EMBRAPA)-CPATC (Centro de Pesquisa Agropecuária dos Tabuleiros Costeiros), em Aracaju, SE. Os substratos alimentares estudados foram: o mesocarpo do coco, dieta para criação da broca dos citros e dieta para criação da broca do olho do coqueiro, sendo esta a que proporcionou o melhor desenvolvimento larval num menor tempo, com boa viabilidade, maior facilidade no preparo e manutenção.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radial profiles are reported of average and rms temperature in a propane flame for the first, second, and third acoustic modes at four different axial positions above the burner in a Rijke-tube combustor. Selected plots of the power spectral density (PSD) of temperature fluctuations are also reported. These radial profiles are then compared to similar ones made in the same flame, but in the absence of the acoustic field. Visual observations and photographs of the flame showed a remarkable change in flame height and structure with the onset of acoustic oscillations. This reduction in flame length, caused by the enhanced mixing due to the acoustic velocity fluctuations, gave rise to higher and lower average and rms temperatures near or well above the burner, respectively. In general, the PSD plots had a broad frequency content. The general trend was a decrease in magnitude with an increase in frequency. All cases presented broad-band peaks at around 5 Hz related to the flame flickering phenomenon. Preferred frequencies were observed in the oscillating PSD plots related to the fundamental frequency as well as subharmonics in the tube. (C) 2000 Elsevier B.V. Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A procedure for calculation of refrigerant mass flow rate is implemented in the distributed numerical model to simulate the flow in finned-tube coil dry-expansion evaporators, usually found in refrigeration and air-conditioning systems. Two-phase refrigerant flow inside the tubes is assumed to be one-dimensional, unsteady, and homogeneous. In themodel the effects of refrigerant pressure drop and the moisture condensation from the air flowing over the external surface of the tubes are considered. The results obtained are the distributions of refrigerant velocity, temperature and void fraction, tube-wall temperature, air temperature, and absolute humidity. The finite volume method is used to discretize the governing equations. Additionally, given the operation conditions and the geometric parameters, the model allows the calculation of the refrigerant mass flow rate. The value of mass flow rate is computed using the process of parameter estimation with the minimization method of Levenberg-Marquardt minimization. In order to validate the developed model, the obtained results using HFC-134a as a refrigerant are compared with available data from the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study Objectives: To study endotracheal tube (ETT) cuff pressures during nitrous oxide (N2O) anesthesia when the cuffs are inflated with air to achieve sealing pressure, and to evaluate the frequency of postoperative laryngotracheal complaints.Design: Prospective, randomized, blind study.Setting: Metropolitan teaching hospital.Patients: 50 ASA physical status I and II patients scheduled for elective abdominal surgery.Interventions: Patients received standard general anesthesia with 66% N2O in oxygen. In 25 patients, the ETT cuff was inflated with air to achieve a sealing pressure (P-seal group). In 25 patients, the ETT cuff was inflated with air to achieve a pressure of 25 cm H2O (P-25 group).Measurements and Main Results: ETT intracuff pressures were recorded before (control) and at 30, 60, 90, 120, and 150 minutes during N2O administration. We investigated the frequency and intensity of sore throat, hoarseness, and dysphagia in patients in the Post-Anesthesia Care Unit (PACU) and 24 hours following tracheal extubation. The cuff pressures in the P-seal group were significantly lower than in the P-25 group at all time points studied (p < 0.001), with a significant increase with time in both groups (p < 0.001). The cuff pressures exceeded the critical pressure of 30 cm H2O only after 90 minutes in the P-seal group and already by 30 minutes in the P-25 group. The frequency and intensity of sore throat, hoarseness, and dysphagia were similar in both groups in the PACU and 24 hours after tracheal extubation (p > 0.05).Conclusions: Minimum ETT sealing cuff pressure during N2O anesthesia did not prevent, but instead attenuated, the increase in cuff pressure and did not decrease postoperative laryngotracheal complaints. (C) 2004 by Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXTO E OBJETIVO: Os tubos traqueais são dispositivos utilizados para manutenção da ventilação. A hiperinsuflação do balonete do tubo traqueal, causada pela difusão do óxido nitroso (N2O), pode determinar lesões traqueais, que se manifestam clinicamente como odinofagia, rouquidão e tosse. A lidocaína, quando injetada no balonete do tubo traqueal, difunde-se através de sua parede, determinando ação anestésica local na traquéia. O objetivo foi avaliar a efetividade e a segurança do balonete do tubo traqueal preenchido com ar comparado com o balonete preenchido com lidocaína, considerando os desfechos: sintomas cardiovasculatórios (HAS, taquicardia); odinofagia, tosse, rouquidão e tolerância ao tubo traqueal. TIPO DE ESTUDO E LOCAL: Estudo clínico prospectivo, realizado no Departamento de Anestesiologia da Faculdade de Medicina da Unesp, campus de Botucatu. MÉTODOS: A pressão do balonete do tubo traqueal foi medida, entre 50 pacientes, antes, 30, 60, 90 e 120 minutos após o início da inalação de N2O anestésico. As pacientes foram distribuídas aleatoriamente em dois grupos: Air, em que o balonete foi inflado com ar para obtenção de pressão de 20 cm H2O, e Lido, em que o balonete foi preenchido com lidocaína a 2% mais bicarbonato de sódio a 8,4% para obtenção da mesma pressão. O desconforto antes da extubação, e manifestações clínicas como dor de garganta, rouquidão e tosse foram registrados no momento da alta da unidade de cuidados pós-anestésicos, e dor de garganta e rouquidão foram avaliadas também 24 horas após a anestesia. RESULTADOS: Os valores da pressão no balonete em G2 foram significativamente menores do que os de Air em todos os tempos de estudo, a partir de 30 minutos (p < 0,001). A proporção de pacientes que reagiu ao tubo traqueal no momento da desintubação foi significantemente menor em Lido (p < 0,005). A incidência de odinofagia foi significantemente menor em Lido no primeiro dia de pós-operatório (p < 0,05). A incidência de tosse e rouquidão não diferiu entre os grupos. CONCLUSÕES: Durante ventilação artificial, empregando-se a mistura de oxigênio e N2O, a insuflação do balonete com lidocaína 2% alcalinizada impede que ocorra aumento significante da pressão no balonete e determina maior tolerância ao tubo traqueal e menor incidência de odinofagia no pós-operatório, podendo então ser considerada mais segura e com maior efetividade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: To physiologically reconstruct the biliary tract, Crema et al suggested the application of the Monti principle to the biliary tract, already used in humans for the urinary tract. With this technique, a jejunal segment is transversely retubularized. This study aimed to evaluate the efficacy of jejunal tube interposition between the common bile duct and duodenum in dogs.METHODS: Thirteen dogs underwent a laparoscopic common bile duct ligature, followed by a biliodigestive connection by jejunal tube interposition after one week. The levels of glutamic-pyruvic and glutamic-oxalacetic transaminases, total bilirubins, alkaline phosphatase and gamma-glutamyltransferase were assessed before surgery and thereafter weekly until euthanasia, which was performed 6 weeks after biliodigestive connection.RESULTS: Data on 9 dogs were analyzed statistically. The dogs presented with obstructive jaundice after common bile duct ligature, as confirmed by biochemical examination. They showed a statistically significant reduction in cholestasis after biliodigestive connection by jejunal tube interposition and were healthy until the end of the experiment.CONCLUSION: A statistically significant reduction was seen in total bilirubin and canalicular enzymes (alkaline phosphatase and gamma-glutamyltransferase) in the 9 dogs 6 weeks after biliodigestive conviction by jejunal tube interposition.