57 resultados para Electronic data processing -- Quality control


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the absence of the selective availability, which was turned off on May 1, 2000, the ionosphere can be the largest source of error in GPS positioning and navigation. Its effects on GPS observable cause a code delays and phase advances. The magnitude of this error is affected by the local time of the day, season, solar cycle, geographical location of the receiver and Earth's magnetic field. As it is well known, the ionosphere is the main drawback for high accuracy positioning, when using single frequency receivers, either for point positioning or relative positioning of medium and long baselines. The ionosphere effects were investigated in the determination of point positioning and relative positioning using single frequency data. A model represented by a Fourier series type was implemented and the parameters were estimated from data collected at the active stations of RBMC (Brazilian Network for Continuous Monitoring of GPS satellites). The data input were the pseudorange observables filtered by the carrier phase. Quality control was implemented in order to analyse the adjustment and to validate the significance of the estimated parameters. Experiments were carried out in the equatorial region, using data collected from dual frequency receivers. In order to validate the model, the estimated values were compared with ground truth. For point and relative positioning of baselines of approximately 100 km, the values of the discrepancies indicated an error reduction better than 80% and 50% respectively, compared to the processing without the ionospheric model. These results give an indication that more research has to be done in order to provide support to the L1 GPS users in the Equatorial region.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Compact Muon Solenoid (CMS) detector is described. The detector operates at the Large Hadron Collider (LHC) at CERN. It was conceived to study proton-proton (and lead-lead) collisions at a centre-of-mass energy of 14 TeV (5.5 TeV nucleon-nucleon) and at luminosities up to 10(34)cm(-2)s(-1) (10(27)cm(-2)s(-1)). At the core of the CMS detector sits a high-magnetic-field and large-bore superconducting solenoid surrounding an all-silicon pixel and strip tracker, a lead-tungstate scintillating-crystals electromagnetic calorimeter, and a brass-scintillator sampling hadron calorimeter. The iron yoke of the flux-return is instrumented with four stations of muon detectors covering most of the 4 pi solid angle. Forward sampling calorimeters extend the pseudo-rapidity coverage to high values (vertical bar eta vertical bar <= 5) assuring very good hermeticity. The overall dimensions of the CMS detector are a length of 21.6 m, a diameter of 14.6 m and a total weight of 12500 t.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Profilometry by electronic speckle pattern interferometry with multimode diode lasers is both theoretically and experimentally studied. The multiwavelength character of the laser emission provides speckled images covered with interference fringes corresponding to the surface relief in single-exposure processes. For fringe pattern evaluation, variations of the phase-stepping technique are investigated for phase mapping as a function of the number of laser modes. Expressions for two, three, and four modes in four and eight stepping are presented, and the performances of those techniques are compared in the experiments through the surface shaping of a flat bar. The surface analysis of a peach points out the possibility of applying the technique in the quality control of food production and agricultural research. (c) 2007 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The number and the main groups of microorganisms present in samples of different nonalcoholic carbonated beverages (lemon, orange and guaraná soft drinks) obtained from a small factory were analyzed. The samples were obtained at the end of the processing line. They were then divided into two lots: one was sent to immediate analysis, the other was stored at environmental temperature for 90 d thereafter it was submitted to the same analysis. Aliquots of 1 mL were drawn from the various samples and the corresponding decimal dilutions were prepared. They were then grown in culture media and counts of mesophilic aerobic bacteria, molds and yeasts, acid-producing bacteria, total and fecal coliforms were taken. It was observed that, of all the analyzed samples, at time 0 or after storage sample C (orange) was the best, since it conformed to the microbiological standards established by legislation. The guaraná type could also be consumed on day zero; the lemon type was inadequate for consumption of all the analyzed samples, the orange type was the only one that could be consumed within 3 months of storage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Isotope screening is a simple test for determining the photosynthetic pathway used by plants. The scope of this work was to classify the photosynthetic type of some herbs and medicinal plants through studies of the carbon isotope composition (δ13C). Also, we propose the use of carbon isotope composition as a tool to control the quality of herbs and medicinal plants. For studies of δ13C, δ 13C‰ = [R (sample)/R (standard) - 1] × 10-3, dry leaves powdered in cryogenic mill were analyzed in a mass spectrometer coupled with an elemental analyzer for determining the ratio R = 13CO2/12CO2. In investigation of δ13C of 55 species, 23 botanical families, and 44 species possessed a C3 photosynthetic type. Six species found among the botanical families Euphorbiaceae and Poaceae were C4 plants, and 5 species found among the botanical families Agavaceae, Euphorbiaceae, and Liliaceae possessed CAM-type photosynthesis. Carbon isotope composition of plants can be used as quality control of herbs and medicinal plants, allowing the identification of frauds or contaminations. Also, the information about the photosynthetic type found for these plants can help in introducing and cultivating exotic and wild herbs and medicinal plants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Compositional data from 152 stingless bee (Meliponini) honey samples were compiled from studies since 1964, and evaluated to propose a quality standard for this product. Since stingless bee honey has a different composition than Apis mellifera honey, some physicochemical parameters are presented according to stingless bee species. The entomological origin of the honey was known for 17 species of Meliponini from Brazil, one from Costa Rica, six from Mexico, 27 from Panama, one from Surinam, two from Trinidad & Tobago, and seven from Venezuela, most from the genus Melipona. The results varied as follows: moisture (19.9-41.9g/100g), pH (3.15-4.66), free acidity (5.9-109.0meq/Kg), ash (0.01-1.18g/100g), diastase activity (0.9-23.0DN), electrical conductivity (0.49-8.77mS/cm), HMF (0.4-78.4mg/Kg), invertase activity (19.8-90.1IU), nitrogen (14.34-144.00mg/100g), reducing sugars (58.0-75.7g/100g) and sucrose (1.1-4.8g/100g). Moisture content of stingless bee honey is generally higher than the 20% maximum established for A. mellifera honey. Guidelines for further contributions would help make the physicochemical database of meliponine honey more objective, in order to use such data to set quality standards. Pollen analysis should be directed towards the recognition of unifloral honeys produced by stingless bees, in order to obtain standard products from botanical species. A honey quality control campaign directed to both stingless beekeepers and stingless bee honey hunters is needed, as is harmonization of analytical methods. © 2007 Asociación Interciencia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Until mid 2006, SCIAMACHY data processors for the operational retrieval of nitrogen dioxide (NO2) column data were based on the historical version 2 of the GOME Data Processor (GDP). On top of known problems inherent to GDP 2, ground-based validations of SCIAMACHY NO2 data revealed issues specific to SCIAMACHY, like a large cloud-dependent offset occurring at Northern latitudes. In 2006, the GDOAS prototype algorithm of the improved GDP version 4 was transferred to the off-line SCIAMACHY Ground Processor (SGP) version 3.0. In parallel, the calibration of SCIAMACHY radiometric data was upgraded. Before operational switch-on of SGP 3.0 and public release of upgraded SCIAMACHY NO2 data, we have investigated the accuracy of the algorithm transfer: (a) by checking the consistency of SGP 3.0 with prototype algorithms; and (b) by comparing SGP 3.0 NO2 data with ground-based observations reported by the WMO/GAW NDACC network of UV-visible DOAS/SAOZ spectrometers. This delta-validation study concludes that SGP 3.0 is a significant improvement with respect to the previous processor IPF 5.04. For three particular SCIAMACHY states, the study reveals unexplained features in the slant columns and air mass factors, although the quantitative impact on SGP 3.0 vertical columns is not significant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Due to growing urbanization and industrialization, the environment is suffering from pollution of rivers, degradation of soils and deteriorated air quality. Quality indices appear to be useful to evaluate the conditions of these media. The aim of this study was the development of a water quality index using a fuzzy inference system, since such an approach has proved advantageous in addressing problems that are subjective by nature or for which the data are uncertain. The methodology employed was based on this inference system, and considered the nine water quality parameters employed by CETESB (Companhia de Tecnologia de Saneamento Ambiental, São Paulo, Brazil) to evaluate water quality. After assessment of the data using the index, a comparison was made with the WQI (Water Quality Index), which is used for the monitoring of various water bodies, including in the study region. The results obtained using the index developed on the basis of fuzzy inference were found to be more useful than those derived from the method currently used by CETESB, since losses and/or omissions concerning individual parameters were minimized. © 2010 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In geophysics and seismology, raw data need to be processed to generate useful information that can be turned into knowledge by researchers. The number of sensors that are acquiring raw data is increasing rapidly. Without good data management systems, more time can be spent in querying and preparing datasets for analyses than in acquiring raw data. Also, a lot of good quality data acquired at great effort can be lost forever if they are not correctly stored. Local and international cooperation will probably be reduced, and a lot of data will never become scientific knowledge. For this reason, the Seismological Laboratory of the Institute of Astronomy, Geophysics and Atmospheric Sciences at the University of São Paulo (IAG-USP) has concentrated fully on its data management system. This report describes the efforts of the IAG-USP to set up a seismology data management system to facilitate local and international cooperation. © 2011 by the Istituto Nazionale di Geofisica e Vulcanologia. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The microbiological control of moisturizing mask formulation added of hibiscus flowers, assai palm, black mulberry and papaw glycolic extracts, determining the number of viable microorganisms and possible presence of pathogenic. The moisturizing mask formulation was composed of zinc oxide (5. 0%) and moisturizing cream constituted of triceteareth-4 phosphate (and) cetyl alcohol (and) stearyl alcohol (and) sodium cetearyl sulfate (and) oleth-10 (qs 50g). To this formulation was added hibiscus flowers glycolic extract (2. 5%), assai palm glycolic extract (1. 5%), black mulberry glycolic extract (1. 5%) and papaw glycolic extract (2. 0%). The formulation was stored in aseptically clean recipients, away from humidity and light, in fresh and airy places. The results of the microbiological analysis on the counting of aerobic mesophilic microorganisms (bacteria and fungi), of the above mentioned formulation, revealed a bioburden < 10 CFU/mL in all samples. Such data indicate adequate microbiological quality of the tested products, according to official recommendations. Furthermore, it was not detected the presence of pathogenic microorganisms, assuring the harmlessness of the formulation. The results lead us to conclude that the formulation and raw materials analyzed did not present microbial contamination, evidenced for estimating the number of viable microorganisms (<10 UFC/g) and for researching pathogens.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)