178 resultados para Electric units.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports dielectric measurements performed on Pb(Zr0.53Ti0.47)O3 (PZT) thin films prepared by a polymeric precursor method. The -E curves obtained for the PZT film measured at 100 kHz, under a small ac 0.2 kV/cm signal-test and a dc scan featured a typical butterfly curve. However, the -E curves obtained for PZT film under a dc scan, with a scan rate of 0.003 V/s, shows a pronounced asymmetry. The absence of a symmetric secondary peak in -E curves could be an indication of essentially 180 domain switching.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: A separação de gêmeos unidos causa grande interesse devido à complexidade da anestesia e cirurgia, à raridade da patologia e às poucas chances de sobrevida. O objetivo desta descrição é o de contribuir para a literatura existente, relatando os desafios encontrados por nossa equipe no atendimento à cirurgia-anestesia de separação de gêmeos isquiópagos. RELATO do CASO: Pacientes gêmeos, nascidos a termo, de parto cesariano, pesando juntos 5.100 g, classificados como isquiópagus tetrapus. Duas equipes anestésico-cirúrgicas estavam presentes, sendo o procedimento anestésico esquematizado com aparelho de anestesia, cardioscópio, capnógrafo, oxímetro de pulso, termômetro elétrico, estetoscópio esofágico, todos em dobro. Realizou-se indução anestésica com halotano e fentanil, com os gêmeos em posição lateral e com rotação da cabeça em 45º para facilitar a intubação traqueal. Os recém-nascidos foram mantidos em ventilação controlada manualmente, utilizando o sistema de Rees-Baraka. A anestesia foi mantida com halotano, oxigênio e fentanil. Durante o per-operatório, foram encontrados órgãos abdominais duplos, com exceção do cólon, que era único. As bexigas e os ísquios estavam ligados. Ao final da cirurgia as duas crianças apresentavam-se com sinais vitais estáveis. Os gêmeos permaneceram na Unidade de Terapia Intensiva (UTI) Neonatal por quatro semanas e receberam alta em bom estado geral. CONCLUSÕES: Ressalta-se a importância do entrosamento da equipe, do estudo retrospectivo multidisciplinar, da monitorização adequada e acurada observação clínica; todos esses fatores contribuíram para a boa evolução e alta dos gêmeos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The transmission of influenza in health care settings is a major threat to patients, especially those with severe diseases. The attitude of health care workers (HCWs) may influence the transmission of countless infections. The current study aimed to quantify knowledge and identify attitudes of HCWs involved in intensive care units (ICUs) regarding the risk of nosocomial influenza transmission. A questionnaire was applied through interviews to HCWs who worked in one of the five ICUs from a teaching hospital. Questions about influenza were deliberately dispersed among others that assessed several infectious agents. Forty-two HCWs were interviewed: nine physicians, ten nurses and 23 nursing technicians or auxiliaries. Among the 42 HCWs, 98% were aware of the potential transmission of influenza virus in the ICUs, but only 31% would indicate droplet precautions for patients with suspected infection. Moreover, only 31% of them had been vaccinated against influenza in the last campaign (2008). Nursing technicians or auxiliaries were more likely to have been vaccinated, both by univariate and multivariable analysis. When asked about absenteeism, only 10% of the study subjects stated that they would not go to work if they had an influenza-like illness. Those findings suggest that, in non-pandemic periods, influenza control in hospitals requires strategies that combine continuous education with changes in organizational culture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the polymerization effectiveness of a composite resin (Z-250) utilizing microhardness testing. In total, 80 samples with thicknesses of 2 and 4 mm were made, which were photoactivated by a conventional halogen light-curing unit, and light-curing units based on LED. The samples were stored in water distilled for 24 h at 37C. The Vickers microhardness was performed by the MMT-3 microhardness tester. The microhardness means obtained were as follows: G1, 72.88; G2, 69.35; G3, 67.66; G4, 69.71; G5, 70.95; G6, 75.19; G7, 72.96; and G8, 71.62. The data were submitted to an analysis of variance (ANOVA's test), adopting a significance level of 5%. The results showed that, in general, there were no statistical differences between the halogen and LED light-curing units used with the same parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to determine the effect of two light-curing units (QTH and LED) on microleakage of Class II composite resin restorations with dentin cavosurface margins. Twenty extracted mandibular first premolars, free of caries and fractures were prepared two vertical slot cavities in the occluso-mesial and -destal surfaces (2 mm buccal-lingually, 2 mm proximal-axially and cervical limit in enamel) and divided into 4 equal groups (n = 8): GI and GII: packable posterior composite light-activated with LED and QTH, respectively; GIII and GIV: micro-hybrid composite resin light-activated with LED and QTH, respectively. The composite resins were applied following the manufacturer's instructions. After 24 h of water storage specimens were subjected to thermocycling for a total of 500 cycles at 5 and 55A degrees C and the teeth were then sealed with impermeable material. Teeth were immersed in 0.5% Basic fuchsin during 24 h at room temperature, and zero to three levels of penetration score were attributed. The Mann-Whitney and Kruskal-Wallis tests showed significant statistically similar (P > 0.05) from GI to GII and GIII to GIV, which the GII (2.750) had the highest mean scores and the GIII and GIV (0.875) had lowest mean scores. The use of different light-curing units has no influence on marginal integrity of Class II composite resin restorations and the proprieties of composite resins are important to reduce the microleakage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In higher eukaryotes, the 5S ribosomal DNA (5S rDNA) is organized in tandem arrays with repeat units composed of a coding region and a non-transcribed spacer sequence (NTS). These tandem arrays can be found on either one or more chromosome pairs. 5S rDNA copies from the tilapia fish. Oreochromis niloticus, were cloned and the nucleotide sequences of the coding region and of the non-transcribed spacer were deter-mined. Moreover, the genomic organization of the 5S rDNA tandem repeats was investigated by fluorescence in situ hybridization (FISH) and Southern blot hybridization. Two 5S rDNA classes, one consisting of 1.4-kb repeats and another one with 0.5-kb repeats were identified and designated 5S rDNA type I and type II, respectively, An inverted 5S rRNA gene and a 5S rRNA putative pseudogene were also identified inside the tandem repeats of 5S rDNA type I. FISH permitted the visualization of the 5S rRNA genes at three chromosome loci, one of them consisting of arrays of the 5S rDNA type I, and the two others corresponding to arrays of the 5S rDNA type II. The two classes of the 5S rDNA. The presence of pseudogenes, and the inverted genes observed in the O. niloticus genome might be a consequence of the intense dynamics of the evolution of these tandem repeat elements. Copyright (C) 2002 S. Karger AG, Basel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An early stage of sex chromosome differentiation is reported to occur in the electric eel Eigenmannia virescens (Pisces, Sternopygidae) from populations of two tributaries of the Parana river system (Brazil). Cytogenetic studies carried out in the two populations showed that the Mogi-Guacu population is characterized by 2n = 38 chromosomes and undifferentiated sex chromosomes and the Tiete population presents 2n = 38 both for males and females and an XX:XY sex chromosome system. The X-chromosome is acrocentric, easily recognized by the presence of a conspicuous heterochromatin block in its distal portion; the Y-chromosome is probably one of the medium sized acrocentrics present in the male karyotype. BrdU induced R-bands of the two populations did not reveal any difference in the euchromatic regions of the chromosomes. AluI and HaeIII restriction enzyme digestion patterns and chromomycin A3 staining of the X-chromosome are presented. The possible role of heterochromatinization in the evolution of sex chromosomes in fish is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This study evaluated the surface hardness of a resin cement (RelyX ARC) photoactivated through indirect composite resin (Cristobal) disks of different thicknesses using either a light- emitting diode (LED) or quartz tungsten halogen (QTH) light source. Material and Methods: Eighteen resin cement specimens were prepared and divided into 6 groups according to the type of curing unit and the thickness of resin disks interposed between the cement surface and light source. Three indentations (50 g for 15 s) were performed on the top and bottom surface of each specimen and a mean Vickers hardness number (VHN) was calculated for each specimen. The data were analyzed using two-way ANOVA and Tukey-Kramer test was used for post-hoc pairwise comparisons. Results: Increased indirect resin disk thickness resulted in decreased mean VHN values. Mean VHN values for the top surfaces of the resin cement specimens ranged from 23.2 to 46.1 (QTH) and 32.3 to 41.7 (LED). The LED curing light source produced higher hardness values compared to the QTH light source for 2- and 3-mm-thick indirect resin disks. The differences were clinically, but not statistically significant. Increased indirect resin disk thickness also resulted in decreased mean VHN values for the bottom surfaces of the resin cement: 5.8 to 19.1 (QTH) and 7.5 to 32.0 (LED). For the bottom surfaces, a statistically significant interaction was also found between the type of curing light source and the indirect resin disk thickness. Conclusions: Mean surface hardness values of resin cement specimens decreased with the increase of indirect resin disk thickness. The LED curing light source generally produced higher surface hardness values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate some proposals to solve the electric charge quantization puzzle that simultaneously explain the recent measured deviation on the muon anomalous magnetic moment. For this we assess extensions of the electro-weak standard model spanning modifications on the scalar sector only. It is interesting to verify that one can have modest extensions which easily account for the solution for both problems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)